{"title":"Ambient lighting alters pattern electroretinogram P50 peak time and spatial sensitivity.","authors":"Lisa Tucker, Oliver R Marmoy, Siân E Handley, Dorothy A Thompson","doi":"10.1007/s10633-024-09984-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Our aim was to explore the effect of ambient lighting on the pattern ERG (PERG).</p><p><strong>Methods: </strong>We compared PERGs recorded in two conditions; room lights on and room lights off. PERGs from 21 adult participants were recorded from each eye to high contrast checks of 50' side width, reversing 3rps in a large (30°) and then standard (15°) field. This was performed first in lights-ON conditions, then 2 min after the room lights were switched off. A minimum of 2 averages of 300 trials were acquired for each condition. A subset of 10 participants had PERGs recorded to a 50' check width with a range of stimulus contrasts (96-18%), also to a range of different check widths (100'-12') at high contrast in both ambient lighting conditions in a 30° field.</p><p><strong>Results: </strong>The lights-ON P50 median peak time (PT) was 3 ms earlier than the lights-OFF P50 from the 30° field (range 0-5 ms) and 15° field (range 0-6 ms). The earlier lights-ON P50 PT was evident at different stimulus contrasts, even after accounting for stimulus contrast reductions associated with stray ambient lighting in lights-ON conditions. Lights-OFF and lights-ON P50 PT were similar to different check widths; the lights-OFF P50 PT to a 50' check width matched the lights-ON P50 PT to a 25' check width.</p><p><strong>Conclusion: </strong>PERG P50 PT in lights-ON ambient light conditions can be earlier than in lights-OFF ambient light conditions. The difference in P50 PT with ambient light may reflect alterations in spatial sensitivity associated with retinal adaptation. These results emphasise the clinical importance of consistent ambient lighting for PERG recording and calibration.</p>","PeriodicalId":11207,"journal":{"name":"Documenta Ophthalmologica","volume":" ","pages":"77-86"},"PeriodicalIF":2.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11442543/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Documenta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10633-024-09984-9","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Our aim was to explore the effect of ambient lighting on the pattern ERG (PERG).

Methods: We compared PERGs recorded in two conditions; room lights on and room lights off. PERGs from 21 adult participants were recorded from each eye to high contrast checks of 50' side width, reversing 3rps in a large (30°) and then standard (15°) field. This was performed first in lights-ON conditions, then 2 min after the room lights were switched off. A minimum of 2 averages of 300 trials were acquired for each condition. A subset of 10 participants had PERGs recorded to a 50' check width with a range of stimulus contrasts (96-18%), also to a range of different check widths (100'-12') at high contrast in both ambient lighting conditions in a 30° field.

Results: The lights-ON P50 median peak time (PT) was 3 ms earlier than the lights-OFF P50 from the 30° field (range 0-5 ms) and 15° field (range 0-6 ms). The earlier lights-ON P50 PT was evident at different stimulus contrasts, even after accounting for stimulus contrast reductions associated with stray ambient lighting in lights-ON conditions. Lights-OFF and lights-ON P50 PT were similar to different check widths; the lights-OFF P50 PT to a 50' check width matched the lights-ON P50 PT to a 25' check width.

Conclusion: PERG P50 PT in lights-ON ambient light conditions can be earlier than in lights-OFF ambient light conditions. The difference in P50 PT with ambient light may reflect alterations in spatial sensitivity associated with retinal adaptation. These results emphasise the clinical importance of consistent ambient lighting for PERG recording and calibration.

Abstract Image

环境照明会改变模式视网膜电图 P50 峰值时间和空间敏感性。
目的:我们的目的是探索环境光线对模式 ERG(PERG)的影响:我们比较了在两种条件下记录的 PERG:开灯和关灯。对 21 名成年参与者的每只眼睛的 PERGs 进行了记录,以获得边宽为 50' 的高对比度检查,在大视场(30°)和标准视场(15°)中反转 3rps。首先在开灯条件下进行,然后在室内灯光关闭 2 分钟后进行。每种情况下至少进行 2 次,每次平均 300 次。对 10 名参与者中的一个子集进行了 PERGs 记录,记录了 50' 检查宽度下的一系列刺激对比度(96-18%),还记录了 30° 视场中两种环境照明条件下高对比度下的一系列不同检查宽度(100'-12'):在 30° 视场(范围 0-5 ms)和 15° 视场(范围 0-6 ms)中,开灯 P50 中位峰值时间(PT)比关灯 P50 早 3 ms。在不同的刺激对比度下,"开灯 "时的 P50 峰值时间都明显提前,即使考虑到 "开灯 "条件下与杂散环境照明相关的刺激对比度降低也是如此。关灯和开灯时的 P50 PT 在不同检查宽度下相似;关灯时 P50 PT 在 50' 检查宽度下与开灯时 P50 PT 在 25' 检查宽度下相似:结论:开灯环境光条件下的 PERG P50 PT 可能早于关灯环境光条件下的 PERG P50 PT。环境光条件下 P50 PT 的差异可能反映了与视网膜适应相关的空间敏感性的改变。这些结果强调了一致的环境光对 PERG 记录和校准的临床重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Documenta Ophthalmologica
Documenta Ophthalmologica 医学-眼科学
CiteScore
3.50
自引率
21.40%
发文量
46
审稿时长
>12 weeks
期刊介绍: Documenta Ophthalmologica is an official publication of the International Society for Clinical Electrophysiology of Vision. The purpose of the journal is to promote the understanding and application of clinical electrophysiology of vision. Documenta Ophthalmologica will publish reviews, research articles, technical notes, brief reports and case studies which inform the readers about basic and clinical sciences related to visual electrodiagnosis and means to improve diagnosis and clinical management of patients using visual electrophysiology. Studies may involve animals or humans. In either case appropriate care must be taken to follow the Declaration of Helsinki for human subject or appropriate humane standards of animal care (e.g., the ARVO standards on Animal Care and Use).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信