Investigation of the effect of Al2O3/water nanofluid on the performance of a thermoelectric cooler to harvest water from humid air

IF 3.5 4区 环境科学与生态学 Q3 ENGINEERING, ENVIRONMENTAL
Emad Nazari, Mohammad Hassan Vakili and Mahdi Reiszadeh
{"title":"Investigation of the effect of Al2O3/water nanofluid on the performance of a thermoelectric cooler to harvest water from humid air","authors":"Emad Nazari, Mohammad Hassan Vakili and Mahdi Reiszadeh","doi":"10.1039/D4EW00367E","DOIUrl":null,"url":null,"abstract":"<p >One of the sources of fresh water, especially in desert and water-scarce areas is atmospheric air. Cooling the moist air and lowering its temperature to the dew point leads to the condensation of present water. This research used a thermoelectric cooler system to obtain water from humid air. Al<small><sub>2</sub></small>O<small><sub>3</sub></small>/water nanofluid was used to take the heat from the hot side of the thermoelectric cooler. Using a lab setting, the convective heat transfer coefficient of various nanofluid concentrations was determined. According to the findings, for high Reynolds numbers, the heat transfer coefficient of the nanofluid is between 5000 and 7000 W m<small><sup>−2</sup></small> K<small><sup>−1</sup></small>. The effect of some parameters, such as velocity and humidity of the inlet air as well as the nanofluid concentration, on the amount of harvested water was studied experimentally and numerically. The results showed that increasing air humidity led to an increase in the amount of water obtained and the system's performance coefficient. The maximum amount of extracted water at a relative humidity of 20% and air temperature of 35 °C was obtained at 51.3 ml h<small><sup>−1</sup></small> at the inlet air velocity of 1.4 m s<small><sup>−1</sup></small> and using a nanofluid of 5 wt%. The velocity of inlet air had a significant effect on the performance coefficient of the system. Increasing the velocity from 1.1 to 1.6 m s<small><sup>−1</sup></small> increased the COP by about 30%. In general, the research results showed that thermoelectric coolers could be used as portable devices to extract fresh water from the air, even with low humidity.</p>","PeriodicalId":75,"journal":{"name":"Environmental Science: Water Research & Technology","volume":" 11","pages":" 3035-3044"},"PeriodicalIF":3.5000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Science: Water Research & Technology","FirstCategoryId":"93","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ew/d4ew00367e","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

One of the sources of fresh water, especially in desert and water-scarce areas is atmospheric air. Cooling the moist air and lowering its temperature to the dew point leads to the condensation of present water. This research used a thermoelectric cooler system to obtain water from humid air. Al2O3/water nanofluid was used to take the heat from the hot side of the thermoelectric cooler. Using a lab setting, the convective heat transfer coefficient of various nanofluid concentrations was determined. According to the findings, for high Reynolds numbers, the heat transfer coefficient of the nanofluid is between 5000 and 7000 W m−2 K−1. The effect of some parameters, such as velocity and humidity of the inlet air as well as the nanofluid concentration, on the amount of harvested water was studied experimentally and numerically. The results showed that increasing air humidity led to an increase in the amount of water obtained and the system's performance coefficient. The maximum amount of extracted water at a relative humidity of 20% and air temperature of 35 °C was obtained at 51.3 ml h−1 at the inlet air velocity of 1.4 m s−1 and using a nanofluid of 5 wt%. The velocity of inlet air had a significant effect on the performance coefficient of the system. Increasing the velocity from 1.1 to 1.6 m s−1 increased the COP by about 30%. In general, the research results showed that thermoelectric coolers could be used as portable devices to extract fresh water from the air, even with low humidity.

Abstract Image

研究 Al2O3/水纳米流体对从潮湿空气中获取水的热电冷却器性能的影响
淡水的来源之一是大气中的空气,尤其是在沙漠和缺水地区。冷却潮湿的空气,将其温度降至露点,就会凝结出水。这项研究利用热电冷却器系统从潮湿空气中获取水。Al2O3 / 水纳米流体用于从热电半导体制冷片的热侧获取热量。通过实验室环境,测定了不同浓度纳米流体的对流传热系数。根据研究结果,在高雷诺数情况下,纳米流体的传热系数在 5000 至 7000 w/m2.K 之间。实验和数值研究了一些参数,如入口空气的速度和湿度以及非流体浓度对采水量的影响。结果表明,增加空气湿度可提高取水量和系统的性能系数。在相对湿度为 20%、气温为 35 oC 的条件下,当进气速度为 1.4 m/s、使用 5% 重量的纳米流体时,最大采水量为 51.3 ml/h。进气速度对系统的性能系数有显著影响。将速度从 1.1 m/s 提高到 1.6 m/s,可使 COP 提高约 30%。总之,研究结果表明,热电冷却器可用作从空气中提取淡水的便携式设备,即使在湿度较低的情况下也是如此。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Environmental Science: Water Research & Technology
Environmental Science: Water Research & Technology ENGINEERING, ENVIRONMENTALENVIRONMENTAL SC-ENVIRONMENTAL SCIENCES
CiteScore
8.60
自引率
4.00%
发文量
206
期刊介绍: Environmental Science: Water Research & Technology seeks to showcase high quality research about fundamental science, innovative technologies, and management practices that promote sustainable water.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信