Cardiac intravoxel incoherent motion diffusion-weighted imaging to assess myocardial microcirculation dysfunction in hypertension.

IF 2.9 2区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Quantitative Imaging in Medicine and Surgery Pub Date : 2024-08-01 Epub Date: 2024-07-11 DOI:10.21037/qims-24-108
Lei Zhao, Haipeng Wang, Duwang Qiu, Liwen Tian, Teng Wang, Yucheng Yang, Yongle Sun, Weibo Chen, Cuiyan Wang
{"title":"Cardiac intravoxel incoherent motion diffusion-weighted imaging to assess myocardial microcirculation dysfunction in hypertension.","authors":"Lei Zhao, Haipeng Wang, Duwang Qiu, Liwen Tian, Teng Wang, Yucheng Yang, Yongle Sun, Weibo Chen, Cuiyan Wang","doi":"10.21037/qims-24-108","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Myocardial microcirculation dysfunction is the most potent predictor of adverse cardiovascular events in hypertension. The current study aimed to apply intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) to assess hypertension-related microcirculation dysfunction.</p><p><strong>Methods: </strong>In this prospective study, 102 participants were recruited from our hospital and underwent cardiac magnetic resonance (CMR) examination on a 3T scanning system. Hypertensive patients were divided into 3 subgroups based on blood pressure (BP) types. Two experienced CMR radiologists independently analyzed all images, and Bland-Altman analysis was applied to assess intra- and inter-observer reproducibility. Cardiac function indexes and IVIM-DWI parameters were compared between the hypertension and healthy control groups, as well as among the three hypertension subgroups.</p><p><strong>Results: </strong>Totally 62 participants with hypertension and 27 healthy controls were included. 13 participants were excluded for poor quality of IVIM-DWI images. Significantly higher maximal left ventricular wall thickness (10.3±2.0 <i>vs.</i> 8.6±1.4 mm, P<0.001) and left ventricular mass index (49.0±9.1 <i>vs.</i> 42.1±7.5 g/m<sup>2</sup>, P<0.05) were observed inhypertension group compared with healthy control group. There were significant statistical differences in pseudo diffusion (D*) between them (81.3±16.3 <i>vs.</i> 111.8±18.9 mm<sup>2</sup>/s, P<0.001), as well as among the three hypertension subgroups (99.4±13.9 <i>vs.</i> 79.7±10.6 <i>vs.</i> 67.1±6.6 mm<sup>2</sup>/s, P<0.001). Participants with poor quality of IVIM-DWI images had higher heart rates (72.2±10.0 <i>vs.</i> 62.0±8.1 bpm, P<0.001).</p><p><strong>Conclusions: </strong>IVIM-DWI is feasible for quantitatively evaluating myocardial microcirculation dysfunction in hypertension. The D* parameter has a potential value for assessing the severity of microcirculation dysfunction in different BP categories.</p>","PeriodicalId":54267,"journal":{"name":"Quantitative Imaging in Medicine and Surgery","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11320536/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quantitative Imaging in Medicine and Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/qims-24-108","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Myocardial microcirculation dysfunction is the most potent predictor of adverse cardiovascular events in hypertension. The current study aimed to apply intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) to assess hypertension-related microcirculation dysfunction.

Methods: In this prospective study, 102 participants were recruited from our hospital and underwent cardiac magnetic resonance (CMR) examination on a 3T scanning system. Hypertensive patients were divided into 3 subgroups based on blood pressure (BP) types. Two experienced CMR radiologists independently analyzed all images, and Bland-Altman analysis was applied to assess intra- and inter-observer reproducibility. Cardiac function indexes and IVIM-DWI parameters were compared between the hypertension and healthy control groups, as well as among the three hypertension subgroups.

Results: Totally 62 participants with hypertension and 27 healthy controls were included. 13 participants were excluded for poor quality of IVIM-DWI images. Significantly higher maximal left ventricular wall thickness (10.3±2.0 vs. 8.6±1.4 mm, P<0.001) and left ventricular mass index (49.0±9.1 vs. 42.1±7.5 g/m2, P<0.05) were observed inhypertension group compared with healthy control group. There were significant statistical differences in pseudo diffusion (D*) between them (81.3±16.3 vs. 111.8±18.9 mm2/s, P<0.001), as well as among the three hypertension subgroups (99.4±13.9 vs. 79.7±10.6 vs. 67.1±6.6 mm2/s, P<0.001). Participants with poor quality of IVIM-DWI images had higher heart rates (72.2±10.0 vs. 62.0±8.1 bpm, P<0.001).

Conclusions: IVIM-DWI is feasible for quantitatively evaluating myocardial microcirculation dysfunction in hypertension. The D* parameter has a potential value for assessing the severity of microcirculation dysfunction in different BP categories.

评估高血压心肌微循环功能障碍的心脏体细胞内非相干运动弥散加权成像。
背景:心肌微循环功能障碍是高血压心血管不良事件最有力的预测因素。本研究旨在应用体细胞内非相干运动弥散加权成像(IVIM-DWI)评估高血压相关的微循环功能障碍:在这项前瞻性研究中,本院招募了 102 名参与者,他们在 3T 扫描系统上接受了心脏磁共振(CMR)检查。根据血压(BP)类型将高血压患者分为 3 个亚组。两名经验丰富的 CMR 放射科医师独立分析所有图像,并采用 Bland-Altman 分析法评估观察者内部和观察者之间的可重复性。比较了高血压组和健康对照组以及三个高血压亚组的心功能指数和 IVIM-DWI 参数:结果:共纳入 62 名高血压患者和 27 名健康对照组患者。结果:共纳入 62 名高血压患者和 27 名健康对照组患者,其中 13 人因 IVIM-DWI 图像质量不佳而被排除在外。最大左心室壁厚度(10.3±2.0 vs. 8.6±1.4 mm,Pvs.42.1±7.5 g/m2,Pvs.111.8±18.9 mm2/s,Pvs.79.7±10.6 vs. 67.1±6.6 mm2/s,Pvs.62.0±8.1 bpm,PConclusions)显著增加:IVIM-DWI 可用于定量评估高血压患者的心肌微循环功能障碍。D* 参数在评估不同血压类别的微循环功能障碍严重程度方面具有潜在价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Quantitative Imaging in Medicine and Surgery
Quantitative Imaging in Medicine and Surgery Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
4.20
自引率
17.90%
发文量
252
期刊介绍: Information not localized
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信