George S. Buijs , Arthur J. Kievit , Matthias U. Schafroth , Leendert Blankevoort
{"title":"An evaluation of the diagnostic performance of the triphasic bone scintigraphy in patients suspected of aseptic total knee arthroplasty loosening","authors":"George S. Buijs , Arthur J. Kievit , Matthias U. Schafroth , Leendert Blankevoort","doi":"10.1016/j.jor.2024.08.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Total Knee Arthroplasty (TKA) is a widely conducted and successful orthopedic procedure. However, aseptic loosening, a common cause of TKA failure, necessitates revision surgery. Diagnostic accuracy of triphasic bone scintigraphy, a common imaging modality for aseptic loosening detection, remains controversial. This study investigated the diagnostic accuracy of bone scintigraphy when separately evaluated by a nuclear physicist and an orthopedic surgeon, and the interrater reliability between the two.</p></div><div><h3>Methods</h3><p>Patients undergoing knee revision surgery due to suspected aseptic loosening at three medical centers from 2006 to 2023 were included. Relevant demographic, clinical, and procedural data were extracted from the records. The bone scintigraphy results as noted by the nuclear physicist and orthopedic surgeon were used as index test and intraoperative findings of loosening were used as reference tests. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were calculated, and kappa's agreement was assessed.</p></div><div><h3>Results</h3><p>Out of 611 revision TKAs, 59 cases were analyzed. The nuclear physicist's evaluation of bone scintigraphy had a sensitivity of 73 %, specificity of 0 %, positive predictive value of 93 %, negative predictive value of 0 %, and diagnostic accuracy of 69 %. The orthopedic surgeon's evaluation showed higher sensitivity, specificity, positive and negative predictive values, and an accuracy of 84 %. Agreement levels were moderate (kappa = 0.46) between the nuclear physicist's and orthopedic surgeons evaluation.</p></div><div><h3>Interpretation</h3><p>The diagnostic accuracy of bone scintigraphy for aseptic loosening is 84 % when evaluated by the orthopedic surgeon compared to 69 % for the nuclear physicist's evaluation. Kappa's agreement between the two was moderate.</p></div>","PeriodicalId":16633,"journal":{"name":"Journal of orthopaedics","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0972978X24002952/pdfft?md5=a118b756a26178a8c05386e5875eea88&pid=1-s2.0-S0972978X24002952-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0972978X24002952","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Total Knee Arthroplasty (TKA) is a widely conducted and successful orthopedic procedure. However, aseptic loosening, a common cause of TKA failure, necessitates revision surgery. Diagnostic accuracy of triphasic bone scintigraphy, a common imaging modality for aseptic loosening detection, remains controversial. This study investigated the diagnostic accuracy of bone scintigraphy when separately evaluated by a nuclear physicist and an orthopedic surgeon, and the interrater reliability between the two.
Methods
Patients undergoing knee revision surgery due to suspected aseptic loosening at three medical centers from 2006 to 2023 were included. Relevant demographic, clinical, and procedural data were extracted from the records. The bone scintigraphy results as noted by the nuclear physicist and orthopedic surgeon were used as index test and intraoperative findings of loosening were used as reference tests. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were calculated, and kappa's agreement was assessed.
Results
Out of 611 revision TKAs, 59 cases were analyzed. The nuclear physicist's evaluation of bone scintigraphy had a sensitivity of 73 %, specificity of 0 %, positive predictive value of 93 %, negative predictive value of 0 %, and diagnostic accuracy of 69 %. The orthopedic surgeon's evaluation showed higher sensitivity, specificity, positive and negative predictive values, and an accuracy of 84 %. Agreement levels were moderate (kappa = 0.46) between the nuclear physicist's and orthopedic surgeons evaluation.
Interpretation
The diagnostic accuracy of bone scintigraphy for aseptic loosening is 84 % when evaluated by the orthopedic surgeon compared to 69 % for the nuclear physicist's evaluation. Kappa's agreement between the two was moderate.
期刊介绍:
Journal of Orthopaedics aims to be a leading journal in orthopaedics and contribute towards the improvement of quality of orthopedic health care. The journal publishes original research work and review articles related to different aspects of orthopaedics including Arthroplasty, Arthroscopy, Sports Medicine, Trauma, Spine and Spinal deformities, Pediatric orthopaedics, limb reconstruction procedures, hand surgery, and orthopaedic oncology. It also publishes articles on continuing education, health-related information, case reports and letters to the editor. It is requested to note that the journal has an international readership and all submissions should be aimed at specifying something about the setting in which the work was conducted. Authors must also provide any specific reasons for the research and also provide an elaborate description of the results.