M. Bosco, Angela Fiamingo, M. Massimino, Pier Paolo Rossi
{"title":"An Assessment of the Seismic Performance of EC8-Compliant CBFs Taking into Account the Role of Soil: A Case Study","authors":"M. Bosco, Angela Fiamingo, M. Massimino, Pier Paolo Rossi","doi":"10.3390/buildings14072161","DOIUrl":null,"url":null,"abstract":"Based on criticisms raised in the past by researchers about the effectiveness of the design rules reported in the European seismic code for the design of concentrically braced frames, a new design procedure has been proposed and included in the upcoming version of Eurocode 8. The upcoming version of Eurocode 8 is in the enquiry stage. Hence, it is important to evaluate the effectiveness of the design procedure reported in the code using accurate numerical models and seismic inputs. In the present paper, a four-story building with concentrically braced frames in the chevron configuration is designed according to the upcoming version of Eurocode 8. A seismic performance assessment is carried out by the means of multiple-stripe analyses performed on refined numerical models. The seismic input is defined based on one-dimensional local site response analyses. The numerical analyses prove that the use of local site response analysis to properly account for the soil-filtering effects is of paramount importance, and that the design procedure reported in the upcoming version of Eurocode 8 for chevron concentrically braced frames leads to reasonably low probabilities of exceeding the considered limit states.","PeriodicalId":505657,"journal":{"name":"Buildings","volume":"48 17","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Buildings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/buildings14072161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Based on criticisms raised in the past by researchers about the effectiveness of the design rules reported in the European seismic code for the design of concentrically braced frames, a new design procedure has been proposed and included in the upcoming version of Eurocode 8. The upcoming version of Eurocode 8 is in the enquiry stage. Hence, it is important to evaluate the effectiveness of the design procedure reported in the code using accurate numerical models and seismic inputs. In the present paper, a four-story building with concentrically braced frames in the chevron configuration is designed according to the upcoming version of Eurocode 8. A seismic performance assessment is carried out by the means of multiple-stripe analyses performed on refined numerical models. The seismic input is defined based on one-dimensional local site response analyses. The numerical analyses prove that the use of local site response analysis to properly account for the soil-filtering effects is of paramount importance, and that the design procedure reported in the upcoming version of Eurocode 8 for chevron concentrically braced frames leads to reasonably low probabilities of exceeding the considered limit states.