Norma Mejias Quinteiro, Josilene Fioravanti Dos Santos, Jamil Pedro de Siqueira Caldas, Elenice Valentim Carmona
{"title":"Procedures for a Transpyloric Feeding Tube Inserted Into Newborns and Infants: A Systematic Review.","authors":"Norma Mejias Quinteiro, Josilene Fioravanti Dos Santos, Jamil Pedro de Siqueira Caldas, Elenice Valentim Carmona","doi":"10.1097/ANC.0000000000001172","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Enteral feeding by a transpyloric tube in critically ill infants is indicated when there is a failure in gastric feeding. However, there is a wide variability regarding the insertion technique.</p><p><strong>Purpose: </strong>To perform a systematic review of the methods for inserting a transpyloric feeding tube in newborns and infants.</p><p><strong>Data sources: </strong>Nine databases, without date or language restrictions, accessed in September 2021.</p><p><strong>Study selection: </strong>A systematic review of experimental and nonexperimental studies, according to the \"Patient/problem; Intervention; Comparison; Outcome\" strategy and the \"Preferred Reporting Items for Systematic Reviews and Meta-Analyses\" guidelines. The clinical question was about the measurement and insertion techniques, as well as the success rates of properly placing a transpyloric tube in newborns and infants.</p><p><strong>Data extraction: </strong>Two authors (N.M.Q. and J.F.S.) analyzed 6 observational descriptive prospective studies, all of them published in peer-reviewed indexed medical journals and one in the official journal of the National Association of Neonatal Nurses.</p><p><strong>Results: </strong>The success rate varied between 70% and 100%. There was an important variability in the type of tube, measurement method, and insertion techniques. It was found that the most common strategies to achieve proper positioning were glabella-calcaneal measurements, gastric air insufflation, and right lateral decubitus.</p><p><strong>Implications for practice: </strong>A transpyloric catheter insertion protocol needs to be established in each neonatal unit, according to the literature findings.</p><p><strong>Implications for research: </strong>Randomized controlled studies that evaluate the gastric air insufflation technique and other adjuvant measures could elucidate the knowledge gap concerning the correct positioning of transpyloric tubing in newborns and infants.</p>","PeriodicalId":48862,"journal":{"name":"Advances in Neonatal Care","volume":" ","pages":"374-381"},"PeriodicalIF":1.6000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Neonatal Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ANC.0000000000001172","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/9 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Enteral feeding by a transpyloric tube in critically ill infants is indicated when there is a failure in gastric feeding. However, there is a wide variability regarding the insertion technique.
Purpose: To perform a systematic review of the methods for inserting a transpyloric feeding tube in newborns and infants.
Data sources: Nine databases, without date or language restrictions, accessed in September 2021.
Study selection: A systematic review of experimental and nonexperimental studies, according to the "Patient/problem; Intervention; Comparison; Outcome" strategy and the "Preferred Reporting Items for Systematic Reviews and Meta-Analyses" guidelines. The clinical question was about the measurement and insertion techniques, as well as the success rates of properly placing a transpyloric tube in newborns and infants.
Data extraction: Two authors (N.M.Q. and J.F.S.) analyzed 6 observational descriptive prospective studies, all of them published in peer-reviewed indexed medical journals and one in the official journal of the National Association of Neonatal Nurses.
Results: The success rate varied between 70% and 100%. There was an important variability in the type of tube, measurement method, and insertion techniques. It was found that the most common strategies to achieve proper positioning were glabella-calcaneal measurements, gastric air insufflation, and right lateral decubitus.
Implications for practice: A transpyloric catheter insertion protocol needs to be established in each neonatal unit, according to the literature findings.
Implications for research: Randomized controlled studies that evaluate the gastric air insufflation technique and other adjuvant measures could elucidate the knowledge gap concerning the correct positioning of transpyloric tubing in newborns and infants.
期刊介绍:
Advances in Neonatal Care takes a unique and dynamic approach to the original research and clinical practice articles it publishes. Addressing the practice challenges faced every day—caring for the 40,000-plus low-birth-weight infants in Level II and Level III NICUs each year—the journal promotes evidence-based care and improved outcomes for the tiniest patients and their families. Peer-reviewed editorial includes unique and detailed visual and teaching aids, such as Family Teaching Toolbox, Research to Practice, Cultivating Clinical Expertise, and Online Features.
Each issue offers Continuing Education (CE) articles in both print and online formats.