Highly sensitive voltammetric determination of hydrochlorothiazide using a glassy carbon electrode modified with Super P carbon black nanoparticles†

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Domingos R. Santos-Neto, Carlos E. C. Lopes, Gabrielly P. Silva, Lizandra N. Castro, João Pedro C. Silva, Dianderson C. M. Ferreira, Luiz Ricardo G. Silva, Luiza M. F. Dantas and Iranaldo S. da Silva
{"title":"Highly sensitive voltammetric determination of hydrochlorothiazide using a glassy carbon electrode modified with Super P carbon black nanoparticles†","authors":"Domingos R. Santos-Neto, Carlos E. C. Lopes, Gabrielly P. Silva, Lizandra N. Castro, João Pedro C. Silva, Dianderson C. M. Ferreira, Luiz Ricardo G. Silva, Luiza M. F. Dantas and Iranaldo S. da Silva","doi":"10.1039/D4AY00900B","DOIUrl":null,"url":null,"abstract":"<p >Hydrochlorothiazide is an extremely important diuretic that regulates body functions, which can prevent several diseases. However, the abuse of this diuretic is concerning since it does not require a medical prescription, particularly for aesthetic purposes such as weight loss, which can lead to various health problems, including ventricular arrhythmia. The present work aims to use a glassy carbon electrode modified with Super P carbon black (SPCB/GCE) to quantify hydrochlorothiazide through Linear Sweep Adsorptive Stripping Voltammetry (LSAdSV). The modification of the GCE with SPCB significantly improved the response of hydrochlorothiazide. Furthermore, due to the adsorptive nature of charge transport, applying preconcentration time enhanced sensitivity. The optimized system provided a linear range of 0.5 to 30.0 μmol L<small><sup>−1</sup></small> with a detection limit of 0.083 μmol L<small><sup>−1</sup></small>. Pharmaceutical tablet analyses indicated approximately 25 mg per tablet, which was confirmed by the UV-vis and in agreement with that indicated by the manufacturer. Furthermore, analyses of the tea, synthetic urine, tap water and lake water samples indicated recovery values close to 100%, demonstrating that there was no matrix effect. Therefore, it is possible to infer that the proposed method together with the sensor modified with carbon black nanoparticles presented excellent results, demonstrating that it can be an alternative method of monitoring this drug in different samples.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay00900b","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Hydrochlorothiazide is an extremely important diuretic that regulates body functions, which can prevent several diseases. However, the abuse of this diuretic is concerning since it does not require a medical prescription, particularly for aesthetic purposes such as weight loss, which can lead to various health problems, including ventricular arrhythmia. The present work aims to use a glassy carbon electrode modified with Super P carbon black (SPCB/GCE) to quantify hydrochlorothiazide through Linear Sweep Adsorptive Stripping Voltammetry (LSAdSV). The modification of the GCE with SPCB significantly improved the response of hydrochlorothiazide. Furthermore, due to the adsorptive nature of charge transport, applying preconcentration time enhanced sensitivity. The optimized system provided a linear range of 0.5 to 30.0 μmol L−1 with a detection limit of 0.083 μmol L−1. Pharmaceutical tablet analyses indicated approximately 25 mg per tablet, which was confirmed by the UV-vis and in agreement with that indicated by the manufacturer. Furthermore, analyses of the tea, synthetic urine, tap water and lake water samples indicated recovery values close to 100%, demonstrating that there was no matrix effect. Therefore, it is possible to infer that the proposed method together with the sensor modified with carbon black nanoparticles presented excellent results, demonstrating that it can be an alternative method of monitoring this drug in different samples.

Abstract Image

使用超 P 纳米炭黑修饰的玻璃碳电极高灵敏伏安法测定氢氯噻嗪。
氢氯噻嗪是一种极其重要的利尿剂,可以调节身体机能,预防多种疾病。然而,这种利尿剂的滥用令人担忧,因为它不需要医生处方,尤其是出于减肥等美容目的,这可能导致各种健康问题,包括室性心律失常。本研究旨在使用超 P 炭黑修饰的玻璃碳电极(SPCB/GCE),通过线性扫描吸附剥离伏安法(LSAdSV)对氢氯噻嗪进行定量。用 SPCB 修饰 GCE 后,氢氯噻嗪的反应明显改善。此外,由于电荷传输的吸附性,预浓缩时间的应用提高了灵敏度。优化系统的线性范围为 0.5 至 30.0 μmol L-1,检测限为 0.083 μmol L-1。药片分析表明,每片药片含有约 25 毫克,紫外可见光谱证实了这一点,并与制造商提供的数据一致。此外,对茶叶、合成尿液、自来水和湖水样品的分析表明,回收率接近 100%,表明不存在基质效应。因此,可以推断出所建议的方法以及用碳黑纳米颗粒修饰的传感器都取得了很好的结果,证明它可以作为监测不同样品中该药物的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信