Auxetic Structure Inspired Microneedle Arrays for Minimally Invasive Drug Delivery

Maher Amer, Christina Fisher, Georgia Small, Blake Bullock, Vero Salinas, Jaden Langford
{"title":"Auxetic Structure Inspired Microneedle Arrays for Minimally Invasive Drug Delivery","authors":"Maher Amer, Christina Fisher, Georgia Small, Blake Bullock, Vero Salinas, Jaden Langford","doi":"10.1115/1.4066007","DOIUrl":null,"url":null,"abstract":"\n Microneedle Arrays (MNAs) are promising drug delivery tools aimed at lowering invasiveness and pain. Many design parameters are optimized to lower penetration force in MNAs. An important parameter is the microneedle width as that relates directly to the force required to penetrate the skin, the lower the width the lower the penetration force needed. This research explored the use of auxetic structures known for having negative Poisson ratios in the design of MNAs. As the needles are inserted the compression on the needles causes their radial dimension to shrink instead of increasing as in positive Poisson ration structures. This study has shown a 25% reduction in penetration force due to using an auxetic structure instead of a conventional non-auxetic structure. The research employs additive manufacturing and soft molding to fabricate the MNAs. This study emphasizes the viability of using auxetic structures in MNA design.","PeriodicalId":73734,"journal":{"name":"Journal of engineering and science in medical diagnostics and therapy","volume":"40 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of engineering and science in medical diagnostics and therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4066007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Microneedle Arrays (MNAs) are promising drug delivery tools aimed at lowering invasiveness and pain. Many design parameters are optimized to lower penetration force in MNAs. An important parameter is the microneedle width as that relates directly to the force required to penetrate the skin, the lower the width the lower the penetration force needed. This research explored the use of auxetic structures known for having negative Poisson ratios in the design of MNAs. As the needles are inserted the compression on the needles causes their radial dimension to shrink instead of increasing as in positive Poisson ration structures. This study has shown a 25% reduction in penetration force due to using an auxetic structure instead of a conventional non-auxetic structure. The research employs additive manufacturing and soft molding to fabricate the MNAs. This study emphasizes the viability of using auxetic structures in MNA design.
用于微创给药的磁性结构启发微针阵列
微针阵列(MNA)是一种很有前途的给药工具,旨在降低侵入性和疼痛。为了降低 MNA 的穿透力,对许多设计参数进行了优化。其中一个重要参数是微针宽度,因为它直接关系到穿透皮肤所需的力,宽度越小,所需的穿透力就越低。这项研究探索了在 MNA 设计中使用具有负泊松比的辅助结构。在插入针头时,针头受到的挤压会导致其径向尺寸缩小,而不是像正泊松比结构那样增大。这项研究表明,由于使用了辅助结构而不是传统的非辅助结构,穿刺力降低了 25%。研究采用了增材制造和软成型技术来制造 MNA。这项研究强调了在 MNA 设计中使用辅助结构的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信