{"title":"Osteoporosis screening using QCT-based cutoff value of Hounsfield units in patients with degenerative lumbar diseases","authors":"Da Zou, Xuan He, Zesen Shang, Dan Jin, Weishi Li","doi":"10.1007/s00586-024-08491-4","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Purpose</h3><p>In patients with degenerative lumbar diseases, we aimed to establish the cutoff value of Hounsfield units (HU) for osteoporosis screening on the basis of the relationship between computed tomography (CT) HU value and volume bone mineral density (BMD) measured by quantitative computed tomography (QCT).</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>A total of 136 patients aged ≥ 50 years with degenerative lumbar diseases were retrospectively included. Their QCT-BMD of L1-2 were recorded, and the CT values of L1-2 were measured with the same CT images of QCT. The degree of bone loss was evaluated with the criteria based on QCT-BMD: cutoff value of 80 mg/cm<sup>3</sup> for osteoporosis and cutoff value of 120 mg/cm<sup>3</sup> for osteopenia. The cutoff of CT value was acquired according to the linear regression equation between CT value and QCT-BMD.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>The rate of osteoporosis, osteopenia, normal BMD was 33.8% (46/136), 51.5% (70/136), and 14.7% (20/136), respectively. The Pearson correlation coefficients between CT value and QCT-BMD were over 0.9 (<i>P</i> < 0.05). The cutoff of average CT value of L1-2 was calculated and adjusted to 110HU for osteoporosis and 160HU for osteopenia according the equation: average QCT-BMD of L1-2 = 0.76 ✕ average CT value of L1-2–0.46 (<i>R</i><sup>2</sup> = 0.931, <i>P</i> < 0.001). Cutoff value of 110HU was 91.2% (42/46) sensitive and 88.9% (80/90) specific for identifying osteoporosis. The cutoff value of 160HU was 95.0% (19/20) sensitive and 96.6% (112/116) specific for distinguishing normal BMD from abnormal BMD (osteoporosis and osteopenia).</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>The CT value is effective in osteoporosis screening, and the QCT-based cutoff value is 110 HU for osteoporosis and 160 HU for osteopenia in the patients with degenerative lumbar disease.</p>","PeriodicalId":12323,"journal":{"name":"European Spine Journal","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Spine Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00586-024-08491-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
In patients with degenerative lumbar diseases, we aimed to establish the cutoff value of Hounsfield units (HU) for osteoporosis screening on the basis of the relationship between computed tomography (CT) HU value and volume bone mineral density (BMD) measured by quantitative computed tomography (QCT).
Methods
A total of 136 patients aged ≥ 50 years with degenerative lumbar diseases were retrospectively included. Their QCT-BMD of L1-2 were recorded, and the CT values of L1-2 were measured with the same CT images of QCT. The degree of bone loss was evaluated with the criteria based on QCT-BMD: cutoff value of 80 mg/cm3 for osteoporosis and cutoff value of 120 mg/cm3 for osteopenia. The cutoff of CT value was acquired according to the linear regression equation between CT value and QCT-BMD.
Results
The rate of osteoporosis, osteopenia, normal BMD was 33.8% (46/136), 51.5% (70/136), and 14.7% (20/136), respectively. The Pearson correlation coefficients between CT value and QCT-BMD were over 0.9 (P < 0.05). The cutoff of average CT value of L1-2 was calculated and adjusted to 110HU for osteoporosis and 160HU for osteopenia according the equation: average QCT-BMD of L1-2 = 0.76 ✕ average CT value of L1-2–0.46 (R2 = 0.931, P < 0.001). Cutoff value of 110HU was 91.2% (42/46) sensitive and 88.9% (80/90) specific for identifying osteoporosis. The cutoff value of 160HU was 95.0% (19/20) sensitive and 96.6% (112/116) specific for distinguishing normal BMD from abnormal BMD (osteoporosis and osteopenia).
Conclusion
The CT value is effective in osteoporosis screening, and the QCT-based cutoff value is 110 HU for osteoporosis and 160 HU for osteopenia in the patients with degenerative lumbar disease.
期刊介绍:
"European Spine Journal" is a publication founded in response to the increasing trend toward specialization in spinal surgery and spinal pathology in general. The Journal is devoted to all spine related disciplines, including functional and surgical anatomy of the spine, biomechanics and pathophysiology, diagnostic procedures, and neurology, surgery and outcomes. The aim of "European Spine Journal" is to support the further development of highly innovative spine treatments including but not restricted to surgery and to provide an integrated and balanced view of diagnostic, research and treatment procedures as well as outcomes that will enhance effective collaboration among specialists worldwide. The “European Spine Journal” also participates in education by means of videos, interactive meetings and the endorsement of educative efforts.
Official publication of EUROSPINE, The Spine Society of Europe