Accuracy of lung ultrasound performed with handheld ultrasound device in internal medicine: an observational study.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal of Ultrasound Pub Date : 2024-12-01 Epub Date: 2024-08-03 DOI:10.1007/s40477-024-00941-5
Anna Lo Cricchio, Andrea Storelli, Iacopo Bertoletti, Gabriele Ciuti, Alessia Fabbri, Elisa Martinelli, Maria Cristina De Santis, Paolo Mercatelli, Khadija El Aoufy, Silvia Bellando Randone, Alberto Moggi Pignone, Esterita Accogli, Giulia Bandini
{"title":"Accuracy of lung ultrasound performed with handheld ultrasound device in internal medicine: an observational study.","authors":"Anna Lo Cricchio, Andrea Storelli, Iacopo Bertoletti, Gabriele Ciuti, Alessia Fabbri, Elisa Martinelli, Maria Cristina De Santis, Paolo Mercatelli, Khadija El Aoufy, Silvia Bellando Randone, Alberto Moggi Pignone, Esterita Accogli, Giulia Bandini","doi":"10.1007/s40477-024-00941-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Lung ultrasound (LUS) is increasingly used in Internal Medicine to complement medical examination, documenting pleural and lung conditions. This study aimed to compare the accuracy of handheld ultrasound device (HHUSD) with high-end ultrasound device (HEUSD) in patients with heart failure or pneumonia, also including the assessment of costs and time-savings.</p><p><strong>Methods: </strong>In this observational study 72 patients (aged ≥ 18) admitted to Internal Medicine Unit for heart failure or pneumonia underwent LUS plus evaluation of inferior cava vein (ICV) when indicated, using both HHUSD and HEUSD. Each evaluation, independently performed by 2 different experienced operators, included B-lines number, pleural effusion, lung consolidations, ICV ectasia and its respiratory excursions.</p><p><strong>Results: </strong>Concordance between HHUSD and HEUSD findings was 79.3% ± 17.7 (mean ± SD) for B-lines, 88.6% for pleural effusion, 82.3% for consolidations and 88.7% and 84.9% for ICV ectasia and its respiratory excursions respectively. BMI didn't significantly influence concordance between the two methods. Moreover, examination time (as mean ± SD) was shorter with HHUSD (8 ± 1.5 min) compared to HEUSD (10 ± 2.5 min).</p><p><strong>Conclusions: </strong>HHUSD demonstrated high accuracy in detecting B-lines, pleural effusions, lung consolidations and ICV evaluation when compared to HEUSD. Thus, HHUSD, not only is characterized by accessibility, portability, and easy handling due to its small size, but it also offers advantages in terms of saving costs and time, ultimately contributing to faster patient assessment compared to HEUSD.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11496455/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-024-00941-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Lung ultrasound (LUS) is increasingly used in Internal Medicine to complement medical examination, documenting pleural and lung conditions. This study aimed to compare the accuracy of handheld ultrasound device (HHUSD) with high-end ultrasound device (HEUSD) in patients with heart failure or pneumonia, also including the assessment of costs and time-savings.

Methods: In this observational study 72 patients (aged ≥ 18) admitted to Internal Medicine Unit for heart failure or pneumonia underwent LUS plus evaluation of inferior cava vein (ICV) when indicated, using both HHUSD and HEUSD. Each evaluation, independently performed by 2 different experienced operators, included B-lines number, pleural effusion, lung consolidations, ICV ectasia and its respiratory excursions.

Results: Concordance between HHUSD and HEUSD findings was 79.3% ± 17.7 (mean ± SD) for B-lines, 88.6% for pleural effusion, 82.3% for consolidations and 88.7% and 84.9% for ICV ectasia and its respiratory excursions respectively. BMI didn't significantly influence concordance between the two methods. Moreover, examination time (as mean ± SD) was shorter with HHUSD (8 ± 1.5 min) compared to HEUSD (10 ± 2.5 min).

Conclusions: HHUSD demonstrated high accuracy in detecting B-lines, pleural effusions, lung consolidations and ICV evaluation when compared to HEUSD. Thus, HHUSD, not only is characterized by accessibility, portability, and easy handling due to its small size, but it also offers advantages in terms of saving costs and time, ultimately contributing to faster patient assessment compared to HEUSD.

内科用手持超声设备进行肺部超声检查的准确性:一项观察性研究。
目的:肺部超声波(LUS)越来越多地用于内科辅助医学检查,记录胸膜和肺部情况。本研究旨在比较手持式超声设备(HHUSD)与高端超声设备(HEUSD)在心力衰竭或肺炎患者中的准确性,还包括对成本和节省时间的评估:在这项观察性研究中,72 名因心衰或肺炎入住内科病房的患者(年龄≥ 18 岁)同时使用 HHUSD 和 HEUSD 进行了 LUS 和下腔静脉 (ICV) 评估。每项评估均由两名经验丰富的操作员独立完成,包括 B 线数量、胸腔积液、肺部合并症、ICV 异位及其呼吸偏移:HHUSD和HEUSD结果的一致性分别为:B线为79.3%±17.7(平均值±标度),胸腔积液为88.6%,肺合并症为82.3%,ICV异位及其呼吸偏移为88.7%和84.9%。体重指数对两种方法的一致性没有明显影响。此外,与 HEUSD(10 ± 2.5 分钟)相比,HHUSD 的检查时间(平均值 ± SD)更短(8 ± 1.5 分钟):结论:与 HEUSD 相比,HHUSD 在检测 B 线、胸腔积液、肺部合并症和 ICV 评估方面具有很高的准确性。因此,与 HEUSD 相比,HHUSD 不仅具有方便、便携、体积小、易于操作等特点,还具有节省成本和时间的优势,最终有助于更快地评估患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Ultrasound
Journal of Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
15.00%
发文量
133
期刊介绍: The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信