Estimation of Groundwater Potential and Aquifer Protective Capacity Within Old Ikenga Hotel, Nsukka, Enugu State, Nigeria

Olisah N. C., Obiekezie T. N.
{"title":"Estimation of Groundwater Potential and Aquifer Protective Capacity Within Old Ikenga Hotel, Nsukka, Enugu State, Nigeria","authors":"Olisah N. C., Obiekezie T. N.","doi":"10.52589/ajensr-no8mpitk","DOIUrl":null,"url":null,"abstract":"A geophysical survey using electrical resistivity method was conducted around Old Ikenga Hotel, Nsukka in Enugu State, Nigeria to investigate the groundwater potential and aquifer protective capacity of the area. The project area lies within latitudes 6°50'4.0''N – 6°57'52.0\"N and longitudes 7°21'6.3\"E – 7°28'12.0\"E, and covers an area of about 89.6 km2. Vertical Electrical Soundings (VES) were carried out with a digital read out resistivity meter (ABEM SAS 1000). The VES points were marked at 25 m and 75 m along a 100 m line. A total of eight soundings were carried out in the area. The VES data collected were interpreted using INTERPEX software and the results presented in terms of resistivity, thickness, depth and lithology. The lithology was inferred by correlating the result to the lithology log of the borehole drilled in the hotel and the geology of the study area. The VES result shows lithologic layers varying from 4 to 5. Aquiferous sand and Aquiferous sandy shale constitute the aquifer units in the area at depth of 30.26 m to 188.20 m, with their thickness ranging from 30 m to 74 m as shown by their isopach map. The aquifer protective capacity was determined by calculating for longitudinal conductance and matching the values to known standards. The calculated longitudinal conductance varies from 0.0409 to 3.1235 mhos. The interpreted VES results reveal poor, moderate, good and very good aquifer protective capacities of the overburden layers.","PeriodicalId":404388,"journal":{"name":"African Journal of Environment and Natural Science Research","volume":"30 39","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Environment and Natural Science Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52589/ajensr-no8mpitk","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A geophysical survey using electrical resistivity method was conducted around Old Ikenga Hotel, Nsukka in Enugu State, Nigeria to investigate the groundwater potential and aquifer protective capacity of the area. The project area lies within latitudes 6°50'4.0''N – 6°57'52.0"N and longitudes 7°21'6.3"E – 7°28'12.0"E, and covers an area of about 89.6 km2. Vertical Electrical Soundings (VES) were carried out with a digital read out resistivity meter (ABEM SAS 1000). The VES points were marked at 25 m and 75 m along a 100 m line. A total of eight soundings were carried out in the area. The VES data collected were interpreted using INTERPEX software and the results presented in terms of resistivity, thickness, depth and lithology. The lithology was inferred by correlating the result to the lithology log of the borehole drilled in the hotel and the geology of the study area. The VES result shows lithologic layers varying from 4 to 5. Aquiferous sand and Aquiferous sandy shale constitute the aquifer units in the area at depth of 30.26 m to 188.20 m, with their thickness ranging from 30 m to 74 m as shown by their isopach map. The aquifer protective capacity was determined by calculating for longitudinal conductance and matching the values to known standards. The calculated longitudinal conductance varies from 0.0409 to 3.1235 mhos. The interpreted VES results reveal poor, moderate, good and very good aquifer protective capacities of the overburden layers.
尼日利亚埃努古州恩苏卡市老伊肯加酒店内地下水潜力和含水层保护能力估算
在尼日利亚埃努古州恩苏卡市老伊肯加酒店周围采用电阻率法进行了地球物理勘测,以调查该地区的地下水潜力和含水层保护能力。项目区位于北纬 6°50'4.0''- 6°57'52.0",东经 7°21'6.3"- 7°28'12.0",面积约 89.6 平方公里。使用数字读出电阻率仪(ABEM SAS 1000)进行了垂直电测深(VES)。VES 点分别标在 100 米线上 25 米和 75 米处。在该地区共进行了八次探测。使用 INTERPEX 软件对收集到的 VES 数据进行了解释,并根据电阻率、厚度、深度和岩性列出了结果。岩性是根据酒店钻孔的岩性记录和研究区域的地质情况推断出来的。VES 结果显示岩性层从 4 层到 5 层不等。含水层砂和含水层砂页岩构成了该地区的含水层单元,深度从 30.26 米到 188.20 米不等,等深线图显示其厚度从 30 米到 74 米不等。含水层的保护能力是通过计算纵向电导率并将数值与已知标准相匹配来确定的。计算得出的纵向电导从 0.0409 到 3.1235 mhos 不等。经解释的 VES 结果显示,覆盖层的含水层保护能力分别为差、中、好和很好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信