An electrochemical biosensor equipped with a logic circuit as a smart automaton for two-miRNA pattern detection†

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Analyst Pub Date : 2024-08-26 DOI:10.1039/D4AN00719K
Benting Xie, Shimao Du, Hejun Gao, Juan Zhang, Hongquan Fu and Yunwen Liao
{"title":"An electrochemical biosensor equipped with a logic circuit as a smart automaton for two-miRNA pattern detection†","authors":"Benting Xie, Shimao Du, Hejun Gao, Juan Zhang, Hongquan Fu and Yunwen Liao","doi":"10.1039/D4AN00719K","DOIUrl":null,"url":null,"abstract":"<p >Detecting multiple targets in complex cellular and biological environments yields more reliable results than single-label assays. Here, we introduced an electrochemical biosensor equipped with computing functions, acting as a smart automaton to enable computing-based detection. By defining the logic combinations of miR-21 and miR-122 as detection patterns, we proposed the corresponding AND and OR detection automata. In both logic gate modes, miR-21 and miR-122 could be replaced with single-stranded F<small><sub>O</sub></small> or F<small><sub>A</sub></small>, modified with Fc, binding to the S chain on the electrode surface. This process led to a significant decrease in the square wave voltammetry (SWV) of Fc on the same sensing platform, as numerous ferrocene (Fc)-tagged DNA fragments escaped from the electrode surface. Experimental results indicated that both automata efficiently and sensitively detected the presence of the two targets. This strategy highlighted how a small amount of target could generate a large current signal decrease in the logic automata, significantly reducing the detection limit for monitoring low-abundance targets. Moreover, the short-stranded DNA components of the detection automata exhibited a simple composition and easy programmability of probe sequences, offering an innovative detection mode. This simplified the complex process of detection, data collection, computation, and evaluation. The direct detection result (“0” or “1”) was exported according to the embedded computation code. This approach could be expanded into a detection system for identifying other sets of biomarkers, enhancing its potential for clinical applications.</p>","PeriodicalId":63,"journal":{"name":"Analyst","volume":" 20","pages":" 5110-5117"},"PeriodicalIF":3.6000,"publicationDate":"2024-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/an/d4an00719k","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Detecting multiple targets in complex cellular and biological environments yields more reliable results than single-label assays. Here, we introduced an electrochemical biosensor equipped with computing functions, acting as a smart automaton to enable computing-based detection. By defining the logic combinations of miR-21 and miR-122 as detection patterns, we proposed the corresponding AND and OR detection automata. In both logic gate modes, miR-21 and miR-122 could be replaced with single-stranded FO or FA, modified with Fc, binding to the S chain on the electrode surface. This process led to a significant decrease in the square wave voltammetry (SWV) of Fc on the same sensing platform, as numerous ferrocene (Fc)-tagged DNA fragments escaped from the electrode surface. Experimental results indicated that both automata efficiently and sensitively detected the presence of the two targets. This strategy highlighted how a small amount of target could generate a large current signal decrease in the logic automata, significantly reducing the detection limit for monitoring low-abundance targets. Moreover, the short-stranded DNA components of the detection automata exhibited a simple composition and easy programmability of probe sequences, offering an innovative detection mode. This simplified the complex process of detection, data collection, computation, and evaluation. The direct detection result (“0” or “1”) was exported according to the embedded computation code. This approach could be expanded into a detection system for identifying other sets of biomarkers, enhancing its potential for clinical applications.

Abstract Image

配备逻辑电路的电化学生物传感器是用于检测两种 miRNA 模式的智能自动机
在复杂的细胞和生物环境中检测多个目标比单标记检测能获得更可靠的结果。在这里,我们介绍了一种配备计算功能的电化学生物传感器,它就像智能自动机一样实现了基于计算的检测。通过定义 miR-21 和 miR-122 的逻辑组合作为检测模式,我们提出了相应的 AND 和 OR 检测自动机。在这两种逻辑门模式中,miR-21 和 miR-122 都可以用单链 FO 或 FA 代替,并用 Fc 修饰,与电极表面的 S 链结合。这一过程导致 Fc 在同一传感平台上的方波伏安法(SWV)显著下降,因为大量二茂铁(Fc)标记的 DNA 片段从电极表面逃逸。实验结果表明,这两种自动装置都能高效、灵敏地判断两个目标的存在。这一策略凸显了少量目标物如何在逻辑自动机中产生较大的电流信号下降,从而大大降低了监测低丰度目标物的检测限。此外,检测自动装置的短链 DNA 组件成分简单,探针序列易于编程,提供了一种创新的检测模式。这简化了复杂的检测、数据收集、计算和评估过程。直接检测结果("0 "或 "1")根据嵌入的计算代码输出。这种方法可扩展为识别其他生物标记物的检测系统,从而提高其临床应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: The home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信