{"title":"Hemodynamic effects of pulsatile frequency of right ventricular assist device (RVAD) on pulmonary perfusion: a simulation study.","authors":"Fan Meng, Yuanfei Zhu, Ming Yang","doi":"10.1007/s11517-024-03174-0","DOIUrl":null,"url":null,"abstract":"<p><p>Right ventricular assist devices (RVADs) have been extensively used to provide hemodynamic support for patients with end-stage right heart (RV) failure. However, conventional in-parallel RVADs can lead to an elevation of pulmonary artery (PA) pressure, consequently increasing the right ventricular (RV) afterload, which is unfavorable for the relaxation of cardiac muscles and reduction of valve complications. The aim of this study is to investigate the hemodynamic effects of the pulsatile frequency of the RVAD on pulmonary artery. Firstly, a mathematical model incorporating heart, systemic circulation, pulmonary circulation, and RVAD is developed to simulate the cardiovascular system. Subsequently, the frequency characteristics of the pulmonary circulation system are analyzed, and the calculated results demonstrate that the pulsatile frequency of the RVAD has a substantive impact on the pulmonary artery pressure. Finally, to verify the analysis results, the hemodynamic effects of the pulsatile frequency of the RVAD on pulmonary artery are compared under diffident support modes. It is found that the pulmonary artery pressure decreases by approximately 6% when the pulsatile frequency changes from 1 to 3 Hz. The increased pulsatile frequency of RA-PA support mode may facilitate the opening of the pulmonary valve, while the RV-PA support mode can more effectively reduce the load of RV. This work provides a useful method to decrease the pulmonary artery pressure during the RVAD supports and may be beneficial for improving myocardial function in patients with end-stage right heart failure, especially those with pulmonary hypertension.</p>","PeriodicalId":49840,"journal":{"name":"Medical & Biological Engineering & Computing","volume":" ","pages":"3875-3885"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical & Biological Engineering & Computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s11517-024-03174-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0
Abstract
Right ventricular assist devices (RVADs) have been extensively used to provide hemodynamic support for patients with end-stage right heart (RV) failure. However, conventional in-parallel RVADs can lead to an elevation of pulmonary artery (PA) pressure, consequently increasing the right ventricular (RV) afterload, which is unfavorable for the relaxation of cardiac muscles and reduction of valve complications. The aim of this study is to investigate the hemodynamic effects of the pulsatile frequency of the RVAD on pulmonary artery. Firstly, a mathematical model incorporating heart, systemic circulation, pulmonary circulation, and RVAD is developed to simulate the cardiovascular system. Subsequently, the frequency characteristics of the pulmonary circulation system are analyzed, and the calculated results demonstrate that the pulsatile frequency of the RVAD has a substantive impact on the pulmonary artery pressure. Finally, to verify the analysis results, the hemodynamic effects of the pulsatile frequency of the RVAD on pulmonary artery are compared under diffident support modes. It is found that the pulmonary artery pressure decreases by approximately 6% when the pulsatile frequency changes from 1 to 3 Hz. The increased pulsatile frequency of RA-PA support mode may facilitate the opening of the pulmonary valve, while the RV-PA support mode can more effectively reduce the load of RV. This work provides a useful method to decrease the pulmonary artery pressure during the RVAD supports and may be beneficial for improving myocardial function in patients with end-stage right heart failure, especially those with pulmonary hypertension.
期刊介绍:
Founded in 1963, Medical & Biological Engineering & Computing (MBEC) continues to serve the biomedical engineering community, covering the entire spectrum of biomedical and clinical engineering. The journal presents exciting and vital experimental and theoretical developments in biomedical science and technology, and reports on advances in computer-based methodologies in these multidisciplinary subjects. The journal also incorporates new and evolving technologies including cellular engineering and molecular imaging.
MBEC publishes original research articles as well as reviews and technical notes. Its Rapid Communications category focuses on material of immediate value to the readership, while the Controversies section provides a forum to exchange views on selected issues, stimulating a vigorous and informed debate in this exciting and high profile field.
MBEC is an official journal of the International Federation of Medical and Biological Engineering (IFMBE).