{"title":"Secondary removal of intramedullary metal debris from a defective Reamer-Irrigator-Aspirator (RIA) reamer head: A case report","authors":"Philipp Vetter,&nbsp;Christian Hübner,&nbsp;Sandro-Michael Heining,&nbsp;Christian Hierholzer,&nbsp;Hans-Christoph Pape","doi":"10.1016/j.tcr.2024.101112","DOIUrl":null,"url":null,"abstract":"<div><p>The Reamer-Irrigator-Aspirator (RIA) device represents a safe and efficient method to harvest autologous bone for grafting. However, hardware failure may occur, for example by breakage of the reamer head with metal debris remaining in the intramedullary canal.</p><p>This case report describes the uncomplicated secondary removal of femoral intramedullary metal debris from a broken RIA reamer head; three weeks after the final surgery of a two-stage Masquelet procedure for the treatment of posttraumatic segmental bone loss at the tibia.</p></div>","PeriodicalId":23291,"journal":{"name":"Trauma Case Reports","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352644024001353/pdfft?md5=0748436553d07af343e34237bbd4f590&pid=1-s2.0-S2352644024001353-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trauma Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352644024001353","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

The Reamer-Irrigator-Aspirator (RIA) device represents a safe and efficient method to harvest autologous bone for grafting. However, hardware failure may occur, for example by breakage of the reamer head with metal debris remaining in the intramedullary canal.

This case report describes the uncomplicated secondary removal of femoral intramedullary metal debris from a broken RIA reamer head; three weeks after the final surgery of a two-stage Masquelet procedure for the treatment of posttraumatic segmental bone loss at the tibia.

髓内金属碎片从有缺陷的铰刀-灌注器-喷气器(RIA)铰刀头上的二次清除:病例报告
铰刀-灌注器-呼吸器(RIA)装置是一种安全有效的获取自体骨进行移植的方法。本病例报告描述了在治疗外伤后胫骨节段性骨缺失的两阶段马斯奎莱手术的最后一次手术后三周,从断裂的 RIA 绞刀头上二次清除股骨髓内金属碎片的过程,过程并不复杂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Trauma Case Reports
Trauma Case Reports Medicine-Emergency Medicine
CiteScore
0.60
自引率
0.00%
发文量
131
审稿时长
26 weeks
期刊介绍: Trauma Case Reports is the only open access, online journal dedicated to the publication of case reports in all aspects of trauma care and accident surgery. Case reports on all aspects of trauma management, surgical procedures for all tissues, resuscitation, anaesthesia and trauma and tissue healing will be considered for publication by the international editorial team and will be subject to peer review. Bringing together these cases from an international authorship will shed light on surgical problems and help in their effective resolution.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信