Multiobjective optimization guided by image quality index for limited-angle CT image reconstruction.

IF 1.7 3区 医学 Q3 INSTRUMENTS & INSTRUMENTATION
Yu He, Chengxiang Wang, Wei Yu, Jiaxi Wang
{"title":"Multiobjective optimization guided by image quality index for limited-angle CT image reconstruction.","authors":"Yu He, Chengxiang Wang, Wei Yu, Jiaxi Wang","doi":"10.3233/XST-240111","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Due to the incomplete projection data collected by limited-angle computed tomography (CT), severe artifacts are present in the reconstructed image. Classical regularization methods such as total variation (TV) minimization, ℓ0 minimization, are unable to suppress artifacts at the edges perfectly. Most existing regularization methods are single-objective optimization approaches, stemming from scalarization methods for multiobjective optimization problems (MOP).</p><p><strong>Objective: </strong>To further suppress the artifacts and effectively preserve the edge structures of the reconstructed image.</p><p><strong>Method: </strong>This study presents a multiobjective optimization model incorporates both data fidelity term and ℓ0-norm of the image gradient as objective functions. It employs an iterative approach different from traditional scalarization methods, using the maximization of structural similarity (SSIM) values to guide optimization rather than minimizing the objective function.The iterative method involves two steps, firstly, simultaneous algebraic reconstruction technique (SART) optimizes the data fidelity term using SSIM and the Simulated Annealing (SA) algorithm for guidance. The degradation solution is accepted in the form of probability, and guided image filtering (GIF) is introduced to further preserve the image edge when the degradation solution is rejected. Secondly, the result from the first step is integrated into the second objective function as a constraint, we use ℓ0 minimization to optimize ℓ0-norm of the image gradient, and the SSIM, SA algorithm and GIF are introduced to guide optimization process by improving SSIM value like the first step.</p><p><strong>Results: </strong>With visual inspection, the peak signal-to-noise ratio (PSNR), root mean square error (RMSE), and SSIM values indicate that our approach outperforms other traditional methods.</p><p><strong>Conclusions: </strong>The experiments demonstrate the effectiveness of our method and its superiority over other classical methods in artifact suppression and edge detail restoration.</p>","PeriodicalId":49948,"journal":{"name":"Journal of X-Ray Science and Technology","volume":" ","pages":"1209-1237"},"PeriodicalIF":1.7000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of X-Ray Science and Technology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/XST-240111","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Due to the incomplete projection data collected by limited-angle computed tomography (CT), severe artifacts are present in the reconstructed image. Classical regularization methods such as total variation (TV) minimization, ℓ0 minimization, are unable to suppress artifacts at the edges perfectly. Most existing regularization methods are single-objective optimization approaches, stemming from scalarization methods for multiobjective optimization problems (MOP).

Objective: To further suppress the artifacts and effectively preserve the edge structures of the reconstructed image.

Method: This study presents a multiobjective optimization model incorporates both data fidelity term and ℓ0-norm of the image gradient as objective functions. It employs an iterative approach different from traditional scalarization methods, using the maximization of structural similarity (SSIM) values to guide optimization rather than minimizing the objective function.The iterative method involves two steps, firstly, simultaneous algebraic reconstruction technique (SART) optimizes the data fidelity term using SSIM and the Simulated Annealing (SA) algorithm for guidance. The degradation solution is accepted in the form of probability, and guided image filtering (GIF) is introduced to further preserve the image edge when the degradation solution is rejected. Secondly, the result from the first step is integrated into the second objective function as a constraint, we use ℓ0 minimization to optimize ℓ0-norm of the image gradient, and the SSIM, SA algorithm and GIF are introduced to guide optimization process by improving SSIM value like the first step.

Results: With visual inspection, the peak signal-to-noise ratio (PSNR), root mean square error (RMSE), and SSIM values indicate that our approach outperforms other traditional methods.

Conclusions: The experiments demonstrate the effectiveness of our method and its superiority over other classical methods in artifact suppression and edge detail restoration.

以图像质量指标为指导,对有限角度 CT 图像重建进行多目标优化。
背景:由于有限角度计算机断层扫描(CT)收集的投影数据不完整,重建图像中会出现严重的伪影。经典的正则化方法(如总变异(TV)最小化、ℓ0 最小化)无法完美抑制边缘的伪影。现有的大多数正则化方法都是单目标优化方法,源于多目标优化问题(MOP)的标量化方法:目标:进一步抑制伪影,有效保留重建图像的边缘结构:本研究提出了一种多目标优化模型,将数据保真度项和图像梯度的 ℓ0-norm 作为目标函数。该迭代法包括两个步骤:首先,同步代数重建技术(SART)利用结构相似性最大化(SSIM)值来优化数据保真度项,并以模拟退火(SA)算法为指导。降解方案以概率的形式被接受,当降解方案被拒绝时,引入引导图像滤波(GIF)以进一步保留图像边缘。其次,将第一步的结果整合到第二个目标函数中作为约束条件,我们使用 ℓ0 最小化来优化图像梯度的 ℓ0 正态,并引入 SSIM、SA 算法和 GIF,像第一步一样通过提高 SSIM 值来指导优化过程:通过目测,峰值信噪比(PSNR)、均方根误差(RMSE)和 SSIM 值表明,我们的方法优于其他传统方法:实验证明,我们的方法非常有效,在抑制伪影和恢复边缘细节方面优于其他传统方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.90
自引率
23.30%
发文量
150
审稿时长
3 months
期刊介绍: Research areas within the scope of the journal include: Interaction of x-rays with matter: x-ray phenomena, biological effects of radiation, radiation safety and optical constants X-ray sources: x-rays from synchrotrons, x-ray lasers, plasmas, and other sources, conventional or unconventional Optical elements: grazing incidence optics, multilayer mirrors, zone plates, gratings, other diffraction optics Optical instruments: interferometers, spectrometers, microscopes, telescopes, microprobes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信