Attachment Wear in Different Clear Aligner Therapy: A Comparative Study

IF 0.8 Q3 Pharmacology, Toxicology and Pharmaceutics
Kanuru Ravi Krishna, Kumar Adarsh, N. M. Krishna, Pragnya, Prince K Chacko, P. K. Varma Datla, Rahul V. C. Tiwari
{"title":"Attachment Wear in Different Clear Aligner Therapy: A Comparative Study","authors":"Kanuru Ravi Krishna, Kumar Adarsh, N. M. Krishna, Pragnya, Prince K Chacko, P. K. Varma Datla, Rahul V. C. Tiwari","doi":"10.4103/jpbs.jpbs_398_24","DOIUrl":null,"url":null,"abstract":"ABSTRACT\n \n \n \n Because of its ease and visual attractiveness, clear aligner therapy has grown in popularity as an orthodontic treatment option. On the other hand, the results of therapy may be impacted by attachment wear. Comparing attachment wear in three distinct clear aligner systems—System A, System B, and System C—was the goal of this investigation.\n \n \n \n The research comprised 60 individuals receiving clear aligners as part of their orthodontic treatment. Depending on whatever clear aligner system was being utilised, the patients were split into three groups. Attachment wear was evaluated using a standardised scoring method regularly. The various systems’ attachment wear was compared using statistical analysis.\n \n \n \n Compared to Systems B and C, System A showed less attachment wear. There were notable variations in attachment wear ratings between the systems. System C’s attachments had the most wear, whereas System A’s attachments had the least.\n \n \n \n Different clear aligner systems showed varying degrees of attachment wear, with System A exhibiting the least amount of wear. To maximise treatment procedures and guarantee treatment efficacy and longevity in clear aligner therapy, it is vital to comprehend attachment wear patterns.\n","PeriodicalId":16824,"journal":{"name":"Journal of Pharmacy and Bioallied Sciences","volume":"285 8","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmacy and Bioallied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jpbs.jpbs_398_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT Because of its ease and visual attractiveness, clear aligner therapy has grown in popularity as an orthodontic treatment option. On the other hand, the results of therapy may be impacted by attachment wear. Comparing attachment wear in three distinct clear aligner systems—System A, System B, and System C—was the goal of this investigation. The research comprised 60 individuals receiving clear aligners as part of their orthodontic treatment. Depending on whatever clear aligner system was being utilised, the patients were split into three groups. Attachment wear was evaluated using a standardised scoring method regularly. The various systems’ attachment wear was compared using statistical analysis. Compared to Systems B and C, System A showed less attachment wear. There were notable variations in attachment wear ratings between the systems. System C’s attachments had the most wear, whereas System A’s attachments had the least. Different clear aligner systems showed varying degrees of attachment wear, with System A exhibiting the least amount of wear. To maximise treatment procedures and guarantee treatment efficacy and longevity in clear aligner therapy, it is vital to comprehend attachment wear patterns.
不同透明矫治器疗法中的附着磨损:比较研究
摘要 透明矫治器疗法因其简便易行和视觉上的吸引力,已逐渐成为一种流行的正畸治疗方法。另一方面,治疗效果可能会受到附着磨损的影响。比较三种不同的透明矫治器系统(系统 A、系统 B 和系统 C)的附着磨损情况是本次调查的目标。 研究对象包括60名接受透明矫治器作为正畸治疗一部分的患者。根据所使用的透明矫治器系统,患者被分为三组。采用标准化的评分方法定期评估附着磨损情况。通过统计分析对各种系统的附着磨损情况进行比较。 与系统 B 和系统 C 相比,系统 A 的附着磨损较少。不同系统之间的附件磨损程度存在明显差异。系统C的附件磨损最严重,而系统A的附件磨损最轻。 不同的透明矫治器系统显示出不同程度的附着磨损,而系统A的磨损程度最小。为了最大限度地优化治疗程序,保证透明矫治器的治疗效果和使用寿命,了解附着体的磨损模式至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.50
自引率
0.00%
发文量
275
审稿时长
34 weeks
期刊介绍: Journal of Pharmacy And Bioallied Sciences is a Quarterly multidisciplinary open access biomedical journal. Journal of Pharmacy And Bioallied Sciences is an international medium of interaction between scientist, academicians and industrial personnel’s.JPBS is now offial publication of OPUBS.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信