{"title":"Imaging plate scanners calibration and the attenuation behavior of imaging plate signals","authors":"Nan Bo, Nai-Yan Wang","doi":"10.1088/1674-1056/ad43d4","DOIUrl":null,"url":null,"abstract":"Based on previously reported work, we propose a new method for calibrating image plate (IP) scanners, offering greater flexibility and convenience, which can be extended to the calibration tasks of various scanner models. This method was applied to calibrate the sensitivity of a GE Typhoon FLA 7000 scanner. Additionally, we performed a calibration of the spontaneous signal attenuation behavior for BAS-MS, BAS-SR, and BAS-TR type IPs under the 20±1 °C environmental conditions, and observed significant signal carrier diffusion behavior in BAS-MS IP. The calibration results lay a foundation for further research on the interaction between ultra-short, ultra-intense lasers and matter.","PeriodicalId":10344,"journal":{"name":"Chinese Physics Letters","volume":"22 1","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Physics Letters","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1088/1674-1056/ad43d4","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Based on previously reported work, we propose a new method for calibrating image plate (IP) scanners, offering greater flexibility and convenience, which can be extended to the calibration tasks of various scanner models. This method was applied to calibrate the sensitivity of a GE Typhoon FLA 7000 scanner. Additionally, we performed a calibration of the spontaneous signal attenuation behavior for BAS-MS, BAS-SR, and BAS-TR type IPs under the 20±1 °C environmental conditions, and observed significant signal carrier diffusion behavior in BAS-MS IP. The calibration results lay a foundation for further research on the interaction between ultra-short, ultra-intense lasers and matter.
在之前报告工作的基础上,我们提出了一种校准图像平板(IP)扫描仪的新方法,该方法具有更大的灵活性和便利性,可扩展到各种型号扫描仪的校准任务中。我们采用这种方法校准了 GE Typhoon FLA 7000 扫描仪的灵敏度。此外,我们还对 BAS-MS、BAS-SR 和 BAS-TR 型 IP 在 20±1 °C 环境条件下的自发信号衰减行为进行了校准,并观察到 BAS-MS IP 中存在明显的信号载流子扩散行为。校准结果为进一步研究超短、超强激光与物质之间的相互作用奠定了基础。
期刊介绍:
Chinese Physics Letters provides rapid publication of short reports and important research in all fields of physics and is published by the Chinese Physical Society and hosted online by IOP Publishing.