MPPD: A User-Friendly Posture Deformation Program for Mesh-Type Computational Phantoms.

IF 1 4区 医学 Q4 ENVIRONMENTAL SCIENCES
Haegin Han, Jaehyo Kim, Sungho Moon, Gahee Son, Bangho Shin, Hyeonil Kim, Suhyeon Kim, Chansoo Choi, Chan Hyeong Kim
{"title":"MPPD: A User-Friendly Posture Deformation Program for Mesh-Type Computational Phantoms.","authors":"Haegin Han, Jaehyo Kim, Sungho Moon, Gahee Son, Bangho Shin, Hyeonil Kim, Suhyeon Kim, Chansoo Choi, Chan Hyeong Kim","doi":"10.1097/HP.0000000000001884","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Recently, the International Commission on Radiological Protection (ICRP) released adult Mesh-type Reference Computational Phantoms (MRCPs), which have great advantage in high deformability. Previous studies have exploited their high deformability to investigate the dosimetric influence of varying statures and postures, demonstrating significant variations in radiation doses. However, the previous studies are constrained by their inability to consider both stature and posture concurrently and by the limited range of postures analyzed. In the present study, a computer program named MPPD (Mesh-type Phantom Posture Deformer) was developed, a user-friendly graphical user interface that enables users to adjust the posture of adult MRCPs and corresponding library phantoms. The MPPD program was applied to deform five adult male phantoms of different statures into sitting and kneeling postures, showcasing its rapid computational speed and minimal RAM usage. The effectiveness of the MPPD program for dose calculation was also investigated by computing the detriment-weighted doses for MPPD-deformed adult male MRCPs, which showed good agreement with dose values for existing posture-deformed phantoms of the previous study. Furthermore, as an application of the MPPD program, the combined dosimetric impact of stature and posture was investigated, which is the inaugural effort to estimate doses by considering these factors concurrently. The result showed that the impact of stature and posture on radiation doses could largely vary depending on the radiation source, highlighting the importance of simultaneous consideration of stature and posture for accurate dose estimation.</p>","PeriodicalId":12976,"journal":{"name":"Health physics","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HP.0000000000001884","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract: Recently, the International Commission on Radiological Protection (ICRP) released adult Mesh-type Reference Computational Phantoms (MRCPs), which have great advantage in high deformability. Previous studies have exploited their high deformability to investigate the dosimetric influence of varying statures and postures, demonstrating significant variations in radiation doses. However, the previous studies are constrained by their inability to consider both stature and posture concurrently and by the limited range of postures analyzed. In the present study, a computer program named MPPD (Mesh-type Phantom Posture Deformer) was developed, a user-friendly graphical user interface that enables users to adjust the posture of adult MRCPs and corresponding library phantoms. The MPPD program was applied to deform five adult male phantoms of different statures into sitting and kneeling postures, showcasing its rapid computational speed and minimal RAM usage. The effectiveness of the MPPD program for dose calculation was also investigated by computing the detriment-weighted doses for MPPD-deformed adult male MRCPs, which showed good agreement with dose values for existing posture-deformed phantoms of the previous study. Furthermore, as an application of the MPPD program, the combined dosimetric impact of stature and posture was investigated, which is the inaugural effort to estimate doses by considering these factors concurrently. The result showed that the impact of stature and posture on radiation doses could largely vary depending on the radiation source, highlighting the importance of simultaneous consideration of stature and posture for accurate dose estimation.

MPPD:用于网格型计算模型的用户友好型姿势变形程序。
摘要:最近,国际辐射防护委员会(ICRP)发布了成人网格型参考计算模型(MRCPs),该模型具有高变形性的巨大优势。以往的研究利用其高变形性研究了不同身材和姿势对剂量学的影响,结果表明辐射剂量存在显著差异。然而,以往的研究由于无法同时考虑身材和姿势,以及分析的姿势范围有限而受到限制。在本研究中,开发了一个名为 MPPD(网格型模型姿势变形器)的计算机程序,它是一个用户友好型图形用户界面,使用户能够调整成人 MRCP 和相应库模型的姿势。应用 MPPD 程序将五个不同身材的成年男性模型变形为坐姿和跪姿,展示了其快速的计算速度和最小的内存使用量。通过计算 MPPD 变形成年男性 MRCP 的去甲加权剂量,研究人员还考察了 MPPD 程序在剂量计算方面的有效性,结果显示与之前研究中现有姿势变形模型的剂量值非常吻合。此外,作为 MPPD 程序的一项应用,还研究了身材和姿势对剂量学的综合影响,这是首次通过同时考虑这些因素来估算剂量。结果表明,身材和姿势对辐射剂量的影响会因辐射源的不同而有很大差异,这凸显了同时考虑身材和姿势对准确估算剂量的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Health physics
Health physics 医学-公共卫生、环境卫生与职业卫生
CiteScore
4.20
自引率
0.00%
发文量
324
审稿时长
3-8 weeks
期刊介绍: Health Physics, first published in 1958, provides the latest research to a wide variety of radiation safety professionals including health physicists, nuclear chemists, medical physicists, and radiation safety officers with interests in nuclear and radiation science. The Journal allows professionals in these and other disciplines in science and engineering to stay on the cutting edge of scientific and technological advances in the field of radiation safety. The Journal publishes original papers, technical notes, articles on advances in practical applications, editorials, and correspondence. Journal articles report on the latest findings in theoretical, practical, and applied disciplines of epidemiology and radiation effects, radiation biology and radiation science, radiation ecology, and related fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信