{"title":"Exploring the Influence of Reflectivity and Emissivity on Energy Consumption Across Varied Climate Zones in India","authors":"Rohit Thakur, Anil Kumar","doi":"10.1115/1.4066021","DOIUrl":null,"url":null,"abstract":"\n With a particular emphasis on sustainability, this research investigates the influence of reflectance and emissivity qualities on the amount of energy used by residential buildings of a mid-rise height located in various temperature zones in India. In the first part of the study, the impacts of highly reflecting, cool roofs were evaluated using base-case and proposed simulations. In the second phase, a comparison was made between the possible energy savings that may be obtained by switching from low to high solar reflective roofs. An analysis of the reflectance and emissivity characteristics of the roof was carried out with the assistance of the eQUEST simulation tool. The study findings were validated using the Bureau of Energy Efficiency (BEE) schedule for the residential building energy labeling program. According to the results, highly reflecting roofs, which have a reflectivity of 0.8 and an emissivity of 0.9, dramatically lowered cooling loads by 38% and 20% in hot and dry areas, 21-25% in composite climates, 17-25% in warm and humid climates, and 37% in colder climates. These cost-effective solutions could be applied to existing and new constructions and have the potential to provide large energy and monetary savings by improving the performance of the building envelope, which in turn contributes to efforts to make the building more environmentally friendly.","PeriodicalId":326594,"journal":{"name":"ASME Journal of Engineering for Sustainable Buildings and Cities","volume":" 565","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASME Journal of Engineering for Sustainable Buildings and Cities","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4066021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With a particular emphasis on sustainability, this research investigates the influence of reflectance and emissivity qualities on the amount of energy used by residential buildings of a mid-rise height located in various temperature zones in India. In the first part of the study, the impacts of highly reflecting, cool roofs were evaluated using base-case and proposed simulations. In the second phase, a comparison was made between the possible energy savings that may be obtained by switching from low to high solar reflective roofs. An analysis of the reflectance and emissivity characteristics of the roof was carried out with the assistance of the eQUEST simulation tool. The study findings were validated using the Bureau of Energy Efficiency (BEE) schedule for the residential building energy labeling program. According to the results, highly reflecting roofs, which have a reflectivity of 0.8 and an emissivity of 0.9, dramatically lowered cooling loads by 38% and 20% in hot and dry areas, 21-25% in composite climates, 17-25% in warm and humid climates, and 37% in colder climates. These cost-effective solutions could be applied to existing and new constructions and have the potential to provide large energy and monetary savings by improving the performance of the building envelope, which in turn contributes to efforts to make the building more environmentally friendly.
探索印度不同气候区反射率和发射率对能源消耗的影响
本研究以可持续发展为重点,调查了反射率和发射率质量对位于印度不同温度带的中层住宅建筑能源使用量的影响。在研究的第一部分,我们使用基本情况和建议的模拟方法评估了高反射、凉爽屋顶的影响。在第二阶段,比较了从低太阳反射屋顶到高太阳反射屋顶可能节省的能源。在 eQUEST 模拟工具的帮助下,对屋顶的反射率和发射率特性进行了分析。研究结果通过能源效率局(BEE)的住宅建筑能效标识计划表进行了验证。研究结果表明,反射率为 0.8 和发射率为 0.9 的高反射屋顶可显著降低干热地区 38% 和 20% 的制冷负荷,降低复合气候地区 21-25% 的制冷负荷,降低温暖潮湿气候地区 17-25% 的制冷负荷,降低寒冷气候地区 37% 的制冷负荷。这些具有成本效益的解决方案可应用于现有建筑和新建建筑,并有可能通过提高建筑围护结构的性能来节省大量能源和资金,进而促进建筑更加环保。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信