[Study on fatigue resistance of mechanical nickel-titanium files by phase-locked infrared flaw detection method].

Q4 Medicine
上海口腔医学 Pub Date : 2024-06-01
Zhuo-Guang Pu, Fu-Hua Zhang
{"title":"[Study on fatigue resistance of mechanical nickel-titanium files by phase-locked infrared flaw detection method].","authors":"Zhuo-Guang Pu, Fu-Hua Zhang","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The fatigue resistance of mechanical nickel-titanium files was tested by phase-locked infrared flaw detection method, in order to timely detect instrument wear, providing reference for clinical safe use and timely abandonment of nickel-titanium files.</p><p><strong>Methods: </strong>Twenty sets of mechanical nickel-titanium files were selected from Reciproc-Blue(RB), MTWO and S3 respectively, and resin simulated root canals with 60° and 90° bending were prepared, which were divided into 6 subgroups. The fatigue value after use, the number of uses before breaking and the length of fracture of file 25# of each group of files were recorded and compared with SPSS 26.0 software package.</p><p><strong>Results: </strong>With the increase of the times of use, the fatigue value of the three kinds of files increased gradually. Among the two types of curved root canals, the number of uses before fracture in RB group was significantly increased compared with that in MTWO group and S3 group (P<0.05). The number of uses of the three kinds of files in the 90° curved root canal were significantly less than in the corresponding groups in the 60° curved root canal(P<0.05). There was no significant difference in the length of fracture among the three kinds of files(P>0.05).</p><p><strong>Conclusions: </strong>Phase-locked infrared flaw detection method can be used for non-destructive testing and quantitative analysis of the fatigue degree of nickel-titanium files.</p>","PeriodicalId":21709,"journal":{"name":"上海口腔医学","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"上海口腔医学","FirstCategoryId":"3","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The fatigue resistance of mechanical nickel-titanium files was tested by phase-locked infrared flaw detection method, in order to timely detect instrument wear, providing reference for clinical safe use and timely abandonment of nickel-titanium files.

Methods: Twenty sets of mechanical nickel-titanium files were selected from Reciproc-Blue(RB), MTWO and S3 respectively, and resin simulated root canals with 60° and 90° bending were prepared, which were divided into 6 subgroups. The fatigue value after use, the number of uses before breaking and the length of fracture of file 25# of each group of files were recorded and compared with SPSS 26.0 software package.

Results: With the increase of the times of use, the fatigue value of the three kinds of files increased gradually. Among the two types of curved root canals, the number of uses before fracture in RB group was significantly increased compared with that in MTWO group and S3 group (P<0.05). The number of uses of the three kinds of files in the 90° curved root canal were significantly less than in the corresponding groups in the 60° curved root canal(P<0.05). There was no significant difference in the length of fracture among the three kinds of files(P>0.05).

Conclusions: Phase-locked infrared flaw detection method can be used for non-destructive testing and quantitative analysis of the fatigue degree of nickel-titanium files.

[利用锁相红外探伤法研究机械镍钛锉刀的抗疲劳性能]。
目的:采用锁相红外探伤法检测机械镍钛锉的抗疲劳性能,以便及时发现器械磨损情况,为临床安全使用和及时报废镍钛锉提供参考:分别从Reciproc-Blue(RB)、MTWO和S3中选取20套机械镍钛锉,制备60°和90°弯曲的树脂模拟根管,分为6个亚组。用 SPSS 26.0 软件包记录并比较各组锉使用后的疲劳值、锉25#断裂前的使用次数和断裂长度:随着使用次数的增加,三种锉刀的疲劳值逐渐增加。在两种类型的弯曲根管中,RB组在折断前的使用次数比MTWO组和S3组明显增加(P<0.05)。三种根管锉在 90° 弯曲根管中的使用次数均明显少于 60° 弯曲根管中的相应组别(P<0.05)。三种锉的折断长度无明显差异(P>0.05):锁相红外探伤法可用于镍钛锉疲劳度的无损检测和定量分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
上海口腔医学
上海口腔医学 Medicine-Medicine (all)
CiteScore
0.30
自引率
0.00%
发文量
5299
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信