Graeme Prentice-Mott, Lorna Maru, Alexandra Kossik, Evelyn Makena Mugambi, Cynthia Ombok, Raymond Odinoh, Florence Mwikali, Ruthie Rosenberg, Isaac Ngere, Jennifer Murphy, David Berendes
{"title":"ATP-based assessments of recent cleaning and disinfection for high-touch surfaces in low-resource shared toilets","authors":"Graeme Prentice-Mott, Lorna Maru, Alexandra Kossik, Evelyn Makena Mugambi, Cynthia Ombok, Raymond Odinoh, Florence Mwikali, Ruthie Rosenberg, Isaac Ngere, Jennifer Murphy, David Berendes","doi":"10.1038/s41545-024-00380-z","DOIUrl":null,"url":null,"abstract":"Quality improvements and reduction of disease risk for low-resource shared sanitation facilities require cleanliness assessment approaches that are both rigorous and practical. Using Adenosine Triphosphate (ATP) bioluminescence testing, we assessed contamination on high-touch (HT) surfaces (inner door handles) at 32 shared toilet sites in Kisumu, Kenya. In public toilets, contamination was lowest after cleaning and disinfection (C&D) with 0.5% chlorine solution (adjusted difference in mean log10 Relative Light Units per 100 cm2 (aDiff): −1.61; CI: −2.43, −0.59), followed by C&D with 0.1% chlorine solution (aDiff: −1.16; CI: −1.77, −0.55). ATP levels were not associated with overall observable toilet cleanliness and had poor agreement with visually assessed HT surface cleanliness. Our findings demonstrate the utility of this field-feasible method for detecting the impact of recent C&D in low-resource shared toilets, a novel setting for ATP cleanliness testing, while also highlighting the importance of using effective C&D procedures and addressing HT surfaces within cleaning protocols.","PeriodicalId":19375,"journal":{"name":"npj Clean Water","volume":null,"pages":null},"PeriodicalIF":10.4000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.nature.com/articles/s41545-024-00380-z.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"npj Clean Water","FirstCategoryId":"5","ListUrlMain":"https://www.nature.com/articles/s41545-024-00380-z","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Quality improvements and reduction of disease risk for low-resource shared sanitation facilities require cleanliness assessment approaches that are both rigorous and practical. Using Adenosine Triphosphate (ATP) bioluminescence testing, we assessed contamination on high-touch (HT) surfaces (inner door handles) at 32 shared toilet sites in Kisumu, Kenya. In public toilets, contamination was lowest after cleaning and disinfection (C&D) with 0.5% chlorine solution (adjusted difference in mean log10 Relative Light Units per 100 cm2 (aDiff): −1.61; CI: −2.43, −0.59), followed by C&D with 0.1% chlorine solution (aDiff: −1.16; CI: −1.77, −0.55). ATP levels were not associated with overall observable toilet cleanliness and had poor agreement with visually assessed HT surface cleanliness. Our findings demonstrate the utility of this field-feasible method for detecting the impact of recent C&D in low-resource shared toilets, a novel setting for ATP cleanliness testing, while also highlighting the importance of using effective C&D procedures and addressing HT surfaces within cleaning protocols.
npj Clean WaterEnvironmental Science-Water Science and Technology
CiteScore
15.30
自引率
2.60%
发文量
61
审稿时长
5 weeks
期刊介绍:
npj Clean Water publishes high-quality papers that report cutting-edge science, technology, applications, policies, and societal issues contributing to a more sustainable supply of clean water. The journal's publications may also support and accelerate the achievement of Sustainable Development Goal 6, which focuses on clean water and sanitation.