{"title":"Quantification of Calcium, Phosphorus, and Cerium in Novel Biocompatible Materials by Total Reflection X-Ray Fluorescence Spectroscopy","authors":"A. A. Samoilova, N. V. Petrakova, N. A. Andreeva, T. N. Penkina, S. G. Dorofeev, D. G. Filatova","doi":"10.1134/s0020168524700055","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Abstract</h3><p>An approach to determining the composition of new biocompatible materials based on cerium-containing calcium phosphates using the TXRF method is proposed. The ranges of analyte contents in solutions were determined for the correct determination of Ca, P, and Ce using the external reference method. A systematic underestimation of the calcium signal was noted when its content in the analyzed composite sample was above 30 mg/L. In order to assess the compliance of the sample with the thin layer criterion, an analysis of the Compton scattering spectra for the ceramic sample solution was carried out; the maximum value was 16.8 keV (96°). According to the plot of the mass attenuation coefficient for a film of a given composition, the attenuation of the intensity of the calcium line perpendicular to the substrate is not associated with absorption of the sample. Internal reference samples (Gd and Cu) were selected and conditions were found for determining micro- and macrocomponents in solutions and suspensions of samples. It has been shown that, when the calcium content in the sample is up to 50 mg/L, it is possible to correctly determine Ca, P, and Ce using the TXRF method in solutions and suspensions with <i>S</i><sub><i>r</i></sub> of 0.05 and 0.09, respectively. The convergence of the results obtained using the external and internal reference methods with appropriate dilutions of solutions and suspensions was noted.</p>","PeriodicalId":585,"journal":{"name":"Inorganic Materials","volume":"46 1","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Inorganic Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1134/s0020168524700055","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

An approach to determining the composition of new biocompatible materials based on cerium-containing calcium phosphates using the TXRF method is proposed. The ranges of analyte contents in solutions were determined for the correct determination of Ca, P, and Ce using the external reference method. A systematic underestimation of the calcium signal was noted when its content in the analyzed composite sample was above 30 mg/L. In order to assess the compliance of the sample with the thin layer criterion, an analysis of the Compton scattering spectra for the ceramic sample solution was carried out; the maximum value was 16.8 keV (96°). According to the plot of the mass attenuation coefficient for a film of a given composition, the attenuation of the intensity of the calcium line perpendicular to the substrate is not associated with absorption of the sample. Internal reference samples (Gd and Cu) were selected and conditions were found for determining micro- and macrocomponents in solutions and suspensions of samples. It has been shown that, when the calcium content in the sample is up to 50 mg/L, it is possible to correctly determine Ca, P, and Ce using the TXRF method in solutions and suspensions with Sr of 0.05 and 0.09, respectively. The convergence of the results obtained using the external and internal reference methods with appropriate dilutions of solutions and suspensions was noted.

Abstract Image

利用全反射 X 射线荧光光谱法量化新型生物兼容材料中的钙、磷和铈
摘要 提出了一种使用 TXRF 方法测定基于含钙磷酸盐的新型生物兼容材料成分的方法。使用外部参照法确定了溶液中分析物含量的范围,以便正确测定钙、磷和铈。当分析的复合样品中钙含量超过 30 mg/L 时,钙信号被系统性低估。为了评估样品是否符合薄层标准,对陶瓷样品溶液的康普顿散射光谱进行了分析;最大值为 16.8 keV (96°)。根据特定成分薄膜的质量衰减系数图,垂直于基底的钙线强度衰减与样品的吸收无关。选择了内部参考样品(钆和铜),并找到了测定样品溶液和悬浮液中微观和宏观成分的条件。结果表明,当样品中的钙含量高达 50 毫克/升时,使用 TXRF 方法可以在 Sr 分别为 0.05 和 0.09 的溶液和悬浮液中正确测定 Ca、P 和 Ce。在适当稀释溶液和悬浮液的情况下,使用外部和内部参考方法得出的结果趋于一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Inorganic Materials
Inorganic Materials 工程技术-材料科学:综合
CiteScore
1.40
自引率
25.00%
发文量
80
审稿时长
3-6 weeks
期刊介绍: Inorganic Materials is a journal that publishes reviews and original articles devoted to chemistry, physics, and applications of various inorganic materials including high-purity substances and materials. The journal discusses phase equilibria, including P–T–X diagrams, and the fundamentals of inorganic materials science, which determines preparatory conditions for compounds of various compositions with specified deviations from stoichiometry. Inorganic Materials is a multidisciplinary journal covering all classes of inorganic materials. The journal welcomes manuscripts from all countries in the English or Russian language.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信