Alicia Broussard , Bill Venier , Abeer Salhia Rafati , Angeline Beltsos , Joseph Lee , Jessica Bailey , Denny Sakkas , Michael G. Collins
{"title":"Effort in manual operation of reproductive health cryostorage facilities","authors":"Alicia Broussard , Bill Venier , Abeer Salhia Rafati , Angeline Beltsos , Joseph Lee , Jessica Bailey , Denny Sakkas , Michael G. Collins","doi":"10.1016/j.rbmo.2024.104348","DOIUrl":null,"url":null,"abstract":"<div><h3>Research question</h3><p>What areas of manual IVF cryostorage operations are common to the safe operation of IVF cryostorage facilities and require effort from embryologists?</p></div><div><h3>Design</h3><p>Observational time and motion data were collected by two observers equipped with the digital cameras over 2 weeks at four well-characterized US IVF centres (sites α, β, γ and δ) from 12 participants performing cryostorage tasks. To understand the work processes of the different sites and assist in the data analysis, informal interviews were conducted with the study participants and laboratory directors. Data were analysed to identify work processes that might be eliminated or diminished by automation and software improvements.</p></div><div><h3>Results</h3><p>On average, it took 3.4 data record queries per retrieval from cryostorage to identify a cane, while the canister was lifted an average of 1.5 times per retrieval, with a mean 11.8 ± 9.2 s per lift. Of the total time spent working with cryostorage equipment, 47.25% was of a fatiguing nature. Sites α, β and γ utilized one person to fill the liquid nitrogen storage Dewars, while site δ had two technicians working in tandem to move and fill the Dewars, with different frequencies and determination factors for refills and efficiencies.</p></div><div><h3>Conclusions</h3><p>This time and motion study demonstrated significant time investment, task redundancy and fatiguing working conditions among embryologists using manual cryostorage processes. There was a disparity of processes and space capacity across different laboratories. Some of these issues may be addressed by the integration of automation and technology solutions.</p></div>","PeriodicalId":21134,"journal":{"name":"Reproductive biomedicine online","volume":null,"pages":null},"PeriodicalIF":3.7000,"publicationDate":"2024-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1472648324005376/pdfft?md5=42e95bffc126b0109ab7cca1a06dbc58&pid=1-s2.0-S1472648324005376-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reproductive biomedicine online","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1472648324005376","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Research question
What areas of manual IVF cryostorage operations are common to the safe operation of IVF cryostorage facilities and require effort from embryologists?
Design
Observational time and motion data were collected by two observers equipped with the digital cameras over 2 weeks at four well-characterized US IVF centres (sites α, β, γ and δ) from 12 participants performing cryostorage tasks. To understand the work processes of the different sites and assist in the data analysis, informal interviews were conducted with the study participants and laboratory directors. Data were analysed to identify work processes that might be eliminated or diminished by automation and software improvements.
Results
On average, it took 3.4 data record queries per retrieval from cryostorage to identify a cane, while the canister was lifted an average of 1.5 times per retrieval, with a mean 11.8 ± 9.2 s per lift. Of the total time spent working with cryostorage equipment, 47.25% was of a fatiguing nature. Sites α, β and γ utilized one person to fill the liquid nitrogen storage Dewars, while site δ had two technicians working in tandem to move and fill the Dewars, with different frequencies and determination factors for refills and efficiencies.
Conclusions
This time and motion study demonstrated significant time investment, task redundancy and fatiguing working conditions among embryologists using manual cryostorage processes. There was a disparity of processes and space capacity across different laboratories. Some of these issues may be addressed by the integration of automation and technology solutions.
期刊介绍:
Reproductive BioMedicine Online covers the formation, growth and differentiation of the human embryo. It is intended to bring to public attention new research on biological and clinical research on human reproduction and the human embryo including relevant studies on animals. It is published by a group of scientists and clinicians working in these fields of study. Its audience comprises researchers, clinicians, practitioners, academics and patients.
Context:
The period of human embryonic growth covered is between the formation of the primordial germ cells in the fetus until mid-pregnancy. High quality research on lower animals is included if it helps to clarify the human situation. Studies progressing to birth and later are published if they have a direct bearing on events in the earlier stages of pregnancy.