[Clinical application of perforator-based propeller flaps in repair of hand wound].

Q3 Medicine
Hui Wang, Haifeng Wang, Haoyu Qin, Ruizheng Hao, Tiepeng Ma, Ying Liu, Bin Wang
{"title":"[Clinical application of perforator-based propeller flaps in repair of hand wound].","authors":"Hui Wang, Haifeng Wang, Haoyu Qin, Ruizheng Hao, Tiepeng Ma, Ying Liu, Bin Wang","doi":"10.7507/1002-1892.202404006","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the effectiveness of the perforator-based propeller flaps (PPFs) based on digital artery (DA) and dorsal metacarpal artery (DMA) in repairing hand wounds.</p><p><strong>Methods: </strong>The clinical data of 45 patients with hand wounds between January 2018 and March 2023 were retrospectively analyzed. There were 27 males and 18 females with an average age of 41.2 years (range, 14-72 years). The causes of injury included twist injury in 15 cases, crush injury in 19 cases, and cut injury in 11 cases. The injured parts included 32 cases of digits, 10 cases of dorsal hand, and 3 cases of palmar hand, all of which had tendon, joint, and bone exposure. The time from injury to operation ranged from 2 to 8 hours (mean, 4.3 hours). The wound sizes after debridement ranged from 1.8 cm×1.0 cm to 5.0 cm×3.5 cm. Twenty-eight cases were repaired by the PPFs based on DA and 17 cases were repaired by the PPFs based on DMA. The flap size ranged from 2.5 cm×1.1 cm to 8.5 cm×4.0 cm. The defects of the donor sites in 14 patients were closed directly and the defects in the left 31 patients were resurfaced with free full-thickness skin graft from the proximal medial forearm.</p><p><strong>Results: </strong>All the flaps survived after operation. Two cases of the PPF based on DA and 1 case of the PPF based on DMA underwent partially blisters at the distal end and healed after dressing change. The incisions in the donor site healed by first intention and the skin grafts survived. All patients were followed up 10-33 months, with a mean of 15.4 months. At last follow-up, the static two-point discrimination of the PPFs based on DA and DMA were 4-14 mm and 8-20 mm with the averages of 8.1 mm and 13.3 mm, respectively. According to the Michigan Hand Outcomes Questionnaire, 20 patients were very satisfied with the appearance of the PPF based on DA and 8 patients were satisfied; 8 patients were very satisfied with the appearance of the PPF based on DMA and 9 patients were satisfied. Based on the Vancouver Scar Scale (VSS), the appearance scores of the donor site of the PPFs based on DA and DMA were 2-7 and 4-9, with the averages of 4.2 and 6.1, respectively.</p><p><strong>Conclusion: </strong>The two kinds of PPFs are reliable in blood supply and easy to harvest, which provide a good method for emergency repair of small and medium area wounds in the hand.</p>","PeriodicalId":23979,"journal":{"name":"中国修复重建外科杂志","volume":"38 8","pages":"1016-1021"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11335591/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国修复重建外科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7507/1002-1892.202404006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate the effectiveness of the perforator-based propeller flaps (PPFs) based on digital artery (DA) and dorsal metacarpal artery (DMA) in repairing hand wounds.

Methods: The clinical data of 45 patients with hand wounds between January 2018 and March 2023 were retrospectively analyzed. There were 27 males and 18 females with an average age of 41.2 years (range, 14-72 years). The causes of injury included twist injury in 15 cases, crush injury in 19 cases, and cut injury in 11 cases. The injured parts included 32 cases of digits, 10 cases of dorsal hand, and 3 cases of palmar hand, all of which had tendon, joint, and bone exposure. The time from injury to operation ranged from 2 to 8 hours (mean, 4.3 hours). The wound sizes after debridement ranged from 1.8 cm×1.0 cm to 5.0 cm×3.5 cm. Twenty-eight cases were repaired by the PPFs based on DA and 17 cases were repaired by the PPFs based on DMA. The flap size ranged from 2.5 cm×1.1 cm to 8.5 cm×4.0 cm. The defects of the donor sites in 14 patients were closed directly and the defects in the left 31 patients were resurfaced with free full-thickness skin graft from the proximal medial forearm.

Results: All the flaps survived after operation. Two cases of the PPF based on DA and 1 case of the PPF based on DMA underwent partially blisters at the distal end and healed after dressing change. The incisions in the donor site healed by first intention and the skin grafts survived. All patients were followed up 10-33 months, with a mean of 15.4 months. At last follow-up, the static two-point discrimination of the PPFs based on DA and DMA were 4-14 mm and 8-20 mm with the averages of 8.1 mm and 13.3 mm, respectively. According to the Michigan Hand Outcomes Questionnaire, 20 patients were very satisfied with the appearance of the PPF based on DA and 8 patients were satisfied; 8 patients were very satisfied with the appearance of the PPF based on DMA and 9 patients were satisfied. Based on the Vancouver Scar Scale (VSS), the appearance scores of the donor site of the PPFs based on DA and DMA were 2-7 and 4-9, with the averages of 4.2 and 6.1, respectively.

Conclusion: The two kinds of PPFs are reliable in blood supply and easy to harvest, which provide a good method for emergency repair of small and medium area wounds in the hand.

[基于穿孔器的螺旋桨皮瓣在修复手部伤口中的临床应用]。
目的研究基于数字动脉(DA)和掌背动脉(DMA)的穿孔螺旋桨皮瓣(PPF)修复手部伤口的效果:回顾性分析2018年1月至2023年3月期间45例手部创伤患者的临床资料。其中男性 27 人,女性 18 人,平均年龄 41.2 岁(14-72 岁)。受伤原因包括扭伤15例,挤压伤19例,切割伤11例。受伤部位包括指骨 32 例、手背 10 例、手掌 3 例,均有肌腱、关节和骨骼外露。从受伤到手术时间为 2 至 8 小时(平均 4.3 小时)。清创后的伤口大小从 1.8 厘米×1.0 厘米到 5.0 厘米×3.5 厘米不等。其中 28 例采用基于 DA 的 PPF 进行修复,17 例采用基于 DMA 的 PPF 进行修复。皮瓣大小从 2.5 厘米×1.1 厘米到 8.5 厘米×4.0 厘米不等。14 例患者供皮部位的缺损直接缝合,其余 31 例患者的缺损用前臂内侧近端游离全厚皮片再植:结果:所有皮瓣术后均存活。2例基于DA的PPF和1例基于DMA的PPF远端出现部分水泡,换药后愈合。供皮部位的切口以第一意向愈合,植皮存活。所有患者均接受了 10-33 个月的随访,平均随访时间为 15.4 个月。在最后一次随访中,基于DA和DMA的PPF静态两点分辨力分别为4-14毫米和8-20毫米,平均值分别为8.1毫米和13.3毫米。根据密歇根手部结果问卷调查,20 名患者对基于 DA 的 PPF 外观非常满意,8 名患者满意;8 名患者对基于 DMA 的 PPF 外观非常满意,9 名患者满意。根据温哥华瘢痕量表(VSS),基于 DA 和 DMA 的 PPF 的供区外观评分分别为 2-7 分和 4-9 分,平均值分别为 4.2 分和 6.1 分:两种 PPFs 供血可靠,易于采集,为手部中小面积伤口的紧急修复提供了一种良好的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
中国修复重建外科杂志
中国修复重建外科杂志 Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
11334
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信