Evaluating the Solubility of Endodontic Sealers in Response to Static and Dynamic Stress: An In Vitro Study.

IF 1.6 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Mohammad Ali Saghiri, Mahsa Amanabi, Elham Samadi, Armen Asatourian, Fatereh Samadi, Steven M Morgano
{"title":"Evaluating the Solubility of Endodontic Sealers in Response to Static and Dynamic Stress: An In Vitro Study.","authors":"Mohammad Ali Saghiri, Mahsa Amanabi, Elham Samadi, Armen Asatourian, Fatereh Samadi, Steven M Morgano","doi":"10.14744/eej.2023.62207","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study investigated the effect of static and dynamic conditions on the solubility of three en-dodontic sealers: AH Plus (an epoxy-resin-based sealer), Bio-C Sealer (a bioceramic sealer), and EndoSequence BC (a bioceramic sealer).</p><p><strong>Methods: </strong>Plastic moulds were used to create 150 specimens, which were divided into three groups, with each group being filled with one of the three sealers. After the setting time, the specimens were removed from the moulds, dried, and weighed. Thirty specimens from each group were subdivided into three subgroups and stored in distilled water for 30, 60, or 90 days, while the remaining 20 specimens in each group were subdivid-ed into four subgroups and subjected to 0, 20, 50, or 100 thermocycling cycles. After storage time and thermo-cycling, the specimens were reweighed, and the weight loss and solubility percentage were calculated. The data were analysed using one-way ANOVA, Post Hoc Tukey, and Pearson correlation tests (p<0.05).</p><p><strong>Results: </strong>The results showed that AH Plus had the lowest solubility, followed by EndoSequence BC and then Bio-C Sealer (p<0.0001). Both static and dynamic conditions had a negative effect on the solubility of all tested sealers, with the effect being more pronounced in bioceramic sealers. The increase in storage days and the number of thermocycling cycles were significantly correlated with the increasing solubility levels of all tested sealers (p<0.0001).</p><p><strong>Conclusion: </strong>The increased solubility of endodontic sealers may have a negative impact on long-term treat-ment outcomes. Both static and dynamic conditions can affect the solubility of endodontic sealers.</p>","PeriodicalId":11860,"journal":{"name":"European Endodontic Journal","volume":"9 4","pages":"231-235"},"PeriodicalIF":1.6000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11413601/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14744/eej.2023.62207","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study investigated the effect of static and dynamic conditions on the solubility of three en-dodontic sealers: AH Plus (an epoxy-resin-based sealer), Bio-C Sealer (a bioceramic sealer), and EndoSequence BC (a bioceramic sealer).

Methods: Plastic moulds were used to create 150 specimens, which were divided into three groups, with each group being filled with one of the three sealers. After the setting time, the specimens were removed from the moulds, dried, and weighed. Thirty specimens from each group were subdivided into three subgroups and stored in distilled water for 30, 60, or 90 days, while the remaining 20 specimens in each group were subdivid-ed into four subgroups and subjected to 0, 20, 50, or 100 thermocycling cycles. After storage time and thermo-cycling, the specimens were reweighed, and the weight loss and solubility percentage were calculated. The data were analysed using one-way ANOVA, Post Hoc Tukey, and Pearson correlation tests (p<0.05).

Results: The results showed that AH Plus had the lowest solubility, followed by EndoSequence BC and then Bio-C Sealer (p<0.0001). Both static and dynamic conditions had a negative effect on the solubility of all tested sealers, with the effect being more pronounced in bioceramic sealers. The increase in storage days and the number of thermocycling cycles were significantly correlated with the increasing solubility levels of all tested sealers (p<0.0001).

Conclusion: The increased solubility of endodontic sealers may have a negative impact on long-term treat-ment outcomes. Both static and dynamic conditions can affect the solubility of endodontic sealers.

评估牙髓密封剂在静态和动态压力下的可溶性:体外研究
研究目的本研究调查了静态和动态条件对三种牙体牙髓封闭剂溶解度的影响:AH Plus(一种环氧树脂封闭剂)、Bio-C 封闭剂(一种生物陶瓷封闭剂)和 EndoSequence BC(一种生物陶瓷封闭剂):方法:使用塑料模具制作 150 个试样,分成三组,每组填充三种封闭剂中的一种。放置一段时间后,将试样从模具中取出,晾干并称重。每组中的 30 个试样被分成三个子组,分别在蒸馏水中储存 30、60 或 90 天,每组中的其余 20 个试样被分成四个子组,分别进行 0、20、50 或 100 次热循环。贮藏时间和热循环结束后,重新称重试样,计算重量损失和溶解度百分比。数据分析采用单因素方差分析、Post Hoc Tukey 和 Pearson 相关性检验(pResults):结果表明,AH Plus的溶解度最低,其次是EndoSequence BC,然后是Bio-C封闭剂(p结论:牙髓封闭剂溶解度的增加可能会对长期治疗效果产生负面影响。静态和动态条件都会影响牙髓封闭剂的溶解度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Endodontic Journal
European Endodontic Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.40
自引率
5.60%
发文量
25
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信