A Derotational Corrective Osteotomy in a Torsional Malaligned Femoral Shaft Fracture Around a Prior Stuck Intramedullary Nail

IF 0.2 Q4 ORTHOPEDICS
Patricia R. Melvin, Conor O’Neill, Logan K. Laubach, J. Satpathy
{"title":"A Derotational Corrective Osteotomy in a Torsional Malaligned Femoral Shaft Fracture Around a Prior Stuck Intramedullary Nail","authors":"Patricia R. Melvin, Conor O’Neill, Logan K. Laubach, J. Satpathy","doi":"10.1097/bto.0000000000000674","DOIUrl":null,"url":null,"abstract":"\n \n Femoral torsional malunion following trauma fixed with intramedullary (IM) nailing can necessitate femoral derotational osteotomy based on the symptomatic limitations of the patient. There is a paucity of studies discussing the utility and methods of femoral derotational osteotomy following post-traumatic femoral torsional malunion fixed with IM nailing that is not removable.\n \n \n \n We report a surgical technique in a patient treated with a femoral derotational osteotomy who sustained significant rotational deformity after a femoral shaft fracture initially treated with antegrade IM nailing. A standard inferior patellar approach was performed. The distal interlocking screws of the nail were removed, and a trephine was placed up through the distal femoral canal around the nail to free the nail from the surrounding bone to allow for mobility of the distal femur following osteotomy. Parallel K-wires were placed above and below the cut level for rotational control. A dynamic compression plate was then placed in compression mode on the lateral aspect of the femur, and the distal interlocking screws were placed to lock the IM nail.\n \n \n \n We recommend this technique only be used in cases where the nail is centric in the intramedullary canal and in line with the trochlea to be able to pass the trephine through the knee. We believe this technique to be an effective surgical option to treat post-traumatic torsional deformities of the femur where hardware cannot be removed.\n","PeriodicalId":45336,"journal":{"name":"Techniques in Orthopaedics","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/bto.0000000000000674","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Femoral torsional malunion following trauma fixed with intramedullary (IM) nailing can necessitate femoral derotational osteotomy based on the symptomatic limitations of the patient. There is a paucity of studies discussing the utility and methods of femoral derotational osteotomy following post-traumatic femoral torsional malunion fixed with IM nailing that is not removable. We report a surgical technique in a patient treated with a femoral derotational osteotomy who sustained significant rotational deformity after a femoral shaft fracture initially treated with antegrade IM nailing. A standard inferior patellar approach was performed. The distal interlocking screws of the nail were removed, and a trephine was placed up through the distal femoral canal around the nail to free the nail from the surrounding bone to allow for mobility of the distal femur following osteotomy. Parallel K-wires were placed above and below the cut level for rotational control. A dynamic compression plate was then placed in compression mode on the lateral aspect of the femur, and the distal interlocking screws were placed to lock the IM nail. We recommend this technique only be used in cases where the nail is centric in the intramedullary canal and in line with the trochlea to be able to pass the trephine through the knee. We believe this technique to be an effective surgical option to treat post-traumatic torsional deformities of the femur where hardware cannot be removed.
对先前髓内钉卡住的扭转错位股骨粗隆骨折进行脱位矫正截骨术
使用髓内(IM)钉固定的创伤后股骨扭转错位患者可能需要根据症状限制进行股骨脱位截骨术。目前还很少有研究讨论用不可移除的 IM 钉固定创伤后股骨扭转错位后进行股骨脱位截骨术的实用性和方法。 我们报告了对一名股骨干骨折后出现明显旋转畸形的患者进行股骨脱位截骨治疗的手术技巧。手术采用标准的髌骨下入路。取出钉子的远端联锁螺钉,在钉子周围的股骨远端管内向上放置一根穿刺针,使钉子与周围骨质分离,以便截骨后股骨远端能够活动。在切口上下放置平行的 K 线,以控制旋转。然后在股骨外侧以加压模式放置动态加压板,并放置远端联锁螺钉以锁定 IM 钉。 我们建议只有在髓内钉位于髓内管中心且与蹄骨一致的情况下才可使用这种技术,以便将穿刺针穿过膝关节。我们认为这种技术是治疗股骨创伤后扭转畸形(硬件无法取出)的有效手术选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
31
期刊介绍: The purpose of Techniques in Orthopaedics is to provide information on the latest orthopaedic procedure as they are devised and used by top orthopaedic surgeons. The approach is technique-oriented, covering operations, manipulations, and instruments being developed and applied in such as arthroscopy, arthroplasty, and trauma. Each issue is guest-edited by an expert in the field and devoted to a single topic.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信