Feasibility of laser induced breakdown spectroscopy for quantification of zirconium in nuclear streams

IF 1.5 3区 化学 Q3 CHEMISTRY, ANALYTICAL
Satendra Kumar, S. Maji, K. Sundararajan
{"title":"Feasibility of laser induced breakdown spectroscopy for quantification of zirconium in nuclear streams","authors":"Satendra Kumar, S. Maji, K. Sundararajan","doi":"10.1007/s10967-024-09763-5","DOIUrl":null,"url":null,"abstract":"<p>Laser induced breakdown spectroscopy is explored for the estimation of Zr in metallic fuel and pyrochemical reprocessing stream using filter paper as a sample substrate. Zr(II) emission line at 339.20 nm has been identified and used for its quantitative determination. Calibration curves are obtained after normalizing the intensity of Zr to C/Y emission lines as an internal standard, to get better linearity. Analytical capability of LIBS for Zr estimation is tested by comparing the measured value with ICP-OES in simulated samples. Good agreement between the measured values confirms the ability of LIBS application in nuclear streams.</p>","PeriodicalId":661,"journal":{"name":"Journal of Radioanalytical and Nuclear Chemistry","volume":"50 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radioanalytical and Nuclear Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s10967-024-09763-5","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Laser induced breakdown spectroscopy is explored for the estimation of Zr in metallic fuel and pyrochemical reprocessing stream using filter paper as a sample substrate. Zr(II) emission line at 339.20 nm has been identified and used for its quantitative determination. Calibration curves are obtained after normalizing the intensity of Zr to C/Y emission lines as an internal standard, to get better linearity. Analytical capability of LIBS for Zr estimation is tested by comparing the measured value with ICP-OES in simulated samples. Good agreement between the measured values confirms the ability of LIBS application in nuclear streams.

Abstract Image

激光诱导击穿光谱法量化核气流中锆的可行性
使用滤纸作为样品基底,探索了激光诱导击穿光谱法来估算金属燃料和热化学后处理流中的锆含量。确定了 339.20 纳米波长的 Zr(II)发射线,并将其用于定量测定。将 Zr 的强度归一化为 C/Y 发射线作为内标,得到校准曲线,以获得更好的线性。通过比较模拟样品中的测量值与 ICP-OES 的测量值,测试了 LIBS 估算锆的分析能力。测量值之间的良好一致性证实了 LIBS 在核气流中的应用能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
18.80%
发文量
504
审稿时长
2.2 months
期刊介绍: An international periodical publishing original papers, letters, review papers and short communications on nuclear chemistry. The subjects covered include: Nuclear chemistry, Radiochemistry, Radiation chemistry, Radiobiological chemistry, Environmental radiochemistry, Production and control of radioisotopes and labelled compounds, Nuclear power plant chemistry, Nuclear fuel chemistry, Radioanalytical chemistry, Radiation detection and measurement, Nuclear instrumentation and automation, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信