The Effects of Axis-flip of the Refractive Cylinder on vision and patient reported outcome measures following Toric Intraocular Lens implantation.

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY
Khayam Naderi, Ashmal Jameel, Isabelle Chow, Chris Hull, David O'Brart
{"title":"The Effects of Axis-flip of the Refractive Cylinder on vision and patient reported outcome measures following Toric Intraocular Lens implantation.","authors":"Khayam Naderi, Ashmal Jameel, Isabelle Chow, Chris Hull, David O'Brart","doi":"10.1097/j.jcrs.0000000000001530","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the effects of cylinder axis-flip following toric intraocular lens (TIOL) implantation on vision and patient reported outcome measures (PROMs).</p><p><strong>Setting: </strong>Teaching hospital in the United Kingdom.</p><p><strong>Design: </strong>Post-hoc analysis of data from patients who participated in a prospective randomised study of TIOLs.</p><p><strong>Methods: </strong>Axis-flip was defined as a change in post-operative refractive cylinder axis of 900 +/- 22.50 from the pre-operative biometric axis. Uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BDVA), residual refractive cylinder (RC), and CATPROM-5 and EQ5D3L quality of life (QOL) scores were analysed.</p><p><strong>Results: </strong>At 6 months, axis flip occurred in 29 (34.5%) of 84 eyes, of which 28 had with-the-rule astigmatism (WTR) pre-operatively. Mean (+/-standard deviation) UDVA (logMAR) was 0.13 (0.16) in flipped cases (FC) and 0.10 (0.14) in un-flipped cases (UF) (p=0.88). BDVA was 0.01 (0.11) in FC and was 0.00 (0.09) in UF (p=0.68). Mean RC was 0.74 dioptres (D) (0.41) in FC and 0.93D (0.47) in UF (p=0.08). Mean CATPROM-5 score was -6.22.98 (2.56) in FC and -5.52 (3.03) in UF (p=0.29). Mean EQ5D3L calibrated score was 0.89 (0.19) in FC and 0.85 (0.19) in UF (p=0.35). Retrospectively applying coefficients of adjustment to account for posterior corneal astigmatism (PCA), suggested that 6 eyes (21%) of FC with WTR might have avoided axis-flip.</p><p><strong>Conclusions: </strong>Axis flipping following TIOL implantation did not adversely influence visual acuity or PROMs scores. Most FC had WTR pre-operatively. Adjusting for PCA might have reduced axis flip in some of these eyes.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556802/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001530","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the effects of cylinder axis-flip following toric intraocular lens (TIOL) implantation on vision and patient reported outcome measures (PROMs).

Setting: Teaching hospital in the United Kingdom.

Design: Post-hoc analysis of data from patients who participated in a prospective randomised study of TIOLs.

Methods: Axis-flip was defined as a change in post-operative refractive cylinder axis of 900 +/- 22.50 from the pre-operative biometric axis. Uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BDVA), residual refractive cylinder (RC), and CATPROM-5 and EQ5D3L quality of life (QOL) scores were analysed.

Results: At 6 months, axis flip occurred in 29 (34.5%) of 84 eyes, of which 28 had with-the-rule astigmatism (WTR) pre-operatively. Mean (+/-standard deviation) UDVA (logMAR) was 0.13 (0.16) in flipped cases (FC) and 0.10 (0.14) in un-flipped cases (UF) (p=0.88). BDVA was 0.01 (0.11) in FC and was 0.00 (0.09) in UF (p=0.68). Mean RC was 0.74 dioptres (D) (0.41) in FC and 0.93D (0.47) in UF (p=0.08). Mean CATPROM-5 score was -6.22.98 (2.56) in FC and -5.52 (3.03) in UF (p=0.29). Mean EQ5D3L calibrated score was 0.89 (0.19) in FC and 0.85 (0.19) in UF (p=0.35). Retrospectively applying coefficients of adjustment to account for posterior corneal astigmatism (PCA), suggested that 6 eyes (21%) of FC with WTR might have avoided axis-flip.

Conclusions: Axis flipping following TIOL implantation did not adversely influence visual acuity or PROMs scores. Most FC had WTR pre-operatively. Adjusting for PCA might have reduced axis flip in some of these eyes.

屈光圆柱轴翻转对散光人工晶体植入术后视力和患者报告结果的影响。
目的:研究散光眼内透镜(TIOL)植入术后柱轴翻转对视力和患者报告结果指标(PROMs)的影响:地点:英国教学医院:设计:对参与TIOL前瞻性随机研究的患者数据进行事后分析:方法:轴位翻转的定义是术后屈光圆柱轴位与术前生物测量轴位的变化达到 900 +/- 22.50。对未矫正远距离视力(UDVA)、最佳矫正远距离视力(BDVA)、残余屈光圆柱(RC)、CATPROM-5 和 EQ5D3L 生活质量(QOL)评分进行分析:6个月时,84只眼睛中有29只(34.5%)发生了轴翻转,其中28只术前有规则散光(WTR)。翻轴病例(FC)的平均(+/-标准偏差)UDVA(logMAR)为0.13(0.16),未翻轴病例(UF)为0.10(0.14)(P=0.88)。在 FC 中,BDVA 为 0.01(0.11),在 UF 中为 0.00(0.09)(p=0.68)。FC的平均RC为0.74D(0.41),UF为0.93D(0.47)(p=0.08)。FC 和 UF 的 CATPROM-5 平均得分分别为-6.22.98(2.56)和-5.52(3.03)(p=0.29)。EQ5D3L校准后的平均得分在功能组为0.89(0.19),在和睦组为0.85(0.19)(P=0.35)。追溯角膜后散光(PCA)的调整系数表明,6 只(21%)患有 WTR 的 FC 眼可能避免了轴向翻转:结论:TIOL植入术后轴翻转不会对视力或PROMs评分产生不利影响。大多数 FC 术前有 WTR。调整 PCA 可能会减少其中一些眼球的轴外翻。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信