Generation of input spectrum for electrolysis stack degradation test applied to wind power PEM hydrogen production

IF 1.9 Q4 ENERGY & FUELS
Yanhui Xu , Guanlin Li , Yuyuan Gui , Zhengmao Li
{"title":"Generation of input spectrum for electrolysis stack degradation test applied to wind power PEM hydrogen production","authors":"Yanhui Xu ,&nbsp;Guanlin Li ,&nbsp;Yuyuan Gui ,&nbsp;Zhengmao Li","doi":"10.1016/j.gloei.2024.08.006","DOIUrl":null,"url":null,"abstract":"<div><p>Hydrogen production by proton exchange membrane electrolysis has good fluctuation adaptability, making it suitable for hydrogen production by electrolysis in fluctuating power sources such as wind power. However, current research on the durability of proton exchange membrane electrolyzers is insufficient. Studying the typical operating conditions of wind power electrolysis for hydrogen production can provide boundary conditions for performance and degradation tests of electrolysis stacks. In this study, the operating condition spectrum of an electrolysis stack degradation test cycle was proposed. Based on the rate of change of the wind farm output power and the time-averaged peak-valley difference, a fluctuation output power sample set was formed. The characteristic quantities that played an important role in the degradation of the electrolysis stack were selected. Dimensionality reduction of the operating data was performed using principal component analysis. Clustering analysis of the data segments was completed using an improved Gaussian mixture clustering algorithm. Taking the annual output power data of wind farms in Northwest China with a sampling rate of 1 min as an example, the cyclic operating condition spectrum of the proton-exchange membrane electrolysis stack degradation test was constructed. After preliminary simulation analysis, the typical operating condition proposed in this paper effectively reflects the impact of the original curve on the performance degradation of the electrolysis stack. This study provides a method for evaluating the degradation characteristics and system efficiency of an electrolysis stack due to fluctuations in renewable energy.</p></div>","PeriodicalId":36174,"journal":{"name":"Global Energy Interconnection","volume":"7 4","pages":"Pages 462-474"},"PeriodicalIF":1.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2096511724000665/pdf?md5=51b59c89b74af8f5169221718325b4db&pid=1-s2.0-S2096511724000665-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Energy Interconnection","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2096511724000665","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

Hydrogen production by proton exchange membrane electrolysis has good fluctuation adaptability, making it suitable for hydrogen production by electrolysis in fluctuating power sources such as wind power. However, current research on the durability of proton exchange membrane electrolyzers is insufficient. Studying the typical operating conditions of wind power electrolysis for hydrogen production can provide boundary conditions for performance and degradation tests of electrolysis stacks. In this study, the operating condition spectrum of an electrolysis stack degradation test cycle was proposed. Based on the rate of change of the wind farm output power and the time-averaged peak-valley difference, a fluctuation output power sample set was formed. The characteristic quantities that played an important role in the degradation of the electrolysis stack were selected. Dimensionality reduction of the operating data was performed using principal component analysis. Clustering analysis of the data segments was completed using an improved Gaussian mixture clustering algorithm. Taking the annual output power data of wind farms in Northwest China with a sampling rate of 1 min as an example, the cyclic operating condition spectrum of the proton-exchange membrane electrolysis stack degradation test was constructed. After preliminary simulation analysis, the typical operating condition proposed in this paper effectively reflects the impact of the original curve on the performance degradation of the electrolysis stack. This study provides a method for evaluating the degradation characteristics and system efficiency of an electrolysis stack due to fluctuations in renewable energy.

生成适用于风电 PEM 制氢的电解堆降解测试输入频谱
质子交换膜电解法制氢具有良好的波动适应性,适用于风力发电等波动电源的电解制氢。然而,目前对质子交换膜电解槽耐久性的研究还不够。研究风电电解制氢的典型运行条件可以为电解堆的性能和降解测试提供边界条件。本研究提出了电解堆降解试验周期的运行条件谱。根据风电场输出功率的变化率和时间平均峰谷差,形成了波动输出功率样本集。选取了对电解槽退化起重要作用的特征量。使用主成分分析法对运行数据进行降维处理。使用改进的高斯混合聚类算法完成了数据段的聚类分析。以中国西北地区采样率为 1 分钟的风电场年输出功率数据为例,构建了质子交换膜电解堆降解试验的周期运行状况谱。经过初步仿真分析,本文提出的典型运行工况能有效反映原始曲线对电解堆性能衰减的影响。本研究为评估可再生能源波动引起的电解堆退化特性和系统效率提供了一种方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Global Energy Interconnection
Global Energy Interconnection Engineering-Automotive Engineering
CiteScore
5.70
自引率
0.00%
发文量
985
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信