Development of a SnO2-based 44Ti/44Sc generator for medical applications

IF 3.8 2区 化学 Q1 BIOCHEMICAL RESEARCH METHODS
{"title":"Development of a SnO2-based 44Ti/44Sc generator for medical applications","authors":"","doi":"10.1016/j.chroma.2024.465245","DOIUrl":null,"url":null,"abstract":"<div><p>Towards application of <sup>44</sup>Sc for diagnostic nuclear medicine, a <sup>44</sup>Ti/<sup>44</sup>Sc generator based on an inorganic resin has been evaluated. Unlike other radionuclide generators used for medical applications, the long-term retention of the parent <sup>44</sup>Ti is vital due to its long half life. Herein, tin dioxide (SnO<sub>2</sub>), a robust inorganic-based resin, has been synthesized and used as the stationary phase for a <sup>44</sup>Ti/<sup>44</sup>Sc generator. The sorption behavior of <sup>44</sup>Ti/<sup>44</sup>Sc was tested on SnO<sub>2</sub> with varying acids, concentrations, and times. Preliminary batch study results showed &gt;88 % <sup>44</sup>Ti retention to the resin at lower acid concentrations (0.05 M HNO<sub>3</sub> and 0.05 M HCl). A pilot generator was evaluated for a year, demonstrating 85.3 ± 2.8 % <sup>44</sup>Sc elution yields and 0.71 ± 0.14 % <sup>44</sup>Ti breakthrough in 5 M HNO<sub>3</sub>. Based on capacity studies, a 7.4 MBq (200 µCi) upscaled generator system was constructed for further evaluation of the SnO<sub>2</sub> resin stability and the efficacy of the eluted <sup>44</sup>Sc for radiolabeling. <sup>44</sup>Sc could be regularly eluted from this generator in 5 M HNO<sub>3</sub> with an overall average radiochemical yield 84.7 ± 9.5 %. Post-elution processing of the <sup>44</sup>Sc with DGA-normal resin removed all <sup>44</sup>Ti present and allowed for high <sup>44</sup>Sc-DOTA labeling yields of 94.2 ± 0.5 %. Overall, SnO<sub>2</sub> has been shown to be a viable material for a <sup>44</sup>Ti/<sup>44</sup>Sc generator.</p></div>","PeriodicalId":347,"journal":{"name":"Journal of Chromatography A","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography A","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021967324006198","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Towards application of 44Sc for diagnostic nuclear medicine, a 44Ti/44Sc generator based on an inorganic resin has been evaluated. Unlike other radionuclide generators used for medical applications, the long-term retention of the parent 44Ti is vital due to its long half life. Herein, tin dioxide (SnO2), a robust inorganic-based resin, has been synthesized and used as the stationary phase for a 44Ti/44Sc generator. The sorption behavior of 44Ti/44Sc was tested on SnO2 with varying acids, concentrations, and times. Preliminary batch study results showed >88 % 44Ti retention to the resin at lower acid concentrations (0.05 M HNO3 and 0.05 M HCl). A pilot generator was evaluated for a year, demonstrating 85.3 ± 2.8 % 44Sc elution yields and 0.71 ± 0.14 % 44Ti breakthrough in 5 M HNO3. Based on capacity studies, a 7.4 MBq (200 µCi) upscaled generator system was constructed for further evaluation of the SnO2 resin stability and the efficacy of the eluted 44Sc for radiolabeling. 44Sc could be regularly eluted from this generator in 5 M HNO3 with an overall average radiochemical yield 84.7 ± 9.5 %. Post-elution processing of the 44Sc with DGA-normal resin removed all 44Ti present and allowed for high 44Sc-DOTA labeling yields of 94.2 ± 0.5 %. Overall, SnO2 has been shown to be a viable material for a 44Ti/44Sc generator.

开发基于二氧化锡的 44Ti/44Sc 医疗应用发生器。
为了将 44Sc 应用于核医学诊断,对一种基于无机树脂的 44Ti/44Sc 发生器进行了评估。与其他用于医疗应用的放射性核素发生器不同,由于母体 44Ti 的半衰期较长,因此长期保持母体 44Ti 至关重要。本文合成了二氧化锡(SnO2)这种坚固的无机基树脂,并将其用作 44Ti/44Sc 发生器的固定相。在二氧化锡上测试了不同酸、浓度和时间下 44Ti/44Sc 的吸附行为。初步批量研究结果表明,在较低的酸浓度(0.05 M HNO3 和 0.05 M HCl)下,44Ti 在树脂上的保留率大于 88%。对试验发生器进行了为期一年的评估,结果表明在 5 M HNO3 中 44Sc 洗脱率为 85.3 ± 2.8 %,44Ti 突破率为 0.71 ± 0.14 %。在能力研究的基础上,我们建造了一个 7.4 MBq(200 µCi)的放大发生器系统,以进一步评估二氧化锰树脂的稳定性和洗脱出的 44Sc 在放射性标记中的有效性。44Sc 可以在 5 M HNO3 中从该发生器中定期洗脱出来,总体平均放射化学收率为 84.7 ± 9.5%。用 DGA 正常树脂对 44Sc 进行洗脱后处理,可去除所有 44Ti,44Sc-DOTA 的标记率高达 94.2 ± 0.5%。总之,二氧化锡已被证明是一种可行的 44Ti/44Sc 发生器材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Chromatography A
Journal of Chromatography A 化学-分析化学
CiteScore
7.90
自引率
14.60%
发文量
742
审稿时长
45 days
期刊介绍: The Journal of Chromatography A provides a forum for the publication of original research and critical reviews on all aspects of fundamental and applied separation science. The scope of the journal includes chromatography and related techniques, electromigration techniques (e.g. electrophoresis, electrochromatography), hyphenated and other multi-dimensional techniques, sample preparation, and detection methods such as mass spectrometry. Contributions consist mainly of research papers dealing with the theory of separation methods, instrumental developments and analytical and preparative applications of general interest.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信