A dosimetric evaluation of intensity modulated radiotherapy and three-dimensional conformal radiotherapy for prostate cancer in Ghana.

IF 1.2 Q4 ONCOLOGY
ecancermedicalscience Pub Date : 2024-05-31 eCollection Date: 2024-01-01 DOI:10.3332/ecancer.2024.1707
Kofi Adesi Kyei, Joseph Daniels, Ameyaw Kwame Adom, Philip Odonkor, Andrew Yaw Nyantakyi, Dorothy Ekua Adjabu
{"title":"A dosimetric evaluation of intensity modulated radiotherapy and three-dimensional conformal radiotherapy for prostate cancer in Ghana.","authors":"Kofi Adesi Kyei, Joseph Daniels, Ameyaw Kwame Adom, Philip Odonkor, Andrew Yaw Nyantakyi, Dorothy Ekua Adjabu","doi":"10.3332/ecancer.2024.1707","DOIUrl":null,"url":null,"abstract":"<p><p>External beam radiotherapy incorporates treatment techniques such as three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), image-guided radiotherapy and volumetric modulated arc therapy to deliver high-energy radiation to cancer. The use of IMRT for cancer treatment is also associated with significant costs for patients in low-middle-income countries. The purpose of this study was to compare the dosimetric properties of 3DCRT and IMRT treatment plans for the external beam irradiation of patients with prostate cancer (Pca) to ascertain the superiority of IMRT in terms of dose homogeneity, conformity and dose limitation to organs at risk (OAR) in a resource-limited setting. One hundred and sixty treatment plans for 80 patients were created using 3DCRT and IMRT on the Eclipse treatment planning system (version 13.6). Data were collected and assessed from the dose-volume histogram of each plan. The conformity and homogeneity index (HI) for each of the plans were calculated. The doses to the OAR were also recorded and evaluated. The mean HIs for the IMRT and 3DCRT treatment techniques were 0.04 ± 0.02 (range: 0.01-0.011) and 0.09 ± 0.02 (range: 0.04-0.016), respectively. The mean conformity index (CI) for IMRT and 3DCRT techniques were 1.257 ± 0.112 (range: 0.99-1.58) and 1.302 ± 0.196 (range: 1.10-2.26). IMRT had a better significant mean HI and CI compared to 3DCRT. Generally, for this study, IMRT had better organ sparing compared to 3DCRT. The mean doses for the OARs ranged from 4.3-74.6 Gy for IMRT and 3.1-75.9 Gy for the 3DCRT technique. Overall, this study demonstrates that IMRT may offer an enhanced therapeutic profile, potentially reducing toxicity to the patient and ensuring more precise dose delivery to the target volume compared to 3DCRT in PCa external beam irradiation.</p>","PeriodicalId":11460,"journal":{"name":"ecancermedicalscience","volume":"18 ","pages":"1707"},"PeriodicalIF":1.2000,"publicationDate":"2024-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11254402/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ecancermedicalscience","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3332/ecancer.2024.1707","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

External beam radiotherapy incorporates treatment techniques such as three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), image-guided radiotherapy and volumetric modulated arc therapy to deliver high-energy radiation to cancer. The use of IMRT for cancer treatment is also associated with significant costs for patients in low-middle-income countries. The purpose of this study was to compare the dosimetric properties of 3DCRT and IMRT treatment plans for the external beam irradiation of patients with prostate cancer (Pca) to ascertain the superiority of IMRT in terms of dose homogeneity, conformity and dose limitation to organs at risk (OAR) in a resource-limited setting. One hundred and sixty treatment plans for 80 patients were created using 3DCRT and IMRT on the Eclipse treatment planning system (version 13.6). Data were collected and assessed from the dose-volume histogram of each plan. The conformity and homogeneity index (HI) for each of the plans were calculated. The doses to the OAR were also recorded and evaluated. The mean HIs for the IMRT and 3DCRT treatment techniques were 0.04 ± 0.02 (range: 0.01-0.011) and 0.09 ± 0.02 (range: 0.04-0.016), respectively. The mean conformity index (CI) for IMRT and 3DCRT techniques were 1.257 ± 0.112 (range: 0.99-1.58) and 1.302 ± 0.196 (range: 1.10-2.26). IMRT had a better significant mean HI and CI compared to 3DCRT. Generally, for this study, IMRT had better organ sparing compared to 3DCRT. The mean doses for the OARs ranged from 4.3-74.6 Gy for IMRT and 3.1-75.9 Gy for the 3DCRT technique. Overall, this study demonstrates that IMRT may offer an enhanced therapeutic profile, potentially reducing toxicity to the patient and ensuring more precise dose delivery to the target volume compared to 3DCRT in PCa external beam irradiation.

加纳前列腺癌调强放射治疗和三维适形放射治疗的剂量学评估。
体外放射治疗结合了三维适形放射治疗(3DCRT)、调强放射治疗(IMRT)、图像引导放射治疗和容积调强弧线治疗等治疗技术,向癌症提供高能量辐射。对于中低收入国家的患者来说,使用 IMRT 治疗癌症也会产生大量费用。本研究的目的是比较 3DCRT 和 IMRT 治疗方案对前列腺癌患者进行体外照射的剂量特性,以确定在资源有限的情况下,IMRT 在剂量均匀性、一致性和对危险器官(OAR)的剂量限制方面的优越性。在 Eclipse 治疗计划系统(13.6 版)上使用 3DCRT 和 IMRT 为 80 名患者创建了 160 个治疗计划。根据每个计划的剂量-体积直方图收集和评估数据。计算每个计划的符合性和均匀性指数(HI)。同时还记录并评估了OAR的剂量。IMRT 和 3DCRT 治疗技术的平均 HI 分别为 0.04 ± 0.02(范围:0.01-0.011)和 0.09 ± 0.02(范围:0.04-0.016)。IMRT和3DCRT技术的平均符合性指数(CI)分别为1.257±0.112(范围:0.99-1.58)和1.302±0.196(范围:1.10-2.26)。与 3DCRT 相比,IMRT 的平均 HI 和 CI 显着性更好。总体而言,在这项研究中,IMRT与3DCRT相比具有更好的器官疏通效果。IMRT的OARs平均剂量为4.3-74.6 Gy,3DCRT技术为3.1-75.9 Gy。总之,这项研究表明,在 PCa 外照射中,与 3DCRT 相比,IMRT 可提供更好的治疗效果,减少对患者的潜在毒性,并确保更精确地将剂量输送到靶区。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.80
自引率
5.60%
发文量
138
审稿时长
27 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信