Surgical outcomes and intraoperative parameters of 3D visualization system versus conventional microscopes for macular surgery in highly myopic eyes, a prospective randomized clinical trial.

IF 2.3 2区 医学 Q2 OPHTHALMOLOGY
Mei-Chi Tsui, Yi-Ting Hsieh, Tso-Ting Lai, Cheng-Yung Lee, Yun Hsia, Shih-Wen Wang, I-Hsin Ma, Kuo-Chi Hung, Chang-Pin Lin, Chang-Hao Yang, Chung-May Yang, Tzyy-Chang Ho
{"title":"Surgical outcomes and intraoperative parameters of 3D visualization system versus conventional microscopes for macular surgery in highly myopic eyes, a prospective randomized clinical trial.","authors":"Mei-Chi Tsui, Yi-Ting Hsieh, Tso-Ting Lai, Cheng-Yung Lee, Yun Hsia, Shih-Wen Wang, I-Hsin Ma, Kuo-Chi Hung, Chang-Pin Lin, Chang-Hao Yang, Chung-May Yang, Tzyy-Chang Ho","doi":"10.1097/IAE.0000000000004207","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the surgical outcomes and intraoperative parameters of 3D visualization system for macular diseases in highly myopic eyes.</p><p><strong>Methods: </strong>In this single-center, prospective, randomized, comparative interventional study, 40 highly myopic eyes (axial length > 26mm) were randomly assigned to either a 3D visualization system or a conventional microscope (CM) group. Surgical outcomes and intraoperative parameters, including the number of indocyanine green (ICG) injections, surgical time, and epiretinal membrane (ERM)/ internal limiting membrane (ILM) peeling time, were compared.</p><p><strong>Results: </strong>The 3D group required significantly fewer ICG injections (1.3 ± 0.5 vs. 2.3 ± 0.7, p < 0.001), had shorter ERM/ILM peeling times (522.8 ± 258.0 vs. 751.8 ± 320.2 sec, p < 0.05), and experienced fewer intraoperative retinal hemorrhages (0 vs. 7 cases, p < 0.05) compared to the CM group. Anatomical and functional outcomes were comparable between the two groups.</p><p><strong>Conclusion: </strong>The 3D system exhibited a lower number of ICG injections, shorter ERM/ILM peeling times and a reduced incidence of intraoperative retinal hemorrhages, suggesting the 3D visualization system may offer advantages for macular surgery in highly myopic eyes.</p>","PeriodicalId":54486,"journal":{"name":"Retina-The Journal of Retinal and Vitreous Diseases","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Retina-The Journal of Retinal and Vitreous Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IAE.0000000000004207","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the surgical outcomes and intraoperative parameters of 3D visualization system for macular diseases in highly myopic eyes.

Methods: In this single-center, prospective, randomized, comparative interventional study, 40 highly myopic eyes (axial length > 26mm) were randomly assigned to either a 3D visualization system or a conventional microscope (CM) group. Surgical outcomes and intraoperative parameters, including the number of indocyanine green (ICG) injections, surgical time, and epiretinal membrane (ERM)/ internal limiting membrane (ILM) peeling time, were compared.

Results: The 3D group required significantly fewer ICG injections (1.3 ± 0.5 vs. 2.3 ± 0.7, p < 0.001), had shorter ERM/ILM peeling times (522.8 ± 258.0 vs. 751.8 ± 320.2 sec, p < 0.05), and experienced fewer intraoperative retinal hemorrhages (0 vs. 7 cases, p < 0.05) compared to the CM group. Anatomical and functional outcomes were comparable between the two groups.

Conclusion: The 3D system exhibited a lower number of ICG injections, shorter ERM/ILM peeling times and a reduced incidence of intraoperative retinal hemorrhages, suggesting the 3D visualization system may offer advantages for macular surgery in highly myopic eyes.

高度近视眼黄斑手术中三维可视化系统与传统显微镜的手术效果和术中参数的前瞻性随机临床试验。
目的:研究三维可视系统治疗高度近视眼黄斑疾病的手术效果和术中参数:在这项单中心、前瞻性、随机、比较性干预研究中,40 只高度近视眼(轴向长度大于 26 毫米)被随机分配到 3D 可视化系统组或传统显微镜组。比较了手术结果和术中参数,包括吲哚青绿(ICG)注射次数、手术时间和视网膜外膜(ERM)/内缘膜(ILM)剥离时间:结果:与CM组相比,3D组所需ICG注射次数明显较少(1.3 ± 0.5对2.3 ± 0.7,p <0.001),ERM/ILM剥离时间较短(522.8 ± 258.0对751.8 ± 320.2秒,p <0.05),术中视网膜出血较少(0对7例,p <0.05)。两组的解剖和功能结果相当:结论:三维系统的ICG注射次数更少,ERM/ILM剥离时间更短,术中视网膜出血的发生率更低,这表明三维可视系统在高度近视眼的黄斑手术中可能具有优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.70
自引率
9.10%
发文量
554
审稿时长
3-6 weeks
期刊介绍: ​RETINA® focuses exclusively on the growing specialty of vitreoretinal disorders. The Journal provides current information on diagnostic and therapeutic techniques. Its highly specialized and informative, peer-reviewed articles are easily applicable to clinical practice. In addition to regular reports from clinical and basic science investigators, RETINA® publishes special features including periodic review articles on pertinent topics, special articles dealing with surgical and other therapeutic techniques, and abstract cards. Issues are abundantly illustrated in vivid full color. Published 12 times per year, RETINA® is truly a “must have” publication for anyone connected to this field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信