Comparison of probe tone and click stimulus at 226 Hz frequency on acoustic ımmittance measurement in normal hearing adults: a cross-sectional study

Füsun Sunar, Muhammed Pınar, Büşranur Şahin, Seda Nur Toksöz, İrem Nur Torun, Rabia Karabakan
{"title":"Comparison of probe tone and click stimulus at 226 Hz frequency on acoustic ımmittance measurement in normal hearing adults: a cross-sectional study","authors":"Füsun Sunar, Muhammed Pınar, Büşranur Şahin, Seda Nur Toksöz, İrem Nur Torun, Rabia Karabakan","doi":"10.1186/s43163-024-00634-0","DOIUrl":null,"url":null,"abstract":"Acoustic immittancemetry measurement is made using a probe tone or click stimulus at a frequency of 226 Hz, which is included in the audiological test battery. This study aims to compare tympanometric peak pressure (TPP), static acoustic admittance (Ytm), equivalent external ear canal volume (Vea) and tympanometric width (TW) values measured with probe tone and click stimulus at 226 Hz frequency. Measurements were made with a probe tone and click stimulus at frequency of 226 Hz in 60 ears of 30 adult individuals with normal hearing between the ages of 18–26. In the measurements TPP, Ytm, Vea and TW values were determined for both ears. In two different tympanogram measurement results using 226 Hz click stimulus and 226 Hz probe tone were a statistically significant difference was found between Ytm, Vea and TW values in the left ear (p < 0.05) and a statistically significant difference was found between Ytm and Vea values in the right ear (p < 0.05). There was no significant difference between the right ear TPP and TW values, left ear TPP value (p > 0.05). The current findings show that the comment of right and left ear tympanogram results should be evaluated according to two different measurement results using 226 Hz click stimulus and 226 Hz probe tone.","PeriodicalId":501131,"journal":{"name":"The Egyptian Journal of Otolaryngology","volume":"28 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Egyptian Journal of Otolaryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43163-024-00634-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Acoustic immittancemetry measurement is made using a probe tone or click stimulus at a frequency of 226 Hz, which is included in the audiological test battery. This study aims to compare tympanometric peak pressure (TPP), static acoustic admittance (Ytm), equivalent external ear canal volume (Vea) and tympanometric width (TW) values measured with probe tone and click stimulus at 226 Hz frequency. Measurements were made with a probe tone and click stimulus at frequency of 226 Hz in 60 ears of 30 adult individuals with normal hearing between the ages of 18–26. In the measurements TPP, Ytm, Vea and TW values were determined for both ears. In two different tympanogram measurement results using 226 Hz click stimulus and 226 Hz probe tone were a statistically significant difference was found between Ytm, Vea and TW values in the left ear (p < 0.05) and a statistically significant difference was found between Ytm and Vea values in the right ear (p < 0.05). There was no significant difference between the right ear TPP and TW values, left ear TPP value (p > 0.05). The current findings show that the comment of right and left ear tympanogram results should be evaluated according to two different measurement results using 226 Hz click stimulus and 226 Hz probe tone.
226 Hz 频率的探测音和点击刺激对正常听力成人声ı毫米脆度测量的影响比较:一项横断面研究
声阈测量是使用频率为 226 Hz 的探头音或点击刺激进行的,这也是听力测试中的一项内容。本研究旨在比较在 226 赫兹频率下使用探头音和点击刺激测量的鼓室峰压(TPP)、静态声导纳(Ytm)、等效外耳道容积(Vea)和鼓室宽度(TW)值。对 30 名听力正常、年龄在 18-26 岁之间的成年人的 60 只耳朵进行了频率为 226 Hz 的探头音和点击刺激测量。在测量中确定了双耳的 TPP、Ytm、Vea 和 TW 值。在使用 226 Hz 点击刺激和 226 Hz 探测音进行的两种不同鼓室图测量结果中,左耳的 Ytm、Vea 和 TW 值之间存在显著的统计学差异(P 0.05)。目前的研究结果表明,应根据使用 226 Hz 点击刺激和 226 Hz 探针音的两种不同测量结果来评估左右耳鼓室图结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信