An Ultrasonic Vibration Scratch Tester for Studying the Scratch Characteristics of Materials under Ultrasonic Vibration Contact Status

IF 2.2 3区 工程技术 Q2 ENGINEERING, MECHANICAL
Actuators Pub Date : 2024-07-11 DOI:10.3390/act13070262
Yaming Huang, Haoxiang Wu, Yuan Yao, Hongwei Zhao, Hu Huang
{"title":"An Ultrasonic Vibration Scratch Tester for Studying the Scratch Characteristics of Materials under Ultrasonic Vibration Contact Status","authors":"Yaming Huang, Haoxiang Wu, Yuan Yao, Hongwei Zhao, Hu Huang","doi":"10.3390/act13070262","DOIUrl":null,"url":null,"abstract":"Ultrasonic vibration-assisted machining is a promising technique for improving the removability of materials, especially for difficult-to-machine materials, but the material removal mechanism under ultrasonic vibration status is still far from clear. Scratch testing is generally employed to study the material removal mechanism, but currently, there is a lack of instruments capable of performing scratch testing under ultrasonic vibration. To address this gap, this study developed an ultrasonic vibration scratch tester that can perform quantitative ultrasonic vibration-assisted scratch (UVAS) testing of materials. A prototype was designed and fabricated, followed by characterizing its performance parameters. Comparative experiments of conventional scratch (CS) testing and UVAS testing were performed on AL1050 to investigate the effects of ultrasonic vibration on scratch characteristics, such as the scratch depth and coefficient of friction. It was found that compared to CS testing, UVAS testing, with an amplitude of 1.45 µm and a frequency of 20 kHz, achieved a maximum reduction in the coefficient of friction of approximately 22.5% and a maximum increase in the depth of the residual scratch of approximately 175%. These findings confirm the superiority of ultrasonic vibration-assisted machining and demonstrate the requirement for the development of ultrasonic vibration scratch testers.","PeriodicalId":48584,"journal":{"name":"Actuators","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Actuators","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/act13070262","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Ultrasonic vibration-assisted machining is a promising technique for improving the removability of materials, especially for difficult-to-machine materials, but the material removal mechanism under ultrasonic vibration status is still far from clear. Scratch testing is generally employed to study the material removal mechanism, but currently, there is a lack of instruments capable of performing scratch testing under ultrasonic vibration. To address this gap, this study developed an ultrasonic vibration scratch tester that can perform quantitative ultrasonic vibration-assisted scratch (UVAS) testing of materials. A prototype was designed and fabricated, followed by characterizing its performance parameters. Comparative experiments of conventional scratch (CS) testing and UVAS testing were performed on AL1050 to investigate the effects of ultrasonic vibration on scratch characteristics, such as the scratch depth and coefficient of friction. It was found that compared to CS testing, UVAS testing, with an amplitude of 1.45 µm and a frequency of 20 kHz, achieved a maximum reduction in the coefficient of friction of approximately 22.5% and a maximum increase in the depth of the residual scratch of approximately 175%. These findings confirm the superiority of ultrasonic vibration-assisted machining and demonstrate the requirement for the development of ultrasonic vibration scratch testers.
用于研究超声波振动接触状态下材料划痕特征的超声波振动划痕测试仪
超声波振动辅助加工是一种很有前途的提高材料可去除性的技术,特别是对于难加工材料,但超声波振动状态下的材料去除机理还很不清楚。一般采用划痕测试来研究材料去除机理,但目前缺乏能够在超声振动下进行划痕测试的仪器。针对这一空白,本研究开发了一种超声振动划痕测试仪,可对材料进行超声振动辅助划痕(UVAS)定量测试。研究人员设计并制造了一台原型机,随后对其性能参数进行了表征。在 AL1050 上进行了传统划痕(CS)测试和 UVAS 测试的对比实验,以研究超声振动对划痕深度和摩擦系数等划痕特性的影响。结果发现,与 CS 测试相比,振幅为 1.45 µm、频率为 20 kHz 的 UVAS 测试可最大降低摩擦系数约 22.5%,最大增加残余划痕深度约 175%。这些研究结果证实了超声波振动辅助加工的优越性,并证明了开发超声波振动划痕测试仪的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Actuators
Actuators Mathematics-Control and Optimization
CiteScore
3.90
自引率
15.40%
发文量
315
审稿时长
11 weeks
期刊介绍: Actuators (ISSN 2076-0825; CODEN: ACTUC3) is an international open access journal on the science and technology of actuators and control systems published quarterly online by MDPI.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信