Excellence in the management of Advanced Hybrid Closed-Loop Systems: Lessons from the Polish cohort

IF 6.1 3区 医学 Q1 ENDOCRINOLOGY & METABOLISM
Bartłomiej Matejko , Tim van den Heuvel , Javier Castaneda , Arcelia Arrieta , Katarzyna Cyranka , Ohad Cohen , Maciej Małecki , Tomasz Klupa
{"title":"Excellence in the management of Advanced Hybrid Closed-Loop Systems: Lessons from the Polish cohort","authors":"Bartłomiej Matejko ,&nbsp;Tim van den Heuvel ,&nbsp;Javier Castaneda ,&nbsp;Arcelia Arrieta ,&nbsp;Katarzyna Cyranka ,&nbsp;Ohad Cohen ,&nbsp;Maciej Małecki ,&nbsp;Tomasz Klupa","doi":"10.1016/j.diabres.2024.111832","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The aim of the study was to analyze the real-world performance of MiniMed 780G (MM780G) Advanced Hybrid Closed Loop (AHCL) system users from Poland (PL) and compare it to the European region excluding Poland (EU-PL) in order to identify factors contributing to potential differences. The former achieved some of the best Time in Range (TIR) results globally using this technology.</p></div><div><h3>Methods</h3><p>CareLink Personal data uploaded by MM780G system users from August 2020 to December 2022 were analyzed<strong>.</strong></p></div><div><h3>Results</h3><p>The Polish users (N=1304) on average reached to TIR of 79.1 ± 8.7 % (vs 73.0 ± 10.0 % for EU-PL, N=55659), a TBR&lt;54 mg/dL of 0.6 ± 0.7 % (vs 0.4 ± 0.6 %) and a TBR&lt;70 mg/dL of 2.9 ± 2.1 % (vs 2.1 ± 1.8 %). The adoption rate of optimal settings (i.e, GT=100 mg/dL, AIT=2hr) in PL was high (19.7 % vs 6.3 %), and filtering on optimal setting users led to less pronounced differences in glycemic control between PL and EU-PL. A univariable analysis with post-AHCL TIR showed that geography itself (PL vs EU-PL) is not a significant contributor to a high post-AHCL TIR (p = 0.15), and that much of the Polish post-AHCL TIR can be explained by the high pre-AHCL TIR.</p></div><div><h3>Conclusion</h3><p>The Polish MM780G users achieved better glycemic control than the general European population (excluding Poland). This is largely attributable to the adoption of optimal settings in Poland and the already high glycemic outcomes at system start. As these characteristics can be implemented elsewhere, we believe this outstanding result can be obtained in other countries as well.</p></div>","PeriodicalId":11249,"journal":{"name":"Diabetes research and clinical practice","volume":"216 ","pages":"Article 111832"},"PeriodicalIF":6.1000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0168822724007423/pdfft?md5=68c1ce921e597f02849f34399c99e5b6&pid=1-s2.0-S0168822724007423-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes research and clinical practice","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168822724007423","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Background

The aim of the study was to analyze the real-world performance of MiniMed 780G (MM780G) Advanced Hybrid Closed Loop (AHCL) system users from Poland (PL) and compare it to the European region excluding Poland (EU-PL) in order to identify factors contributing to potential differences. The former achieved some of the best Time in Range (TIR) results globally using this technology.

Methods

CareLink Personal data uploaded by MM780G system users from August 2020 to December 2022 were analyzed.

Results

The Polish users (N=1304) on average reached to TIR of 79.1 ± 8.7 % (vs 73.0 ± 10.0 % for EU-PL, N=55659), a TBR<54 mg/dL of 0.6 ± 0.7 % (vs 0.4 ± 0.6 %) and a TBR<70 mg/dL of 2.9 ± 2.1 % (vs 2.1 ± 1.8 %). The adoption rate of optimal settings (i.e, GT=100 mg/dL, AIT=2hr) in PL was high (19.7 % vs 6.3 %), and filtering on optimal setting users led to less pronounced differences in glycemic control between PL and EU-PL. A univariable analysis with post-AHCL TIR showed that geography itself (PL vs EU-PL) is not a significant contributor to a high post-AHCL TIR (p = 0.15), and that much of the Polish post-AHCL TIR can be explained by the high pre-AHCL TIR.

Conclusion

The Polish MM780G users achieved better glycemic control than the general European population (excluding Poland). This is largely attributable to the adoption of optimal settings in Poland and the already high glycemic outcomes at system start. As these characteristics can be implemented elsewhere, we believe this outstanding result can be obtained in other countries as well.

先进混合闭环系统的卓越管理:波兰的经验教训。
研究背景本研究旨在分析波兰(PL)MiniMed 780G(MM780G)高级混合闭环(AHCL)系统用户的实际表现,并与除波兰以外的欧洲地区(EU-PL)进行比较,以找出造成潜在差异的因素。前者使用该技术在全球范围内取得了最佳范围内时间(TIR)结果:方法:分析 MM780G 系统用户在 2020 年 8 月至 2022 年 12 月期间上传的 CareLink 个人数据:结果:波兰用户(N=1304)的平均 TIR 为 79.1 ± 8.7 %(欧盟-波兰为 73.0 ± 10.0 %,N=55659),TBRC 结论:波兰 MM780G 用户的平均 TIR 为 79.1 ± 8.7 %(欧盟-波兰为 73.0 ± 10.0 %,N=55659):波兰 MM780G 用户的血糖控制情况优于欧洲一般人群(不包括波兰)。这在很大程度上归功于波兰采用了最佳设置,以及在系统启动时已经取得了较高的血糖结果。由于这些特点可以在其他地方实施,我们相信其他国家也能取得这一优异成绩。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diabetes research and clinical practice
Diabetes research and clinical practice 医学-内分泌学与代谢
CiteScore
10.30
自引率
3.90%
发文量
862
审稿时长
32 days
期刊介绍: Diabetes Research and Clinical Practice is an international journal for health-care providers and clinically oriented researchers that publishes high-quality original research articles and expert reviews in diabetes and related areas. The role of the journal is to provide a venue for dissemination of knowledge and discussion of topics related to diabetes clinical research and patient care. Topics of focus include translational science, genetics, immunology, nutrition, psychosocial research, epidemiology, prevention, socio-economic research, complications, new treatments, technologies and therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信