INTDOSKIT: An R-Code for Calculation of Dose Coefficients and Studying Their Uncertainties.

IF 1 4区 医学 Q4 ENVIRONMENTAL SCIENCES
Bastian Breustedt, Niranjan Chavan, Thomas Makumbi
{"title":"INTDOSKIT: An R-Code for Calculation of Dose Coefficients and Studying Their Uncertainties.","authors":"Bastian Breustedt, Niranjan Chavan, Thomas Makumbi","doi":"10.1097/HP.0000000000001833","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>An R-code, which allows the calculation of the time dependent activity distribution based on ICRP reference models, the number of decays in a commitment period, and the dose coefficients for tissues and organs of the human body, has been developed. R Language was chosen due to its powerful mathematical and statistical modeling features, as well as its graphical capabilities. The developed set of functions and constants (called \"INTDOSKIT\") can be sourced in R-scripts that define or import the models and calculations to be performed. The code has been tested on models of several radionuclides and was successfully validated against reference data taken from ICRP OIR Data Viewer software. Furthermore, the code has been tested and verified on the modeling of the radioactivity of decay chains using data of the 233Ra model presented by Höllriegl and colleagues. The results of calculations with INTDOSKIT demonstrated that the code is able to reproduce the ICRP bioassay data and dose coefficients. Deviations are a few percent only and are due mainly to rounding in the original data. Lastly, the code is able to handle uncertainty and sensitivity studies as demonstrated by the results in a pilot study of injection of 241Am, which estimated geometric standard deviations (GSD) for dose coefficients ranging between 1.25 (bone-surface) and 1.66 (testes); these results are consistent with those obtained from similar studies done by other researchers who reported GSD values ranging from 1.13 to 1.73.</p>","PeriodicalId":12976,"journal":{"name":"Health physics","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HP.0000000000001833","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract: An R-code, which allows the calculation of the time dependent activity distribution based on ICRP reference models, the number of decays in a commitment period, and the dose coefficients for tissues and organs of the human body, has been developed. R Language was chosen due to its powerful mathematical and statistical modeling features, as well as its graphical capabilities. The developed set of functions and constants (called "INTDOSKIT") can be sourced in R-scripts that define or import the models and calculations to be performed. The code has been tested on models of several radionuclides and was successfully validated against reference data taken from ICRP OIR Data Viewer software. Furthermore, the code has been tested and verified on the modeling of the radioactivity of decay chains using data of the 233Ra model presented by Höllriegl and colleagues. The results of calculations with INTDOSKIT demonstrated that the code is able to reproduce the ICRP bioassay data and dose coefficients. Deviations are a few percent only and are due mainly to rounding in the original data. Lastly, the code is able to handle uncertainty and sensitivity studies as demonstrated by the results in a pilot study of injection of 241Am, which estimated geometric standard deviations (GSD) for dose coefficients ranging between 1.25 (bone-surface) and 1.66 (testes); these results are consistent with those obtained from similar studies done by other researchers who reported GSD values ranging from 1.13 to 1.73.

INTDOSKIT:用于计算剂量系数和研究其不确定性的 R 代码。
摘要:我们开发了一种 R 代码,可以根据国际放射防护委员会的参考模型计算随时间变化的放射性活度分布、承诺期内的衰变次数以及人体组织和器官的剂量系数。之所以选择 R 语言,是因为它具有强大的数学和统计建模功能以及图形功能。开发的函数和常量集(称为 "INTDOSKIT")可在 R 脚本中使用,以定义或导入要执行的模型和计算。该代码已在几种放射性核素的模型上进行了测试,并成功地与来自 ICRP OIR Data Viewer 软件的参考数据进行了验证。此外,还利用 Höllriegl 及其同事提供的 233Ra 模型数据,对该代码进行了衰变链放射性建模测试和验证。使用 INTDOSKIT 计算的结果表明,该代码能够再现 ICRP 的生物测定数据和剂量系数。偏差仅为百分之几,主要是由于原始数据的四舍五入造成的。最后,该代码能够处理不确定性和敏感性研究,对注入 241Am 的试验研究结果证明了这一点,该研究估计剂量系数的几何标准偏差(GSD)在 1.25(骨表面)和 1.66(睾丸)之间;这些结果与其他研究人员进行的类似研究得出的结果一致,其他研究人员报告的 GSD 值在 1.13 至 1.73 之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Health physics
Health physics 医学-公共卫生、环境卫生与职业卫生
CiteScore
4.20
自引率
0.00%
发文量
324
审稿时长
3-8 weeks
期刊介绍: Health Physics, first published in 1958, provides the latest research to a wide variety of radiation safety professionals including health physicists, nuclear chemists, medical physicists, and radiation safety officers with interests in nuclear and radiation science. The Journal allows professionals in these and other disciplines in science and engineering to stay on the cutting edge of scientific and technological advances in the field of radiation safety. The Journal publishes original papers, technical notes, articles on advances in practical applications, editorials, and correspondence. Journal articles report on the latest findings in theoretical, practical, and applied disciplines of epidemiology and radiation effects, radiation biology and radiation science, radiation ecology, and related fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信