Narrative review: evolution in device technology and advances in surgical techniques on AMS 800 device in the last 50 years.

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Accounts of Chemical Research Pub Date : 2024-08-31 Epub Date: 2024-04-26 DOI:10.21037/tau-23-10
Eric Chung
{"title":"Narrative review: evolution in device technology and advances in surgical techniques on AMS 800 device in the last 50 years.","authors":"Eric Chung","doi":"10.21037/tau-23-10","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>The current AMS 800 artificial urinary sphincter (AUS) device is designed to simulate the function of the biological urinary sphincter to prevent urinary flow through mucosal coaptation, compression, and pressure transmission. The challenges in designing the AMS 800 device involve not only the mechanical operation of the artificial sphincter device but also producing a device that is effective, safe, and durable for patients in the long term. The following article provides a narrative review regarding the evolution and development of the AMS 800 devices over the years and evaluates the advances in surgical techniques relating to AMS 800 implantation.</p><p><strong>Methods: </strong>Available literature pertaining to the AMS 800 device was reviewed from the MEDLINE and EMBASE databases between 1 January 2000 to 31 December 2022. Emphasis is placed on key scientific publications including previous reviews and clinical guidelines relevant to AMS 800 device(s) and surgical techniques.</p><p><strong>Key content and findings: </strong>From the engineering point of view, the current AMS 800 device is ingenious and has stood the test of time. The basic design of this modern AUS consists of 3 separate components namely a pressure regulating balloon (PRB), an inflatable cuff, and a control pump. Continued innovations in device design and technology, coupled with refinements in surgical techniques over the past 5 decades have ensured that the AMS 800 device is and remains the standard of care in male stress urinary incontinence. While the long-term AMS 800 efficacy, safety, and durability are well documented, it is not without its limitations and complications. Mechanical and non-mechanical complications can occur especially in high-risk populations (such as in radiated patients) despite strict adherence to surgical principles and manufacturer's guidelines.</p><p><strong>Conclusions: </strong>Continued innovations in device design, technology, and surgical techniques have ensured that the AMS 800 device is an effective and safe treatment for male stress urinary incontinence (SUI). Future directions in the treatment of male SUI likely reside in cellular regenerative therapy and nanotechnology to restore, replace, or simulate the damaged native urinary sphincter.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11399039/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/tau-23-10","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objective: The current AMS 800 artificial urinary sphincter (AUS) device is designed to simulate the function of the biological urinary sphincter to prevent urinary flow through mucosal coaptation, compression, and pressure transmission. The challenges in designing the AMS 800 device involve not only the mechanical operation of the artificial sphincter device but also producing a device that is effective, safe, and durable for patients in the long term. The following article provides a narrative review regarding the evolution and development of the AMS 800 devices over the years and evaluates the advances in surgical techniques relating to AMS 800 implantation.

Methods: Available literature pertaining to the AMS 800 device was reviewed from the MEDLINE and EMBASE databases between 1 January 2000 to 31 December 2022. Emphasis is placed on key scientific publications including previous reviews and clinical guidelines relevant to AMS 800 device(s) and surgical techniques.

Key content and findings: From the engineering point of view, the current AMS 800 device is ingenious and has stood the test of time. The basic design of this modern AUS consists of 3 separate components namely a pressure regulating balloon (PRB), an inflatable cuff, and a control pump. Continued innovations in device design and technology, coupled with refinements in surgical techniques over the past 5 decades have ensured that the AMS 800 device is and remains the standard of care in male stress urinary incontinence. While the long-term AMS 800 efficacy, safety, and durability are well documented, it is not without its limitations and complications. Mechanical and non-mechanical complications can occur especially in high-risk populations (such as in radiated patients) despite strict adherence to surgical principles and manufacturer's guidelines.

Conclusions: Continued innovations in device design, technology, and surgical techniques have ensured that the AMS 800 device is an effective and safe treatment for male stress urinary incontinence (SUI). Future directions in the treatment of male SUI likely reside in cellular regenerative therapy and nanotechnology to restore, replace, or simulate the damaged native urinary sphincter.

叙述性回顾:过去 50 年中设备技术的演变和 AMS 800 设备手术技术的进步。
背景和目的:目前的 AMS 800 人工尿道括约肌(AUS)装置旨在模拟生物尿道括约肌的功能,通过粘膜粘合、压缩和压力传递来防止尿液流出。设计 AMS 800 装置所面临的挑战不仅包括人工括约肌装置的机械操作,还包括为患者生产一种长期有效、安全和耐用的装置。以下文章对 AMS 800 装置多年来的演变和发展进行了叙述性回顾,并评估了与 AMS 800 植入相关的手术技术的进步:方法:从 2000 年 1 月 1 日至 2022 年 12 月 31 日期间的 MEDLINE 和 EMBASE 数据库中查阅了与 AMS 800 装置有关的现有文献。重点放在主要的科学出版物上,包括与 AMS 800 装置和手术技术相关的以往综述和临床指南:从工程学的角度来看,目前的 AMS 800 设备独具匠心,经受住了时间的考验。这种现代 AUS 的基本设计由 3 个独立部件组成,即压力调节球囊 (PRB)、充气罩囊和控制泵。在过去的 50 年中,设备设计和技术的不断创新,加上手术技术的不断改进,确保了 AMS 800 设备一直是治疗男性压力性尿失禁的标准设备。虽然 AMS 800 的长期疗效、安全性和耐用性有据可查,但它也并非没有局限性和并发症。尽管严格遵守手术原则和制造商的指导方针,但机械和非机械并发症仍可能发生,尤其是在高风险人群(如放射性患者)中:设备设计、技术和手术技巧的不断创新确保了 AMS 800 设备是治疗男性压力性尿失禁(SUI)的有效而安全的方法。治疗男性压力性尿失禁的未来方向可能在于细胞再生疗法和纳米技术,以恢复、替代或模拟受损的原生尿道括约肌。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信