Impact of 12-Month Angioscopic Thrombi and Yellow Plaque After Drug-Eluting Stent Implantation.

IF 3.1 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Masami Nishino, Yasuyuki Egami, Hiroaki Nohara, Shodai Kawanami, Kohei Ukita, Akito Kawamura, Koji Yasumoto, Naotaka Okamoto, Yasuharu Matsunaga-Lee, Masamichi Yano, Tatsuya Shiraki, Daisuke Nakamura, Isamu Mizote, Takayuki Ishihara, Toshiaki Mano, Takafumi Ueno, Daisaku Nakatani, Shungo Hikoso, Shinsuke Nanto, Yasushi Sakata
{"title":"Impact of 12-Month Angioscopic Thrombi and Yellow Plaque After Drug-Eluting Stent Implantation.","authors":"Masami Nishino, Yasuyuki Egami, Hiroaki Nohara, Shodai Kawanami, Kohei Ukita, Akito Kawamura, Koji Yasumoto, Naotaka Okamoto, Yasuharu Matsunaga-Lee, Masamichi Yano, Tatsuya Shiraki, Daisuke Nakamura, Isamu Mizote, Takayuki Ishihara, Toshiaki Mano, Takafumi Ueno, Daisaku Nakatani, Shungo Hikoso, Shinsuke Nanto, Yasushi Sakata","doi":"10.1253/circj.CJ-24-0255","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Coronary angioscopy (CAS) has 2 unique abilities: direct visualization of thrombi and plaque color. However, in the recent drug-eluting stent (DES) era, serial CAS findings after DES implantation have not been fully elucidated. We investigated the impact of CAS findings after implantation of a polymer-free biolimus A9-coated stent (PF-BCS) or durable polymer everolimus-eluting stent (DP-EES).Methods and Results: We investigated serial CAS and optical coherence tomography (OCT) findings at 1 and 12 months in 99 patients who underwent PF-BCS or DP-EES implantation. We evaluated factors correlated with angioscopic thrombi and yellow plaque, and the clinical impact of both thrombi and yellow plaque at 12 months (BTY). The BTY group included 17 (22%) patients. The incidence and grade of thrombi and yellow plaque decreased from 1 to 12 months. Although no patients had newly appearing thrombi at 12 months, 2 DP-EES patients had newly appearing yellow plaque at 12 months. Multivariable analysis revealed HbA1c, minimum stent area, and adequate strut coverage were significant factors correlated with 12-month angioscopic thrombi, and DP-EESs were significantly correlated with 12-month yellow plaque. However, BTY was not correlated with clinical events.</p><p><strong>Conclusions: </strong>The management of diabetes, stent area, and adequate stent coverage are important for intrastent thrombogenicity and polymer-free stents are useful for stabilizing plaque vulnerability.</p>","PeriodicalId":50691,"journal":{"name":"Circulation Journal","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1253/circj.CJ-24-0255","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Coronary angioscopy (CAS) has 2 unique abilities: direct visualization of thrombi and plaque color. However, in the recent drug-eluting stent (DES) era, serial CAS findings after DES implantation have not been fully elucidated. We investigated the impact of CAS findings after implantation of a polymer-free biolimus A9-coated stent (PF-BCS) or durable polymer everolimus-eluting stent (DP-EES).Methods and Results: We investigated serial CAS and optical coherence tomography (OCT) findings at 1 and 12 months in 99 patients who underwent PF-BCS or DP-EES implantation. We evaluated factors correlated with angioscopic thrombi and yellow plaque, and the clinical impact of both thrombi and yellow plaque at 12 months (BTY). The BTY group included 17 (22%) patients. The incidence and grade of thrombi and yellow plaque decreased from 1 to 12 months. Although no patients had newly appearing thrombi at 12 months, 2 DP-EES patients had newly appearing yellow plaque at 12 months. Multivariable analysis revealed HbA1c, minimum stent area, and adequate strut coverage were significant factors correlated with 12-month angioscopic thrombi, and DP-EESs were significantly correlated with 12-month yellow plaque. However, BTY was not correlated with clinical events.

Conclusions: The management of diabetes, stent area, and adequate stent coverage are important for intrastent thrombogenicity and polymer-free stents are useful for stabilizing plaque vulnerability.

植入药物洗脱支架后 12 个月血管镜血栓和黄色斑块的影响
背景:冠状动脉血管造影(CAS)有两个独特的功能:直接观察血栓和斑块颜色。然而,在最近的药物洗脱支架(DES)时代,DES 植入后的序列 CAS 结果尚未完全阐明。我们研究了植入无聚合物生物利莫司 A9 涂层支架(PF-BCS)或耐久性聚合物依维莫司洗脱支架(DP-EES)后 CAS 结果的影响:我们对 99 名接受 PF-BCS 或 DP-EES 植入术的患者在 1 个月和 12 个月时的连续 CAS 和光学相干断层扫描 (OCT) 结果进行了调查。我们评估了与血管镜血栓和黄色斑块相关的因素,以及12个月时血栓和黄色斑块的临床影响(BTY)。BTY组包括17名(22%)患者。从 1 个月到 12 个月,血栓和黄色斑块的发生率和等级均有所下降。虽然没有患者在 12 个月时出现新的血栓,但有 2 名 DP-EES 患者在 12 个月时出现了新的黄色斑块。多变量分析显示,HbA1c、最小支架面积和足够的支架覆盖面是与 12 个月血管镜血栓相关的重要因素,而 DP-EES 与 12 个月的黄色斑块显著相关。然而,BTY与临床事件无关:结论:糖尿病管理、支架面积和充分的支架覆盖对支架内血栓形成很重要,无聚合物支架有助于稳定斑块的脆弱性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Circulation Journal
Circulation Journal 医学-心血管系统
CiteScore
5.80
自引率
12.10%
发文量
471
审稿时长
1.6 months
期刊介绍: Circulation publishes original research manuscripts, review articles, and other content related to cardiovascular health and disease, including observational studies, clinical trials, epidemiology, health services and outcomes studies, and advances in basic and translational research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信