N Yu Gorbunova, R A Yakovlev, N A Pozdeyeva, N O Mikhailov
{"title":"[First experience of implantation of extended depth of focus intraocular lenses in patients with glaucoma].","authors":"N Yu Gorbunova, R A Yakovlev, N A Pozdeyeva, N O Mikhailov","doi":"10.17116/oftalma202414003170","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluates the effectiveness of implantation of extended depth of focus (EDOF) intraocular lenses (IOL) in patients with cataract and glaucoma.</p><p><strong>Material and methods: </strong>The study included 13 patients (16 eyes) who underwent implantation of the Lentis Comfort EDOF IOL (Teleon Surgical BV, Netherlands). Standard phacoemulsification cataract surgery with IOL implantation was performed in a planned manner after the hypotensive surgery stage in two eyes; a combined procedure was performed in 14 cases. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), near visual acuity, and intraocular pressure (IOP) measured with a Maklakov tonometer were assessed preoperatively, on the first day, and 3-6 months after surgery. Computer perimetry using the 30-2 program and spatial contrast sensitivity (SCS) assessment were also performed preoperatively and at the same follow-up time points.</p><p><strong>Results: </strong>On the first day after surgery, UCVA was 0.53±0.65, BCVA was 0.85±0.45. Near UCVA (at 40 cm) was 0.5±0.14 on the first day after surgery and 0.56±0.18 at 3-6 months. According to computer perimetry data, retinal light sensitivity values increased in all patients in the long-term (-3.1±2.9 dB). SCS values increased for objects of all sizes compared to preoperative values.</p><p><strong>Conclusion: </strong>Implantation of EDOF IOL contributes to improved vision without reducing contrast sensitivity and retinal light sensitivity in patients with concomitant cataract and glaucoma.</p>","PeriodicalId":23529,"journal":{"name":"Vestnik oftalmologii","volume":"140 3","pages":"70-74"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik oftalmologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/oftalma202414003170","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study evaluates the effectiveness of implantation of extended depth of focus (EDOF) intraocular lenses (IOL) in patients with cataract and glaucoma.
Material and methods: The study included 13 patients (16 eyes) who underwent implantation of the Lentis Comfort EDOF IOL (Teleon Surgical BV, Netherlands). Standard phacoemulsification cataract surgery with IOL implantation was performed in a planned manner after the hypotensive surgery stage in two eyes; a combined procedure was performed in 14 cases. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), near visual acuity, and intraocular pressure (IOP) measured with a Maklakov tonometer were assessed preoperatively, on the first day, and 3-6 months after surgery. Computer perimetry using the 30-2 program and spatial contrast sensitivity (SCS) assessment were also performed preoperatively and at the same follow-up time points.
Results: On the first day after surgery, UCVA was 0.53±0.65, BCVA was 0.85±0.45. Near UCVA (at 40 cm) was 0.5±0.14 on the first day after surgery and 0.56±0.18 at 3-6 months. According to computer perimetry data, retinal light sensitivity values increased in all patients in the long-term (-3.1±2.9 dB). SCS values increased for objects of all sizes compared to preoperative values.
Conclusion: Implantation of EDOF IOL contributes to improved vision without reducing contrast sensitivity and retinal light sensitivity in patients with concomitant cataract and glaucoma.
期刊介绍:
The journal publishes materials on the diagnosis and treatment of eye diseases, hygiene of vision, prevention of ophthalmic affections, history of Russian ophthalmology, organization of ophthalmological aid to the population, as well as the problems of special equipment. Original scientific articles and surveys on urgent problems of theory and practice of Russian and foreign ophthalmology are published. The journal contains book reviews on ophthalmology, information on the activities of ophthalmologists" scientific societies, chronicle of congresses and conferences.The journal is intended for ophthalmologists and scientific workers dealing with clinical problems of diseases of the eye and physiology of vision.