{"title":"Clinical impact of cryoballoon posterior wall isolation using the cross-over technique in persistent atrial fibrillation.","authors":"Fuminori Odagiri, Takashi Tokano, Tetsuro Miyazaki, Koji Hirabayashi, Kai Ishi, Hiroshi Abe, Sayaki Ishiwata, Midori Kakihara, Masaaki Maki, Hiroki Matsumoto, Ryosuke Shimai, Tadao Aikawa, Shintaro Takano, Yuki Kimura, Shunsuke Kuroda, Hiroyuki Isogai, Dai Ozaki, Tomoyuki Shiozawa, Yuki Yasuda, Kiyoshi Takasu, Kenichi Iijima, Kazuhisa Takamura, Tomomi Matsubara, Haruna Tabuchi, Hidemori Hayashi, Ken Yokoyama, Gaku Sekita, Masataka Sumiyoshi, Yuji Nakazato, Tohru Minamino","doi":"10.1111/pace.15058","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Successful left atrial posterior wall isolation (LAPWI) using only the cryoballoon (CB) is technically challenging for the treatment of atrial fibrillation (AF). This study aimed to evaluate the efficacy of the cross-over technique, wherein an overlapped ablation is performed by placing the CB from both directions in contact with the LAPW.</p><p><strong>Methods: </strong>This was a single-center, retrospective, observational study of 194 consecutive patients with persistent atrial fibrillation (PerAF) who underwent a first-time procedure of pulmonary vein isolation (PVI) + PWI (108 patients) or PVI-only (86 patients) using the CB. The cross-over technique was applied in all LAPWI.</p><p><strong>Results: </strong>For ablation of the LA roof and bottom, respectively, a mean of 8.6 ± 1.0 (right to left [R→L] 4.3 ± 1.1 and left to right [L→R] 4.3 ± 1.1) and 9.1 ± 1.2 (R→L 4.6 ± 1.6 and L→R 4.5 ± 1.2) CB applications were delivered. LAPW was successfully isolated solely using the CB in 99.1% of patients. Although the PVI + PWI group had significantly longer procedure time, no severe adverse events were observed in either group. During a median follow-up of 19 months, freedom from recurrence of all atrial tachyarrhythmias was achieved in 93.5% of the PVI + PWI group and 72.9% of the PVI-only group (p = .011).</p><p><strong>Conclusions: </strong>LAPWI performed solely with the CB using the cross-over technique is feasibly, safe, and was independently associated with a significantly higher freedom from recurrence of atrial tachyarrhythmias compared with PVI alone in patients with PerAF.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.15058","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background and aims: Successful left atrial posterior wall isolation (LAPWI) using only the cryoballoon (CB) is technically challenging for the treatment of atrial fibrillation (AF). This study aimed to evaluate the efficacy of the cross-over technique, wherein an overlapped ablation is performed by placing the CB from both directions in contact with the LAPW.
Methods: This was a single-center, retrospective, observational study of 194 consecutive patients with persistent atrial fibrillation (PerAF) who underwent a first-time procedure of pulmonary vein isolation (PVI) + PWI (108 patients) or PVI-only (86 patients) using the CB. The cross-over technique was applied in all LAPWI.
Results: For ablation of the LA roof and bottom, respectively, a mean of 8.6 ± 1.0 (right to left [R→L] 4.3 ± 1.1 and left to right [L→R] 4.3 ± 1.1) and 9.1 ± 1.2 (R→L 4.6 ± 1.6 and L→R 4.5 ± 1.2) CB applications were delivered. LAPW was successfully isolated solely using the CB in 99.1% of patients. Although the PVI + PWI group had significantly longer procedure time, no severe adverse events were observed in either group. During a median follow-up of 19 months, freedom from recurrence of all atrial tachyarrhythmias was achieved in 93.5% of the PVI + PWI group and 72.9% of the PVI-only group (p = .011).
Conclusions: LAPWI performed solely with the CB using the cross-over technique is feasibly, safe, and was independently associated with a significantly higher freedom from recurrence of atrial tachyarrhythmias compared with PVI alone in patients with PerAF.
期刊介绍:
Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.