Jawad Iqbal Rather, Khalid P Sofi, Muzamil Ahmad Wani, Muzafar Maqsood Wani, Rabiya Rasheed, Mohammad Ashraf Bhat, Imtiyaz Ahmad Wani
{"title":"Ambulatory Blood Pressure Monitoring versus Office Blood Pressure Monitoring to Identify the True Hypertension Status of Living Kidney Donors.","authors":"Jawad Iqbal Rather, Khalid P Sofi, Muzamil Ahmad Wani, Muzafar Maqsood Wani, Rabiya Rasheed, Mohammad Ashraf Bhat, Imtiyaz Ahmad Wani","doi":"10.4103/sjkdt.sjkdt_256_23","DOIUrl":null,"url":null,"abstract":"<p><p>Ambulatory blood pressure monitoring (ABPM) is a reliable modality and is preferred over office blood pressure monitoring (OBPM) for detecting hypertension. However, despite its advantages, the utilization of 24-h ABPM in evaluating living kidney donors has not been universally adopted by transplant centers, partly because of the lack of data about the utility of ABPM. This study aimed to identify patients with masked and white-coat hypertension, thereby ensuring appropriate identification of their true hypertension status and assessments of the risk to donors. This study included 73 potential living kidney donors. BP was measured in the office using a standardized protocol as well as by ABPM. Detailed clinical and biochemical parameters were assessed. Target organ damage was assessed in all the donors by assessing proteinuria, hypertensive retinopathy, and echocardiography. Out of the 73 donors, 64.4% were females and 35.6% were males. The average age of individuals in our donor population was 42.0 ± 11.28 years. In total, 31.5% were detected to be hypertensive by OBPM. With ABPM, only 21.9% of donors were hypertensive. The overall prevalence of white-coat hypertension was 30.4%; that of masked hypertension was 6.0%. In donors diagnosed as hypertensive by OBPM, three individuals were identified as having target organ damage. However, two additional donors who were initially missed as hypertensive using OBPM had target organ damage. OBPM overestimated the prevalence of hypertension compared with ABPM. ABPM is the better modality in terms of diagnosing white coats and masked hypertension. ABPM also more reliably correlates with target organ damage than OBPM.</p>","PeriodicalId":21356,"journal":{"name":"Saudi Journal of Kidney Diseases and Transplantation","volume":"34 Suppl 1","pages":"S24-S30"},"PeriodicalIF":0.5000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Journal of Kidney Diseases and Transplantation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/sjkdt.sjkdt_256_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/3 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Ambulatory blood pressure monitoring (ABPM) is a reliable modality and is preferred over office blood pressure monitoring (OBPM) for detecting hypertension. However, despite its advantages, the utilization of 24-h ABPM in evaluating living kidney donors has not been universally adopted by transplant centers, partly because of the lack of data about the utility of ABPM. This study aimed to identify patients with masked and white-coat hypertension, thereby ensuring appropriate identification of their true hypertension status and assessments of the risk to donors. This study included 73 potential living kidney donors. BP was measured in the office using a standardized protocol as well as by ABPM. Detailed clinical and biochemical parameters were assessed. Target organ damage was assessed in all the donors by assessing proteinuria, hypertensive retinopathy, and echocardiography. Out of the 73 donors, 64.4% were females and 35.6% were males. The average age of individuals in our donor population was 42.0 ± 11.28 years. In total, 31.5% were detected to be hypertensive by OBPM. With ABPM, only 21.9% of donors were hypertensive. The overall prevalence of white-coat hypertension was 30.4%; that of masked hypertension was 6.0%. In donors diagnosed as hypertensive by OBPM, three individuals were identified as having target organ damage. However, two additional donors who were initially missed as hypertensive using OBPM had target organ damage. OBPM overestimated the prevalence of hypertension compared with ABPM. ABPM is the better modality in terms of diagnosing white coats and masked hypertension. ABPM also more reliably correlates with target organ damage than OBPM.
期刊介绍:
Saudi Journal of Kidney Diseases and Transplantation (SJKDT, ISSN 1319-2442) is the official publication of the Saudi Center for Organ Transplantation, Riyadh, Saudi Arabia. It is published six times a year. SJKDT publishes peer-reviewed original research work and review papers related to kidney diseases, urinary tract, renal replacement therapies, and transplantation. The journal publishes original papers and reviews on cell therapy and islet transplantation, clinical transplantation, experimental transplantation, immunobiology and genomics and xenotransplantation related to the kidney. The journal also publishes short communications, case studies, letters to the editors, an annotated bibliography and a column on news and views.