{"title":"Generation of Indicators to Assess Quality of Health Care in Hospital at Home Through e-Delphi.","authors":"Carolina Puchi, Tatiana Paravic-Klijn, Alide Salazar","doi":"10.1097/QMH.0000000000000451","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>The quality of health care in hospital at home (HaH) has been measured in different countries using simple indicators and clinical results that only contribute to some dimensions of the quality of health care. We sought to generate indicators to comprehensively evaluate the quality of health care provided to HaH users through the e-Delphi technique.</p><p><strong>Methods: </strong>The e-Delphi technique was performed with the participation of 17 HaH experts. The methodological strategy applied in this study was divided into the following 3 phases: a preparatory phase; consultation phase; and consensus phase. Three rounds of consultations were conducted with experts. In round 1, they were asked to identify which aspects of HaH they believed should be evaluated using an indicator for each of the following 6 dimensions of health care quality: effectiveness; efficiency; timeliness; patient-centered care; equity; and safety. In round 2, they were asked to rate each indicator using a 5-point Likert-type scale with the following values: (1) Totally disagree; (2) Disagree; (3) Moderately agree; (4) Agree; and (5) Totally agree. The criteria for evaluating each indicator were as follows: (1) The indicator is a useful measure for assessing the quality of health care provided to HaH users. (2) The indicator is clearly and specifically written and does not require modification. (3) The indicator is essential and incorporates information that can be extracted from HaH program records. An indicator was considered approved if it received at least 65% approval from the expert panel for each evaluation criterion. In round 3, experts were asked to reassess their ratings, taking into account the opinions of the other experts. The reliability of this technique was ensured through credibility, reliability, and confirmability. We obtained ethical approval of the corresponding institutions and informed consent from the participating experts.</p><p><strong>Results: </strong>Nine unpublished and reliable indicators were generated. In addition, 13 indicators were incorporated that evaluate aspects previously analyzed by other authors and/or national and international institutions, which were adapted to be used in HaH. The total indicators generated (n = 22) represented all dimensions of the quality of health care: safety; opportunity; effectiveness; efficiency; equity; and patient-centered care.</p><p><strong>Conclusions: </strong>The 22 indicators generated through the e-Delphi technique permit a comprehensive evaluation of the quality of health care provided to HaH users.</p>","PeriodicalId":20986,"journal":{"name":"Quality Management in Health Care","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quality Management in Health Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/QMH.0000000000000451","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0
Abstract
Background and objectives: The quality of health care in hospital at home (HaH) has been measured in different countries using simple indicators and clinical results that only contribute to some dimensions of the quality of health care. We sought to generate indicators to comprehensively evaluate the quality of health care provided to HaH users through the e-Delphi technique.
Methods: The e-Delphi technique was performed with the participation of 17 HaH experts. The methodological strategy applied in this study was divided into the following 3 phases: a preparatory phase; consultation phase; and consensus phase. Three rounds of consultations were conducted with experts. In round 1, they were asked to identify which aspects of HaH they believed should be evaluated using an indicator for each of the following 6 dimensions of health care quality: effectiveness; efficiency; timeliness; patient-centered care; equity; and safety. In round 2, they were asked to rate each indicator using a 5-point Likert-type scale with the following values: (1) Totally disagree; (2) Disagree; (3) Moderately agree; (4) Agree; and (5) Totally agree. The criteria for evaluating each indicator were as follows: (1) The indicator is a useful measure for assessing the quality of health care provided to HaH users. (2) The indicator is clearly and specifically written and does not require modification. (3) The indicator is essential and incorporates information that can be extracted from HaH program records. An indicator was considered approved if it received at least 65% approval from the expert panel for each evaluation criterion. In round 3, experts were asked to reassess their ratings, taking into account the opinions of the other experts. The reliability of this technique was ensured through credibility, reliability, and confirmability. We obtained ethical approval of the corresponding institutions and informed consent from the participating experts.
Results: Nine unpublished and reliable indicators were generated. In addition, 13 indicators were incorporated that evaluate aspects previously analyzed by other authors and/or national and international institutions, which were adapted to be used in HaH. The total indicators generated (n = 22) represented all dimensions of the quality of health care: safety; opportunity; effectiveness; efficiency; equity; and patient-centered care.
Conclusions: The 22 indicators generated through the e-Delphi technique permit a comprehensive evaluation of the quality of health care provided to HaH users.
期刊介绍:
Quality Management in Health Care (QMHC) is a peer-reviewed journal that provides a forum for our readers to explore the theoretical, technical, and strategic elements of health care quality management. The journal''s primary focus is on organizational structure and processes as these affect the quality of care and patient outcomes. In particular, it:
-Builds knowledge about the application of statistical tools, control charts, benchmarking, and other devices used in the ongoing monitoring and evaluation of care and of patient outcomes;
-Encourages research in and evaluation of the results of various organizational strategies designed to bring about quantifiable improvements in patient outcomes;
-Fosters the application of quality management science to patient care processes and clinical decision-making;
-Fosters cooperation and communication among health care providers, payers and regulators in their efforts to improve the quality of patient outcomes;
-Explores links among the various clinical, technical, administrative, and managerial disciplines involved in patient care, as well as the role and responsibilities of organizational governance in ongoing quality management.