Feasibility, reproducibility, and accuracy of echocardiographic right ventricular systolic function assessments in childhood cancer survivors at risk for heart failure

IF 1.6 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Heidi Ostler MD, Lin Liu PhD, Khang Tong MS, Maria T. Acuero MAS, Juliana Gomez-Arostegui MD, MPH, Seth Degner RDCS, Sun Choo MD, Fraser Golding MD, Sanjeet Hegde MD, PhD, Dennis J. Kuo MD, MS, Hari K. Narayan MD, MSCE
{"title":"Feasibility, reproducibility, and accuracy of echocardiographic right ventricular systolic function assessments in childhood cancer survivors at risk for heart failure","authors":"Heidi Ostler MD,&nbsp;Lin Liu PhD,&nbsp;Khang Tong MS,&nbsp;Maria T. Acuero MAS,&nbsp;Juliana Gomez-Arostegui MD, MPH,&nbsp;Seth Degner RDCS,&nbsp;Sun Choo MD,&nbsp;Fraser Golding MD,&nbsp;Sanjeet Hegde MD, PhD,&nbsp;Dennis J. Kuo MD, MS,&nbsp;Hari K. Narayan MD, MSCE","doi":"10.1111/echo.15905","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>We sought to assess the feasibility, reproducibility, and accuracy of conventional and newer echocardiographic measures of right ventricular (RV) systolic function in adolescent and young adult childhood cancer survivors treated with anthracyclines.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Echocardiography and cardiac magnetic resonance imaging (CMR) were acquired ≤60 days apart in prospectively recruited survivors and RV functional measures were quantitated by blinded observers. Repeat quantitation was performed in a subset to evaluate reproducibility. For each echocardiographic measure, Spearman correlations with CMR measures were calculated, and values in participants with CMR RV ejection fraction (RVEF) ≥48% and RVEF &lt;48% were compared using two sample Wilcoxon rank-sum tests.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Among 58 participants, mean age was 18.2 years (range 13.1–25.2) and five participants had CMR RVEF &lt;48%. Intra- and inter-observer coefficients of variation were 8.2%–10.1% and 10.5%–12.0% for adjusted automated strain measures, and 5.2%–8.7% and 2.7% for 3D RVEF, respectively. No echocardiographic measures were significantly correlated with CMR RVEF; only tricuspid annular plane systolic excursion was correlated with CMR RV stroke volume (<i>r</i> = .392, <i>p</i> = .003). Participants with RV dysfunction had worse automated global longitudinal strain (−20.3% vs. −23.9%, <i>p</i> = .007) and free wall longitudinal strain (−23.7% vs. −26.7%, <i>p</i> = .09).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Echocardiographic strain and 3D RV function measurements were feasible and reproducible in at-risk childhood cancer survivors. Although not associated with CMR RVEF in this population with predominantly normal RV function, automated strain measurements were more abnormal in participants with RV dysfunction, suggesting potential clinical utility of these measures.</p>\n </section>\n </div>","PeriodicalId":50558,"journal":{"name":"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques","volume":"41 8","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2024-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/echo.15905","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Echocardiography-A Journal of Cardiovascular Ultrasound and Allied Techniques","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/echo.15905","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

We sought to assess the feasibility, reproducibility, and accuracy of conventional and newer echocardiographic measures of right ventricular (RV) systolic function in adolescent and young adult childhood cancer survivors treated with anthracyclines.

Methods

Echocardiography and cardiac magnetic resonance imaging (CMR) were acquired ≤60 days apart in prospectively recruited survivors and RV functional measures were quantitated by blinded observers. Repeat quantitation was performed in a subset to evaluate reproducibility. For each echocardiographic measure, Spearman correlations with CMR measures were calculated, and values in participants with CMR RV ejection fraction (RVEF) ≥48% and RVEF <48% were compared using two sample Wilcoxon rank-sum tests.

Results

Among 58 participants, mean age was 18.2 years (range 13.1–25.2) and five participants had CMR RVEF <48%. Intra- and inter-observer coefficients of variation were 8.2%–10.1% and 10.5%–12.0% for adjusted automated strain measures, and 5.2%–8.7% and 2.7% for 3D RVEF, respectively. No echocardiographic measures were significantly correlated with CMR RVEF; only tricuspid annular plane systolic excursion was correlated with CMR RV stroke volume (r = .392, p = .003). Participants with RV dysfunction had worse automated global longitudinal strain (−20.3% vs. −23.9%, p = .007) and free wall longitudinal strain (−23.7% vs. −26.7%, p = .09).

Conclusions

Echocardiographic strain and 3D RV function measurements were feasible and reproducible in at-risk childhood cancer survivors. Although not associated with CMR RVEF in this population with predominantly normal RV function, automated strain measurements were more abnormal in participants with RV dysfunction, suggesting potential clinical utility of these measures.

Abstract Image

对有心力衰竭风险的儿童癌症幸存者进行右心室收缩功能超声心动图评估的可行性、再现性和准确性。
目的:我们试图评估使用蒽环类药物治疗的青少年和成年儿童癌症幸存者右心室收缩功能的传统和新型超声心动图测量方法的可行性、可重复性和准确性:方法:在前瞻性招募的幸存者中,超声心动图和心脏磁共振成像(CMR)的采集间隔时间不超过 60 天,并由盲人观察者对 RV 功能测量进行量化。为了评估重现性,对一个子集进行了重复量化。对于每项超声心动图测量,均计算了与 CMR 测量的 Spearman 相关性,以及 CMR RV 射血分数(RVEF)≥48% 和 RVEF 结果的参与者的数值:在 58 位参与者中,平均年龄为 18.2 岁(范围为 13.1-25.2),5 位参与者有 CMR RVEF 结论:超声心动图应变和三维 RV 功能测量在高危儿童癌症幸存者中是可行且可重复的。虽然在这一主要RV功能正常的人群中,自动应变测量与CMR RVEF无关,但在RV功能障碍的参与者中,自动应变测量的异常程度更高,这表明这些测量方法具有潜在的临床实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.40
自引率
6.70%
发文量
211
审稿时长
3-6 weeks
期刊介绍: Echocardiography: A Journal of Cardiovascular Ultrasound and Allied Techniques is the official publication of the International Society of Cardiovascular Ultrasound. Widely recognized for its comprehensive peer-reviewed articles, case studies, original research, and reviews by international authors. Echocardiography keeps its readership of echocardiographers, ultrasound specialists, and cardiologists well informed of the latest developments in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信