Mahdi Zavvar, Sina Zargaran, Hamed Baghdadi, Peyvand Poopak, Amir Hossein Poopak, Fariba Nabatchian, Yousef Fatahi, Gelareh Khosravipour, Behzad Poopak
{"title":"Dihydrorhodamine-123 flow cytometry method: time for substantial revision in technical procedure.","authors":"Mahdi Zavvar, Sina Zargaran, Hamed Baghdadi, Peyvand Poopak, Amir Hossein Poopak, Fariba Nabatchian, Yousef Fatahi, Gelareh Khosravipour, Behzad Poopak","doi":"10.1093/labmed/lmae076","DOIUrl":null,"url":null,"abstract":"<p><p>The dihydrorhodamine 123 assay is generally applied to measure the production of intracellular reactive oxygen species in neutrophils using flow cytometry and is considered a diagnostic evaluation for chronic granulomatous disease. In fact, there is a broad range of variables that can directly or indirectly affect test results, either individually or collectively. It is therefore crucial to identify the ideal requirements to achieve reliable results as well as using these requirements to provide standard operating procedures that should be taken into account. Therefore, we focus on aligning optimum results by comparing preanalytical and analytical phases that influence test results, such as the effect of various anticoagulants, transport and maintaining temperature (24°C or 4°C) of samples, test prime run time, appropriate solution concentrations, and effect of incubation temperature (24°C or 37°C) during the test run.</p>","PeriodicalId":94124,"journal":{"name":"Laboratory medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/labmed/lmae076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The dihydrorhodamine 123 assay is generally applied to measure the production of intracellular reactive oxygen species in neutrophils using flow cytometry and is considered a diagnostic evaluation for chronic granulomatous disease. In fact, there is a broad range of variables that can directly or indirectly affect test results, either individually or collectively. It is therefore crucial to identify the ideal requirements to achieve reliable results as well as using these requirements to provide standard operating procedures that should be taken into account. Therefore, we focus on aligning optimum results by comparing preanalytical and analytical phases that influence test results, such as the effect of various anticoagulants, transport and maintaining temperature (24°C or 4°C) of samples, test prime run time, appropriate solution concentrations, and effect of incubation temperature (24°C or 37°C) during the test run.