{"title":"Precise prediction of size of a foldable capsular vitreous body via computerized three-dimensional ocular reconstruction in severe retinal detachment.","authors":"Chongde Long, Qianying Gao, Shenwen Liu, Yan Chen, Huping Song, Jinguo Yu, Bingsheng Lou, Zhaohui Yuan, Yongxin Zheng, Liuxueying Zhong, Siqi Qiao, Xiangda Meng, Yuanyuan Liu, Yingyu Wang, Yuanyuan Liu, Xiaofeng Lin, Hua Yan","doi":"10.1186/s12886-024-03646-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to precisely predict the size and silicone oil injection of a foldable capsular vitreous body (FCVB) via computerized three-dimensional (3D) ocular reconstruction in the treatment of severe retinal detachment in China.</p><p><strong>Methods: </strong>The 3D software Unigraphics NX was applied to determine the volume of the inner cavity with 16-30 mm axial length, assigning the anterior and posterior chambers, the FCVB sizes, and the silicone oil injection volume, and modeling the data between the axial length and the FCVB size. In clinical practice, IOL Master was applied to accurately measure the axial length of the contralateral healthy eye to anchor the anterior-posterior and horizontal diameters of the operated eye in horizontal position CT, and compared with the model to recommend the FCVB size and silicone oil amount, and the clinical effect was validated in cases across five hospitals in China.</p><p><strong>Results: </strong>For the axial length of 16-30 mm, the volume of the inner cavity is 1.2 ml-8.4 ml. FCVB size and silicone oil volume were recommended based on this volume of the inner cavity. Of 253 cases, we noted 11 cases implanted with AV-10P and 1.05 ± 0.21 ml of silicone oil, 41 with AV-12P and 1.58 ± 0.18 ml of silicone oil, 163 with AV-13.5P and 2.48 ± 0.29 ml of silicone oil, 31 with AV-15P and 3.57 ± 0.39 ml of silicone oil, and 7 with AV-17P and 5.71 ± 0.81 ml of silicone oil. There was no significant difference in postoperative visual acuity scores compared with preoperative (P = 0.097), postoperative IOP(10.29 ± 0.57mmHg)was slightly higher than preoperative IOP (9.76 ± 0.48 mmHg), but there was still no statistically significant difference between the two comparisons (P = 0.405).</p><p><strong>Conclusion: </strong>Three-dimensional reconstruction prediction is a good solution for eyeballs with obvious individualized changes in severe retinal detachment, and this method helps doctors standardize FCVB size selection and the silicone oil amount for patients.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11414271/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-024-03646-9","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study aimed to precisely predict the size and silicone oil injection of a foldable capsular vitreous body (FCVB) via computerized three-dimensional (3D) ocular reconstruction in the treatment of severe retinal detachment in China.
Methods: The 3D software Unigraphics NX was applied to determine the volume of the inner cavity with 16-30 mm axial length, assigning the anterior and posterior chambers, the FCVB sizes, and the silicone oil injection volume, and modeling the data between the axial length and the FCVB size. In clinical practice, IOL Master was applied to accurately measure the axial length of the contralateral healthy eye to anchor the anterior-posterior and horizontal diameters of the operated eye in horizontal position CT, and compared with the model to recommend the FCVB size and silicone oil amount, and the clinical effect was validated in cases across five hospitals in China.
Results: For the axial length of 16-30 mm, the volume of the inner cavity is 1.2 ml-8.4 ml. FCVB size and silicone oil volume were recommended based on this volume of the inner cavity. Of 253 cases, we noted 11 cases implanted with AV-10P and 1.05 ± 0.21 ml of silicone oil, 41 with AV-12P and 1.58 ± 0.18 ml of silicone oil, 163 with AV-13.5P and 2.48 ± 0.29 ml of silicone oil, 31 with AV-15P and 3.57 ± 0.39 ml of silicone oil, and 7 with AV-17P and 5.71 ± 0.81 ml of silicone oil. There was no significant difference in postoperative visual acuity scores compared with preoperative (P = 0.097), postoperative IOP(10.29 ± 0.57mmHg)was slightly higher than preoperative IOP (9.76 ± 0.48 mmHg), but there was still no statistically significant difference between the two comparisons (P = 0.405).
Conclusion: Three-dimensional reconstruction prediction is a good solution for eyeballs with obvious individualized changes in severe retinal detachment, and this method helps doctors standardize FCVB size selection and the silicone oil amount for patients.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.