Accuracy of respiratory event indices downloaded from positive airway pressure devices: can they be relied upon when making treatment decisions?

IF 2.8 3区 医学 Q2 RESPIRATORY SYSTEM
Matthias Richter, Maik Schroeder, Georg Nilius
{"title":"Accuracy of respiratory event indices downloaded from positive airway pressure devices: can they be relied upon when making treatment decisions?","authors":"Matthias Richter, Maik Schroeder, Georg Nilius","doi":"10.1097/MCP.0000000000001113","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>The gold standard for diagnosis and treatment of obstructive sleep apnea (OSA) is attended overnight polysomnography (PSG) in a sleep laboratory. Alternative diagnostic techniques are urgently needed for both diagnosis and treatment control when initiating positive airway pressure (PAP) in the home setting. Current PAP devices compute data such as residual AHI (apnea-hypopnea index) using their proprietary algorithms to provide an automatic event detection (AED). It was suggested that these should be labeled AHIFLOW.</p><p><strong>Recent findings: </strong>The current study situation shows an acceptable agreement with the tendency of mildly overestimating the AHI by the PAP devices. But, the literature is still limited in terms of accuracy, especially when considering the lack of standardization and different detection algorithms.</p><p><strong>Summary: </strong>A validation of PAP devices regarding the agreement of AHIFLOW compared to AHIPSG is extremely important, given that the device analysis is exclusively based on the measured flow. There are considerable concerns about assessing the PAP effectiveness in higher risk groups based on the AED function alone. Given these reservations, the use of PAP event detection can be an important addition to the diagnostic spectrum and, in combination with telemonitoring, offers promising potential.</p>","PeriodicalId":11090,"journal":{"name":"Current Opinion in Pulmonary Medicine","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Opinion in Pulmonary Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MCP.0000000000001113","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose of review: The gold standard for diagnosis and treatment of obstructive sleep apnea (OSA) is attended overnight polysomnography (PSG) in a sleep laboratory. Alternative diagnostic techniques are urgently needed for both diagnosis and treatment control when initiating positive airway pressure (PAP) in the home setting. Current PAP devices compute data such as residual AHI (apnea-hypopnea index) using their proprietary algorithms to provide an automatic event detection (AED). It was suggested that these should be labeled AHIFLOW.

Recent findings: The current study situation shows an acceptable agreement with the tendency of mildly overestimating the AHI by the PAP devices. But, the literature is still limited in terms of accuracy, especially when considering the lack of standardization and different detection algorithms.

Summary: A validation of PAP devices regarding the agreement of AHIFLOW compared to AHIPSG is extremely important, given that the device analysis is exclusively based on the measured flow. There are considerable concerns about assessing the PAP effectiveness in higher risk groups based on the AED function alone. Given these reservations, the use of PAP event detection can be an important addition to the diagnostic spectrum and, in combination with telemonitoring, offers promising potential.

从气道正压设备下载的呼吸事件指数的准确性:在做出治疗决定时能否依赖这些指数?
审查目的:诊断和治疗阻塞性睡眠呼吸暂停(OSA)的黄金标准是在睡眠实验室进行夜间多导睡眠图(PSG)检查。在家庭环境中启动气道正压(PAP)时,急需其他诊断技术来进行诊断和治疗控制。目前的气道正压设备使用其专有算法计算残余 AHI(呼吸暂停-低通气指数)等数据,以提供自动事件检测 (AED)。有人建议这些设备应标注为 AHIFLOW:目前的研究结果表明,与 PAP 设备轻度高估 AHI 的趋势达成了可接受的一致。小结:鉴于 PAP 设备的分析完全基于测量的流量,因此对 PAP 设备的 AHIFLOW 与 AHIPSG 的一致性进行验证极为重要。仅根据自动体外除颤器的功能来评估 PAP 在高危人群中的有效性是相当令人担忧的。考虑到这些保留意见,PAP 事件检测的使用可以成为诊断范围的重要补充,并与远程监控相结合,具有广阔的前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
0.00%
发文量
109
审稿时长
6-12 weeks
期刊介绍: ​​​​​​Current Opinion in Pulmonary Medicine is a highly regarded journal offering insightful editorials and on-the-mark invited reviews, covering key subjects such as asthma; cystic fibrosis; infectious diseases; diseases of the pleura; and sleep and respiratory neurobiology. Published bimonthly, each issue of Current Opinion in Pulmonary Medicine introduces world renowned guest editors and internationally recognized academics within the pulmonary field, delivering a widespread selection of expert assessments on the latest developments from the most recent literature.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信