Esther Schimanski, Thomas Lenarz, Susan Busch, Susan Arndt, Christian Offergeld, Christoph Arnoldner, Dominik Riss, Joachim Hornung, Lava Taha, Paul Martin Zwittag, Nina Rubicz, Dirk Beutner, Nicholas Bevis, Benjamin Loader, Franz Windisch, Georg Sprinzl, Astrid Magele, Wendelin Wolfram, Lisa Niederwanger, Łukasz Plichta, Piotr H Skarżyński
{"title":"Safety and performance of the new med-el total ossicular replacement prostheses.","authors":"Esther Schimanski, Thomas Lenarz, Susan Busch, Susan Arndt, Christian Offergeld, Christoph Arnoldner, Dominik Riss, Joachim Hornung, Lava Taha, Paul Martin Zwittag, Nina Rubicz, Dirk Beutner, Nicholas Bevis, Benjamin Loader, Franz Windisch, Georg Sprinzl, Astrid Magele, Wendelin Wolfram, Lisa Niederwanger, Łukasz Plichta, Piotr H Skarżyński","doi":"10.1007/s00405-024-08784-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This multicentric, retrospective study provides safety and performance data of the MED-EL total ossicular replacement prostheses (TORP).</p><p><strong>Methods: </strong>Patients underwent tympanoplasty with mXACT Total Prosthesis Center, mXACT Total Prosthesis Offcenter or mXACT PRO Total Prosthesis. The clinical data were retrospectively analyzed. Follow-up examination included access to the medical record (for adverse events) of the patients, ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA<sub>4</sub>). The post-operative PTA<sub>4</sub> air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined.</p><p><strong>Results: </strong>103 patients were implanted with a TORP. 102 (88 adults, 14 children; 37 CHL, 64 MHL, 1 not specified) patients were analyzed for safety and 92 (79 adults, 13 children) patients for performance of the prostheses. ADVERSE EVENTS RESULTS (N = 102): In 1 patient (child, mXACT Total Prosthesis Offcenter) a prosthesis dislocation was reported, which lead to a revision surgery. No prosthesis extrusion or migration was reported. AUDIOLOGICAL RESULTS (N = 92): 49 (53.3%) of the 92 patients had a PTA<sub>4</sub> ABG of ≤ 20 dB and therefore a successful rehabilitation. The mean post-operative PTA<sub>4</sub> ABG of all 92 patients was 21.0 ± 9.7 dB. The first endpoint, improvement in post-operative PTA<sub>4</sub> ABG of ≤ 20 dB by ≥ 25% of the patients was achieved. The individual Δ BC PTA<sub>4</sub> (post-operative minus pre-operative BC PTA<sub>4</sub>) thresholds were stable (within ± 5 dB HL) in 91 (98.9%) patients. 1 patient had a BC PTA<sub>4</sub> deterioration of 11.3 dB HL.</p><p><strong>Conclusion: </strong>The MED-EL TORPs are safe and effective for middle ear reconstruction. Trial registration number NCT05565339, September 09, 2022, retrospectively registered.</p>","PeriodicalId":11952,"journal":{"name":"European Archives of Oto-Rhino-Laryngology","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Archives of Oto-Rhino-Laryngology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00405-024-08784-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/13 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This multicentric, retrospective study provides safety and performance data of the MED-EL total ossicular replacement prostheses (TORP).
Methods: Patients underwent tympanoplasty with mXACT Total Prosthesis Center, mXACT Total Prosthesis Offcenter or mXACT PRO Total Prosthesis. The clinical data were retrospectively analyzed. Follow-up examination included access to the medical record (for adverse events) of the patients, ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4). The post-operative PTA4 air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined.
Results: 103 patients were implanted with a TORP. 102 (88 adults, 14 children; 37 CHL, 64 MHL, 1 not specified) patients were analyzed for safety and 92 (79 adults, 13 children) patients for performance of the prostheses. ADVERSE EVENTS RESULTS (N = 102): In 1 patient (child, mXACT Total Prosthesis Offcenter) a prosthesis dislocation was reported, which lead to a revision surgery. No prosthesis extrusion or migration was reported. AUDIOLOGICAL RESULTS (N = 92): 49 (53.3%) of the 92 patients had a PTA4 ABG of ≤ 20 dB and therefore a successful rehabilitation. The mean post-operative PTA4 ABG of all 92 patients was 21.0 ± 9.7 dB. The first endpoint, improvement in post-operative PTA4 ABG of ≤ 20 dB by ≥ 25% of the patients was achieved. The individual Δ BC PTA4 (post-operative minus pre-operative BC PTA4) thresholds were stable (within ± 5 dB HL) in 91 (98.9%) patients. 1 patient had a BC PTA4 deterioration of 11.3 dB HL.
Conclusion: The MED-EL TORPs are safe and effective for middle ear reconstruction. Trial registration number NCT05565339, September 09, 2022, retrospectively registered.
期刊介绍:
Official Journal of
European Union of Medical Specialists – ORL Section and Board
Official Journal of Confederation of European Oto-Rhino-Laryngology Head and Neck Surgery
"European Archives of Oto-Rhino-Laryngology" publishes original clinical reports and clinically relevant experimental studies, as well as short communications presenting new results of special interest. With peer review by a respected international editorial board and prompt English-language publication, the journal provides rapid dissemination of information by authors from around the world. This particular feature makes it the journal of choice for readers who want to be informed about the continuing state of the art concerning basic sciences and the diagnosis and management of diseases of the head and neck on an international level.
European Archives of Oto-Rhino-Laryngology was founded in 1864 as "Archiv für Ohrenheilkunde" by A. von Tröltsch, A. Politzer and H. Schwartze.