Silent Neonatal Incubators, Prototype Nica+

Acoustics Pub Date : 2024-07-15 DOI:10.3390/acoustics6030035
R. Hernández-Molina, Virginia Puyana-Romero, Juan Luis Beira-Jiménez, Arturo Morgado-Estévez, Rafael Bienvenido-Bárcena, Francisco Fernández-Zacarías
{"title":"Silent Neonatal Incubators, Prototype Nica+","authors":"R. Hernández-Molina, Virginia Puyana-Romero, Juan Luis Beira-Jiménez, Arturo Morgado-Estévez, Rafael Bienvenido-Bárcena, Francisco Fernández-Zacarías","doi":"10.3390/acoustics6030035","DOIUrl":null,"url":null,"abstract":"Objectives: The purpose of this study was to evaluate and compare the noise levels in current incubator models and a prototype designed to improve acoustic comfort in neonatal incubators. Methods: Tests were carried out on three different models of incubators and a prototype called Neonatal Incubator Acoustic Comfort Class (NICA). The tests measured both internal and external sound pressure levels under laboratory conditions. The noise index has been taken as the A-weighted equivalent continuous sound pressure level (LAeq,T) for a time interval of 1 min. Results: The results obtained show variations between the different models of incubators, although, overall, they are high values (around 56/60 dBA). The results prove that premature newborns under normal conditions of using these incubators are exposed to noise levels above international recommendations. The new incubator design minimizes noise generation and generates noise levels lower than international recommendations. Conclusions: The results obtained from the prototype (NICA+) show the effectiveness of the proposed design in improving acoustic comfort in neonatal incubators. The data show that the noise levels generated by the prototype under normal operating conditions are significantly lower than international recommendations.","PeriodicalId":502373,"journal":{"name":"Acoustics","volume":"31 50","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acoustics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/acoustics6030035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The purpose of this study was to evaluate and compare the noise levels in current incubator models and a prototype designed to improve acoustic comfort in neonatal incubators. Methods: Tests were carried out on three different models of incubators and a prototype called Neonatal Incubator Acoustic Comfort Class (NICA). The tests measured both internal and external sound pressure levels under laboratory conditions. The noise index has been taken as the A-weighted equivalent continuous sound pressure level (LAeq,T) for a time interval of 1 min. Results: The results obtained show variations between the different models of incubators, although, overall, they are high values (around 56/60 dBA). The results prove that premature newborns under normal conditions of using these incubators are exposed to noise levels above international recommendations. The new incubator design minimizes noise generation and generates noise levels lower than international recommendations. Conclusions: The results obtained from the prototype (NICA+) show the effectiveness of the proposed design in improving acoustic comfort in neonatal incubators. The data show that the noise levels generated by the prototype under normal operating conditions are significantly lower than international recommendations.
无声新生儿培养箱,原型 Nica+
研究目的本研究的目的是评估和比较现有培养箱型号的噪音水平和旨在改善新生儿培养箱声学舒适度的原型。方法:对三种不同型号的培养箱进行测试:对三种不同型号的培养箱和一种名为 "新生儿培养箱声学舒适度"(NICA)的原型进行了测试。测试在实验室条件下测量了内部和外部声压级。噪声指数是指时间间隔为 1 分钟的 A 加权等效连续声压级 (LAeq,T)。结果所获得的结果显示,不同型号的培养箱之间存在差异,但总体而言,它们的数值都很高(约 56/60 dBA)。结果证明,在正常使用这些培养箱的情况下,早产新生儿受到的噪音水平高于国际建议水平。新型婴儿培养箱的设计最大限度地减少了噪音的产生,其噪音水平低于国际建议值。结论从原型(NICA+)获得的结果表明,建议的设计能有效改善新生儿培养箱的声学舒适度。数据显示,原型在正常工作条件下产生的噪音水平明显低于国际建议水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信