{"title":"Validation of a Novel Method for Noninvasive Mixed Venous Oxygen Saturation Monitoring in Anesthetized Children.","authors":"Anders Svedmyr, Kristoffer Steiner, Andreas Andersson, Gunnar Sjöberg, Magnus Hallbäck, Mats Wallin, Per-Arne Lönnqvist, Jacob Karlsson","doi":"10.1213/ANE.0000000000007083","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Mixed venous oxygen saturation (SvO 2 ) is a critical variable in the assessment of oxygen supply and demand but is rarely used in children due to the invasive nature of pulmonary artery catheters. The aim of this prospective, observational study was to investigate the accuracy of noninvasively measured SvO 2 acquired by the novel capnodynamic method, based on differential Fick equation (Capno-SvO 2 ), against gold standard CO-oximetry.</p><p><strong>Methods: </strong>Capno-SvO 2 was compared to SvO 2 measured by pulmonary artery blood gas CO-oximetry in children undergoing cardiac catheter interventions and subjected to moderate hemodynamic challenges. Bland-Altman analysis was used to describe the agreement of absolute values between CO-oximetry and Capno-SvO 2 , and a concordance rate was calculated to evaluate the ability of Capno-SvO 2 to track change.</p><p><strong>Results: </strong>Twenty-five procedures were included in the study. Capno-SvO 2 showed a bias toward CO-oximetry of +3 percentage points; upper and lower limits of agreement were +11 percentage points (95% confidence interval [CI], 9-14) and -5 percentage points (95% CI, -8 to -3), respectively. The concordance rate was 92% (95% CI, 89-96).</p><p><strong>Conclusions: </strong>In conclusion, this first clinical application of a novel concept for noninvasive SvO 2 monitoring without the need for a pulmonary artery catheter indicates that Capno-SvO 2 generates absolute values and trending capacity in close agreement with the gold standard reference method.</p>","PeriodicalId":7784,"journal":{"name":"Anesthesia and analgesia","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anesthesia and analgesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1213/ANE.0000000000007083","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Mixed venous oxygen saturation (SvO 2 ) is a critical variable in the assessment of oxygen supply and demand but is rarely used in children due to the invasive nature of pulmonary artery catheters. The aim of this prospective, observational study was to investigate the accuracy of noninvasively measured SvO 2 acquired by the novel capnodynamic method, based on differential Fick equation (Capno-SvO 2 ), against gold standard CO-oximetry.

Methods: Capno-SvO 2 was compared to SvO 2 measured by pulmonary artery blood gas CO-oximetry in children undergoing cardiac catheter interventions and subjected to moderate hemodynamic challenges. Bland-Altman analysis was used to describe the agreement of absolute values between CO-oximetry and Capno-SvO 2 , and a concordance rate was calculated to evaluate the ability of Capno-SvO 2 to track change.

Results: Twenty-five procedures were included in the study. Capno-SvO 2 showed a bias toward CO-oximetry of +3 percentage points; upper and lower limits of agreement were +11 percentage points (95% confidence interval [CI], 9-14) and -5 percentage points (95% CI, -8 to -3), respectively. The concordance rate was 92% (95% CI, 89-96).

Conclusions: In conclusion, this first clinical application of a novel concept for noninvasive SvO 2 monitoring without the need for a pulmonary artery catheter indicates that Capno-SvO 2 generates absolute values and trending capacity in close agreement with the gold standard reference method.

麻醉儿童无创混合静脉血氧饱和度监测新方法的验证。
背景:混合静脉血氧饱和度(SvO2)是评估供氧和需氧的一个关键变量,但由于肺动脉导管的侵入性而很少用于儿童。这项前瞻性观察研究的目的是探讨基于费克微分方程的新型帽动力法(Capno-SvO2)与黄金标准二氧化碳氧饱和度测量法无创测量 SvO2 的准确性:方法:在接受心脏导管介入治疗和中度血流动力学挑战的儿童中,将 Capno-SvO2 与肺动脉血气 CO- 氧饱和度测量法测量的 SvO2 进行比较。使用 Bland-Altman 分析描述 CO- 氧饱和度与 Capno-SvO2 绝对值的一致性,并计算一致性率以评估 Capno-SvO2 跟踪变化的能力:结果:这项研究共纳入了 25 例手术。Capno-SvO2 与 CO-oximetry 的偏差为 +3 个百分点;一致性的上限和下限分别为 +11 个百分点(95% 置信区间 [CI],9-14)和 -5 个百分点(95% CI,-8--3)。一致率为 92% (95% CI, 89-96):总之,无需肺动脉导管的无创 SvO2 监测新概念的首次临床应用表明,Capno-SvO2 生成的绝对值和趋势能力与金标准参考方法非常接近。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Anesthesia and analgesia
Anesthesia and analgesia 医学-麻醉学
CiteScore
9.90
自引率
7.00%
发文量
817
审稿时长
2 months
期刊介绍: Anesthesia & Analgesia exists for the benefit of patients under the care of health care professionals engaged in the disciplines broadly related to anesthesiology, perioperative medicine, critical care medicine, and pain medicine. The Journal furthers the care of these patients by reporting the fundamental advances in the science of these clinical disciplines and by documenting the clinical, laboratory, and administrative advances that guide therapy. Anesthesia & Analgesia seeks a balance between definitive clinical and management investigations and outstanding basic scientific reports. The Journal welcomes original manuscripts containing rigorous design and analysis, even if unusual in their approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信