Comparative evaluation of thermal impact of 980nm diode laser on soft tissue using irrigation and non-irrigation systems: A histomorphometric study.

Q2 Dentistry
Bharmappa Radhika, Sharath Wodeyar Shivaswamy, Amit Walvekar, Kunaal Dhingra, Rashmi Somashekhar Pattanshetty, Raju Shashidara
{"title":"Comparative evaluation of thermal impact of 980nm diode laser on soft tissue using irrigation and non-irrigation systems: A histomorphometric study.","authors":"Bharmappa Radhika, Sharath Wodeyar Shivaswamy, Amit Walvekar, Kunaal Dhingra, Rashmi Somashekhar Pattanshetty, Raju Shashidara","doi":"10.4103/jisp.jisp_218_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Diode laser is one of the most captivating technologies in dental practice. In periodontics, when used at appropriate settings, it possesses the best properties for selective surgical and nonsurgical procedures such as subgingival calculus removal without a thermal change of the root surface, and also provides tissue surface sterilization. However, lasers always produce a certain amount of thermal damage to the soft tissues. Therefore, this study aimed to comparatively evaluate the thermal impact of 980-nm diode laser incisions, when used with irrigation versus nonirrigation systems.</p><p><strong>Materials and methods: </strong>The study was conducted on 24 gingival tissue samples obtained from the goat's mandible and maxilla. The samples were divided into two groups of 12 samples each, and laser incisions were given in 4 power settings, using 980-nm diode laser in super short pulse mode, with and without saline irrigation. Martius Scarlet Blue staining technique was used to prepare the histological slides. Then, slides were examined under a research microscope (Olympus CX 21), and the pictures of the slides were taken by mounting the camera onto the microscope mobile mount. The microscopic images hence obtained were analyzed for the depth and width of the incisions, area of carbonization, necrosis, and reversible damage, using the Digimizer image analysis software.</p><p><strong>Results: </strong>The results of this study demonstrated that the mean incision depth was higher (592.49 ± 180.97, <i>P</i> < 0.05), with less carbonization (25.52 ± 29.21, <i>P</i> = 0.00) and less necrosis (311.63 ± 156.441, <i>P</i> < 0.05) in the laser incisions with irrigation, as compared to the laser incisions given without irrigation system.</p><p><strong>Conclusion: </strong>Within the limitations of this study, it can be concluded that using an irrigation system causes less collateral damage while maintaining the incising efficiency of the diode laser. Further studies with a higher sample size, controlled irrigation systems, and incision techniques are needed to evaluate the efficiency of diode lasers for the clinical explanation of the results.</p>","PeriodicalId":15890,"journal":{"name":"Journal of Indian Society of Periodontology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11232811/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Society of Periodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jisp.jisp_218_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Diode laser is one of the most captivating technologies in dental practice. In periodontics, when used at appropriate settings, it possesses the best properties for selective surgical and nonsurgical procedures such as subgingival calculus removal without a thermal change of the root surface, and also provides tissue surface sterilization. However, lasers always produce a certain amount of thermal damage to the soft tissues. Therefore, this study aimed to comparatively evaluate the thermal impact of 980-nm diode laser incisions, when used with irrigation versus nonirrigation systems.

Materials and methods: The study was conducted on 24 gingival tissue samples obtained from the goat's mandible and maxilla. The samples were divided into two groups of 12 samples each, and laser incisions were given in 4 power settings, using 980-nm diode laser in super short pulse mode, with and without saline irrigation. Martius Scarlet Blue staining technique was used to prepare the histological slides. Then, slides were examined under a research microscope (Olympus CX 21), and the pictures of the slides were taken by mounting the camera onto the microscope mobile mount. The microscopic images hence obtained were analyzed for the depth and width of the incisions, area of carbonization, necrosis, and reversible damage, using the Digimizer image analysis software.

Results: The results of this study demonstrated that the mean incision depth was higher (592.49 ± 180.97, P < 0.05), with less carbonization (25.52 ± 29.21, P = 0.00) and less necrosis (311.63 ± 156.441, P < 0.05) in the laser incisions with irrigation, as compared to the laser incisions given without irrigation system.

Conclusion: Within the limitations of this study, it can be concluded that using an irrigation system causes less collateral damage while maintaining the incising efficiency of the diode laser. Further studies with a higher sample size, controlled irrigation systems, and incision techniques are needed to evaluate the efficiency of diode lasers for the clinical explanation of the results.

使用灌注系统和非灌注系统比较评估 980nm 二极管激光对软组织的热影响:组织形态计量学研究
背景:二极管激光是牙科实践中最吸引人的技术之一。在牙周病学中,如果在适当的环境下使用,它具有选择性手术和非手术治疗的最佳特性,如去除龈下结石,而不会使牙根表面发生热变化,还能对组织表面进行消毒。然而,激光总会对软组织产生一定的热损伤。因此,本研究旨在比较评估 980 纳米二极管激光切口在使用灌洗系统和非灌洗系统时的热影响:研究对象是从山羊下颌和上颌获取的 24 个牙龈组织样本。样本分为两组,每组 12 个样本,使用超短脉冲模式下的 980 纳米二极管激光器,在 4 种功率设置下进行激光切口,分别使用生理盐水灌洗和不使用生理盐水灌洗。采用马氏猩红蓝染色技术制备组织切片。然后,在研究用显微镜(奥林巴斯 CX 21)下观察玻片,并将相机安装在显微镜移动支架上拍摄玻片照片。利用 Digimizer 图像分析软件分析切口深度和宽度、碳化面积、坏死和可逆损伤:研究结果表明,与不使用灌洗系统的激光切口相比,使用灌洗系统的激光切口的平均切口深度更高(592.49 ± 180.97,P < 0.05),碳化面积更小(25.52 ± 29.21,P = 0.00),坏死面积更小(311.63 ± 156.441,P < 0.05):在本研究的局限性范围内,可以得出结论:使用灌洗系统可减少附带损伤,同时保持二极管激光的切口效率。需要进行样本量更大、灌洗系统和切口技术更可控的进一步研究,以评估二极管激光的效率,从而为临床解释研究结果提供依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
87
审稿时长
44 weeks
期刊介绍: The Journal of Indian Society of Periodontology publishes original scientific articles to support practice , education and research in the dental specialty of periodontology and oral implantology. Journal of Indian Society of Periodontology (JISP), is the official publication of the Society and is managed and brought out by the Editor of the society. The journal is published Bimonthly with special issues being brought out for specific occasions. The ISP had a bulletin as its publication for a large number of years and was enhanced as a Journal a few years ago
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信